• Title/Summary/Keyword: 모달 시험

Search Result 77, Processing Time 0.024 seconds

Parametric Study on 3-way Switch Design Considering Levitation Stability of Maglev Train (자기부상열차의 부상안정성을 고려한 3방향 분기기의 설계 파라미터 연구)

  • Lee, Younghak;Han, Jong-Boo;Lim, Jaewon;Lee, Jong-Min
    • Journal of the Korean Society for Railway
    • /
    • v.19 no.2
    • /
    • pp.135-144
    • /
    • 2016
  • It is essential to lighten the weight of switch girders in order to reduce their costs of manufacturing and make it easier to use them in construction. Lightening the weight of switch is also important to the Maglev 3-way switches system, however, the design variables should be considered very carefully if lightening is to be applied to the system, because these variables are vitally related to the levitation stability. Because Urban Maglev trains have a structure in which train bogie wraps around the guiderail, the adjustment of a girder's height is a possible way to reduce the weight. The safety of the application of this concept is ensured by repeated experiments in a test bed, however, due to a lack of space and budget limits, the design parametric study for the system model can substitute for actual application. The purpose of this paper is to study the design parameters that are concerned with levitation stability while a Maglev train is running on the Maglev 3-way system depending on the weight of the switch girders. In this study, switch girder weight is reduced by adjustment of girder height and girders are and modeled as a flexible body. The effect of the adjustment of girder height on the levitation stability can be analyzed by comparing the velocity of the train when it passes the switch girders, with the lateral gap, and the levitation gap which are obtained from the co-simulation of the Maglev train's dynamics model and flexible switching system. The results of this research will be used to design a Maglev switch.

Damping Characterization of the Double-skin Aluminum Extruded Panels for Rolling Stock Carbody (철도차량 차체용 더블 스킨 알루미늄 압출 패널의 감쇠특성)

  • Kang, Gil-Hyun;Kim, Chul-Su
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.7
    • /
    • pp.3197-3202
    • /
    • 2013
  • When car builder designs the large carbody structure of railway vehicles, it is necessary to optimize the damping characteristics through the analysis of structure borne noise such as sound pressure level(SPL). This paper is a study on the structure borne noise analysis by characterizing the damping of double skin aluminum extruded panels for rolling stock carbody. The normalized SPL was calculated based on the simple source theory using measured mechanical mobility parameters from vibration tests(i.e. point, transfer and modal mobility). The reduced SPL was predicted by using finite element method by applying loss factor of damping material into laminated shell elements. It was found out that the damping material coated on the panels like underframe, which part is seriously affected by vibration during train run, took effect to reduce noise level.

A Study on the Modal Characteristics of a Large-sized Military Truck (군용 대형트럭의 고유 진동 특성에 관한 연구)

  • Suh, Kwon-Hee;Lim, Hyeon-Vin;Song, Bu-Geun;Chang, Hun-Sub;Yoo, Woong-Jae;Oh, Cheol-Jo
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.18 no.6
    • /
    • pp.130-137
    • /
    • 2010
  • Due to test facility and specialty, it is physically difficult to conduct the modal tests of large-sized structures such as truck, bus and airplane. So, in case of a large-sized truck, the mode analysis on a full vehicle model comprised of reliable cabin, frame, and deck has been generally performed. However, the reliability of overall vibrational characteristics of the analytic model has not been fairly guaranteed by the testified models of each subsystem owing to the existence of cab suspension and the nonlinear mounting between a chassis frame and a special deck system. In this paper, a method to find out the modal characteristics of a large-sized military truck is presented. New modal test equipment is developed to set the boundary conditions of three military truck variants as close as a free-free condition. And the mode analysis method using coupled structure and dynamic models is established to consider the above-mentioned dynamic non-linearities of the vehicle itself. The usefulness of the suggested method is verified by comparing with the modal test results. Finally, the modal parameters of the final variant are extracted using the proved analytic method.

Multi-flexible Dynamic Modeling and Wheel Load Analysis of a Rubber Tired Gantry Crane in Container Cargo Working (컨테이너 하역작업 시 갠트리 크레인의 유연다물체 동역학 모델링 및 윤하중 해석)

  • Kim, Jungyun;Kim, Jingon
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.27 no.5
    • /
    • pp.379-384
    • /
    • 2014
  • This article describes the dynamic behaviors of a rubber tired gantry crane(RTGC) under typical load conditions which are used in the design of gantry cranes. In order to investigate the dynamic characteristics of an RTGC, we developed a finite element crane model for its huge structure. The finite element model was validated with the modal test results, e.g., natural frequencies and normal modes. And other components of RTGC were converted into detailed 3D CAD models and finally transformed to rigid body models in a dynamic simulation program ADAMS. The load conditions considered in this paper were a normal operating condition(OP1) and container hanging condition with no external loads. As a result, we could find there was large influence of crane's vibration owing to its structural stiffness and deformation. And the vibration of crane could made the movements of RTGC, which occurs crash or malfunction of crane works.

Modal Parameter Extraction of Seohae Cable-stayed Bridge : I. Mode Shape (서해대교 사장교의 동특성 추출 : I. 모드형상)

  • Kim, Byeong Hwa;Park, Min Seok;Lee, Il Keun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.5A
    • /
    • pp.631-639
    • /
    • 2008
  • This paper reports the mode shapes of Seohae cable-stayed bridge extracted by TDD technique. In order to record total 72 acceleration points in the vertical direction of the bridge deck, a custom made data acquisition system with LAN communication has been especially developed and a set of ambient vibration tests has been conducted. For the measured acceleration responses, total twenty four mode shapes up to 2Hz has been extracted by TDD technique. The extracted mode shapes include many new modes that have not been identified in the current on-line health monitoring system installed in the bridge. It is confirmed that TDD technique is the most effective in extracting the high resolution mode shapes on a particularly long span bridge.

Satellite finite element model updating for the prediction of the effect of micro-vibration (미소진동 영향성 예측을 위한 인공위성 유한요소모델 보정)

  • Lim, Jae Hyuk;Eun, Hee-Kwang;Kim, Dae-Kwan;Kim, Hong-Bae;Kim, Sung-Hoon
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.42 no.8
    • /
    • pp.692-700
    • /
    • 2014
  • In this work, satellite FE (finite element) model updating for the prediction of the effect of micro-vibration is described. In the case of satellites launched in low earth orbit, high agility and more mission accomplishments are required by the customer in order to procure many images from satellites. To achieve the goal, many mechanisms, including high capacity wheels and antennas with multi-axis gimbals have been widely adopted, but they become a source of micro-vibration which could significantly deteriorate the quality of images. To investigate the effect due to the micro-vibration in orbit on the ground, a prediction is conducted through an integrated model coupling the measured jitter sources with FE (finite element) model. Before prediction, the FE model is updated to match simulation results with the modal survey test. Subsequently, the quality of FE model is evaluated in terms of frequency deviation error, the resemblance of mode shapes and FRFs (frequency response functions) between test and analysis.

A Fundamental Study of VIV Fatigue Analysis Procedure for Dynamic Power Cables Subjected to Severely Sheared Currents (강한 전단 해류 환경에서 동적 전력케이블의 VIV 피로해석 절차에 관한 기초 연구)

  • Chunsik Shim;Min Suk Kim;Chulmin Kim;Yuho Rho;Jeabok Lee;Kwangsu Chea;Kangho Kim;Daseul Jeong
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.60 no.5
    • /
    • pp.375-387
    • /
    • 2023
  • The subsea power cables are increasingly important for harvesting renewable energies as we develop offshore wind farms located at a long distance from shore. Particularly, the continuous flexural motion of inter-array dynamic power cable of floating offshore wind turbine causes tremendous fatigue damages on the cable. As the subsea power cable consists of the helical structures with various components unlike a mooring line and a steel pipe riser, the fatigue analysis of the cables should be performed using special procedures that consider stick/slip phenomenon. This phenomenon occurs between inner helically wound components when they are tensioned or compressed by environmental loads and the floater motions. In particular, Vortex-induced vibration (VIV) can be generated by currents and have significant impacts on the fatigue life of the cable. In this study, the procedure for VIV fatigue analysis of the dynamic power cable has been established. Additionally, the respective roles of programs employed and required inputs and outputs are explained in detail. Demonstrations of case studies are provided under severely sheared currents to investigate the influences on amplitude variations of dynamic power cables caused by the excitation of high mode numbers. Finally, sensitivity studies have been performed to compare dynamic cable design parameters, specifically, structural damping ratio, higher order harmonics, and lift coefficients tables. In the future, one of the fundamental assumptions to assess the VIV response will be examined in detail, namely a narrow-banded Gaussian process derived from the VIV amplitudes. Although this approach is consistent with current industry standards, the level of consistency and the potential errors between the Gaussian process and the fatigue damage generated from deterministic time-domain results are to be confirmed to verify VIV fatigue analysis procedure for slender marine structures.