• Title/Summary/Keyword: 모니터링 인자

Search Result 349, Processing Time 0.033 seconds

Peritoneal Protein Loss in Nephrotic Syndrome on Peritoneal Dialysis (복막 투석 중인 신증후군 환자의 복막을 통한 단백 소실)

  • Ahn, Yo-Han;Jung, Eui-Seok;Lee, Se-Eun;Lee, Hyun-Gyung;Lee, So-Hee;Kang, Hee-Gyung;Ha, Il-Soo;Jung, Hae-Il;Choi, Yong
    • Childhood Kidney Diseases
    • /
    • v.13 no.2
    • /
    • pp.189-196
    • /
    • 2009
  • Purpose : The pathophysiologic mechanism of nephrotic syndrome is not yet known clearly. At least in some cases, certain 'circulating factors' are thought to increase the glomerular protein permeability. Considering the systemic effect of the circulating factor on peritoneal membrane, we evaluated the loss of protein through peritoneal membrane in patients on peritoneal dialysis due to the end stage renal disease (ESRD) caused by steroid resistant nephrotic syndrome (SRNS). Methods : We retrospectively reviewed the medical records of 26 pediatric patients on peritoneal dialysis ensued during the period from 2001 to 2007 at our clinic. Twelve patients had SRNS, while 14 patients had ESRD caused by the congenital anomalies of urinary system. Results : While the other parameters including nPNA indicating the adequacy of protein intake were similar between the two groups, serum albumin was lower in SRNS patients than the non-SRNS patients ($3.7{\pm}0.3$ g/dL vs. $4.0{\pm}0.4$ g/dL, P=0.021). Peritoneal protein loss was higher in SRNS patients than in non-SRNS patients ($3,044.4{\pm}837.6\;mg/m^2$/day vs. $1,791.6{\pm}1,244.0\;mg/m^2$/day, P=0.007). The protein permeability of the peritoneal membrane measured by the ratio of total protein concentration in dialysate to plasma was twice as high in SRNS patients as the non-SRNS ($1.06{\pm}0.46%$ vs. $0.58{\pm}0.43%$, P=0.010). After 1 year, peritoneal protein loss increased in both patient groups, but to a significantly greater degree in non-SRNS patient (P=0.023). Conclusion : The results of our study support the notion that in nephrotic syndrome there are some 'circulating factors' with the systemic effect. Since the greater protein loss through peritoneal membrane in SRNS was confirmed in this study, more meticulous nutritional support and close monitoring on the nutrition are required in these patients.

Eutrophication and Freshwater Red-tide Algae on Early Impoundment Stage of Jeolgol Reservoir in the Paikryeong Island, West Sea of South Korea (백령도 절골저수지의 부영양화와 담수적조)

  • Lee, Heung-Soo;Hur, Jin;Park, Jae-Chung;Shin, Jae-Ki
    • Korean Journal of Ecology and Environment
    • /
    • v.39 no.2 s.116
    • /
    • pp.271-283
    • /
    • 2006
  • A systematic water quality survey was conducted in August, 2005 for a drinking water supply reservoir (the Jeolgol reseuoir located in an island), which is at an early stage of impoundment, to investigate the causes of water color deterioration of the reservoir and the clogging of filter beds of a water treatment plant. The reservoir shape was simple and its average depth was 5.5 m, increasing from upreservoir toward the downreservoir end near the dam. Dissolved oxygen (DO) and chloropllyll-a (chi-a) showed a large variation while water temperature had a smaller range. Transparency ranged from 0.6 to 0.9 m (average 0.7 m). The average value of turbidity was 9.3 NTU, ranging from 8.0 ${\sim}$ 12.1 NTU. The transparency and the turbidity appear to be affected by a combination of biological and non-biological factors. The poor transparency was explained by an increase of inorganic colloids and algal bloom in the reservoir. The blockage of the filter bed was attributed to the oversupply of phytoplanktons from the reservoir. The range and the average concentration of chi-a within the reservoir were 31.6 ${\sim}$ 258.9 ${\mu}g\;L^{-1}$, 123.6 ${\mu}g\;L^{-1}$ for the upper layer, and 17.0 ${\sim}$ 37.4 ${\mu}g\;L^{-1}$, 26.5 ${\mu}g\;L^{-1}$ for the bottom layer, respectively. A predominant species contributing the algal bloom was Dinophyceae, Peridinium bipes f. occultatum. The distribution of Peridinium spp. was correlated with chi-a concentrations. The standing crop of phytoplankton was highest in the upreservoir with $8.5\;{\times}\;103\;cells\;mL^{-1}$ and it decreased toward the downresevoir. Synedra of Bacillariophyceae and Microcystis aeruginosa of Cyanophyceae appeared to contribute to the algal bloom, although they are not dominated. It is mostly likely that sloped farmlands located in the watershed of the reservoir caused water quality problems because they may contain a significant amount of the nutrients originated from fertilizers. In addition, the aerators installed in the reservoir and a shortage of the inflowing water may be related to the poor water quality. A long-term monitoring and an integrated management plan for the water quality of the watersheds and the reservoir may be required to improve the water quality of the reservoir.

Evaluation of Standing Tree Characteristics by Development of the Criteria on Grading Hardwood Quality for Oaks Forests in Central Region of Korea (활엽수 입목형질등급 기준 개발을 통한 중부지역 참나무림의 입목특성 평가)

  • Lee, Young Geun;Lee, Sang Tae;Chung, Sang Hoon
    • Journal of Korean Society of Forest Science
    • /
    • v.107 no.4
    • /
    • pp.344-350
    • /
    • 2018
  • This study was carried out to improve the forest management method considering the use of high value added timber in the natural broadleaf forests. For this purpose, the criteria for evaluating the quality grade of standing trees were established and applied to the oak stand in the central region of Korea. The evaluation factors of the grade were bending of stem, branch, stem damage, and other defects. If the logs are divided into 2.1 m units and three logs up to 6.3 m are available, they are classified as Grade I (G-I). If two logs are available, they are classified as Grade II (G-II), If only one log is available, it is classified as Grade III (G-III). When any log is not available as timber, it is classified as Grade IV (G-IV). As a result of applying the grade to the oak stand, G-I was 6.7 %, G-II was 28.0 %, G-III was 38.3 %, and G-IV was 27.0 %. The ratio of standing trees by oak species of higher than G-III was 88.2 % for Quercus acutissima, 88.1 % for Q. variabilis, 83.5 % for Q. serrata, 56.3 % for Q. aliena, and 50.3 % for Q. mongolica, respectively. The G-IV ratio for Q. variabilis and Q. mongolica tended to decrease with increasing diameter at breast height. The order of major defect affecting the grading level was bending of stem > branch > stem damage > other defects. Considering the grade level and oak species distribution, it was concluded possible to produce high quality hardwood timber when we concentrate forest tending techniques on Q. acutissima and Q. variabilis stand. In order to improve the accuracy of grading, it is necessary to continuous complement through the monitoring research for evaluation factors.

Correlation of the Deformation of the Kyphotic Angle with the Fat Infiltration Rate of Multifidus and Erector Spinae in Patients with Acute Osteoporotic Fractures of the Lumbar Spine (급성 골다공증성 요추 골절 환자에서 척추 기립근 및 다열근의 지방침투율과 후만각 변형의 연관 관계)

  • Jun, Deuk Soo;Baik, Jong-Min;Baek, Seung Hyun
    • Journal of the Korean Orthopaedic Association
    • /
    • v.56 no.3
    • /
    • pp.208-214
    • /
    • 2021
  • Purpose: Verifying a reliable predictor of the progression of vertebral deformity in patients with acute osteoporotic fractures of the lumbar spine may be useful. A qualitative analysis of the muscle near the spine was performed using magnetic resonance imaging (MRI), and its correlation with a spinal deformity was determined under the hypothesis that the causes of the kyphotic deformity are associated with muscle reduction in the multifidus and erector spinae. Materials and Methods: The study was performed in a retrospective manner using the electronic medical records of patients who presented to the author's institution between January 2007 and March 2018, and were diagnosed with an acute lumbar fracture. The fat infiltration rates of the multifidus and erector spinae were measured using MRI taken at the time of injury, and the mean value was defined as the total fat infiltration rate (TFI). Based on lateral radiographs of the lumbar spine at the one-year follow-up, the loss of height of the vertebral body, the kyphotic angle and the wedge angle were measured. The statistical significance was confirmed by calculating the Pearson correlation coefficient. Results: One hundred twenty-nine patients, of which 30 were male and 99 were female, were examined. The mean age was 71.28 years. The mean T-score was -3.53±0.79 g/cm2, and the mean fat infiltration was 15.20%±11.99%. TFI was positively correlated with age (R=0.373, p<0.001), compression rate (R=0.369, p<0.001), and Cobb's angle (R=0.386, p<0.001) after a one year follow-up, but negatively correlated with the BMD score (R=-0.252, p=0.004). As the fracture progressed to the lower lumbar level, the compression rate (R=-0191, p=0.030) and wedge angle (R=-0.428, p<0.001) at the time of injury tended to decrease. Conclusion: In patients with osteoporotic vertebral fractures, the fat infiltration rate may be an important predictor of conservative treatment. The prognosis of patients with a high-fat infiltration rate should be explained during patient education, and the patients must be monitored closely through short-term outpatient follow-up.

A Comprehensive Computer Program for Monitor Unit Calculation and Beam Data Management: Independent Verification of Radiation Treatment Planning Systems (방사선치료계획시스템의 독립적 검증을 위한 선량 계산 및 빔데이터 관리 프로그램)

  • Kim, Hee-Jung;Park, Yang-Kyun;Park, Jong-Min;Choi, Chang-Heon;Kim, Jung-In;Lee, Sang-Won;Oh, Heon-Jin;Lim, Chun-Il;Kim, Il-Han;Ye, Sung-Joon
    • Progress in Medical Physics
    • /
    • v.19 no.4
    • /
    • pp.231-240
    • /
    • 2008
  • We developed a user-friendly program to independently verify monitor units (MUs) calculated by radiation treatment planning systems (RTPS), as well as to manage beam database in clinic. The off-axis factor, beam hardening effect, inhomogeneity correction, and the different depth correction were incorporated into the program algorithm to improve the accuracy in calculated MUs. A beam database in the program was supposed to use measured data from routine quality assurance (QA) processes for timely update. To enhance user's convenience, a graphic user interface (GUI) was developed by using Visual Basic for Application. In order to evaluate the accuracy of the program for various treatment conditions, the MU comparisons were made for 213 cases of phantom and for 108 cases of 17 patients treated by 3D conformal radiation therapy. The MUs calculated by the program and calculated by the RTPS showed a fair agreement within ${\pm}3%$ for the phantom and ${\pm}5%$ for the patient, except for the cases of extreme inhomogeneity. By using Visual Basic for Application and Microsoft Excel worksheet interface, the program can automatically generate beam data book for clinical reference and the comparison template for the beam data management. The program developed in this study can be used to verify the accuracy of RTPS for various treatment conditions and thus can be used as a tool of routine RTPS QA, as well as independent MU checks. In addition, its beam database management interface can update beam data periodically and thus can be used to monitor multiple beam databases efficiently.

  • PDF

Diurnal and Seasonal Variations of the Radon Progeny Concentrations in the open Atmosphere and the Influence of Meteorological Parameters (대기중 라돈자핵종 농도의 일일 및 계절적 변화와 기상인자가 미치는 영향)

  • Lee, Dong-Myung;Kim, Chang-Kyu;Rho, Byung-Hwan;Lee, Seung-Chan;Kang, Hee-Dong
    • Journal of Radiation Protection and Research
    • /
    • v.25 no.4
    • /
    • pp.207-216
    • /
    • 2000
  • Continuous measurements of radon progeny concentrations in the open atmosphere and measurements of meteorological parameters were performed in Tajeon, using a continuous gross alpha/beta aerosol monitor and a weather measuring equipment between July 1999 and July 2000. These data were analyzed for half-hourly, daily, and seasonal variations. The distribution of daily averaged equilibrium equivalent radon concentration$(EEC_{Rn})$ had an arithmetic mean value of $11.3{\pm}5.86Bqm^{-3}$ with the coefficient of variation of about 50% and the geometric mean was $10.3Bqm^{-3}$. The $EEC_{Rn}$ varies between 0.83 and $43.3Bqm^{-3}$, depending on time of day and weather conditions. Half-hourly averaged data indicated a diurnal pattern with the outdoor $EEC_{Rn}$ reaching a maximum at sunrise and a minimum at sunset. The pattern of the seasonal variation of the $EEC_{Rn}$ in Taejon had a tendency of minimum concentration occurring in the summer(July) and maximum concentration occurring in the late autumn(November). But the seasonal variation of the $EEC_{Rn}$ is expect to vary greatly from place to place. The outdoor $EEC_{Rn}$ was highly dependent on the local climate features. Particularly the $EEC_{Rn}$an rapidly drops less than $5Bqm^{-3}$ in case of blowing heavily higher than wind speed of $6msec^{-1}$, reversely the days with more than $30Bqm^{-3}$ were at a calm weather condition with the wind speed of lower than $1msec^{-1}$.

  • PDF

GCP Data Acquisition using Image Chip (영상 CHIP을 이용한 지상기준점 정보취득)

  • 손홍규;이재원;허민;김기홍;이준명
    • Proceedings of the Korean Association of Geographic Inforamtion Studies Conference
    • /
    • 2003.04a
    • /
    • pp.349-353
    • /
    • 2003
  • 최근 관심이 증대되고 있는 국토모니터링과 관련하여 기존의 SPOT, IRS, KOMPSAT, LANDSAT 등의 중ㆍ저해상도 위성영상과 IKONOS 등의 고해상도 위성영상을 이용하여 국토의 변화를 탐지하고자 하는 시도가 활발히 진행되고 있다. 이 때 영상의 기하보정은 필수적인 과정이며 영상의 기하보정시 기준점을 취득하는 과정에 많은 시간과 작업비용이 소요된다. 현재 기준점 취득은 수치지도 등을 통해 기존의 지상기준점을 이용하는 방법과 GPS를 이용한 현지 측량방법이 활용되고 있는데 동일지역에 대해 매번 사업 때마다 수행되고 있는 실정이다. 따라서 이러한 과정을 보다 효율적으로 수행하기 위한 하나의 방안으로 본 연구에서는 image chip을 이용하여 GCP를 취득하고 이를 데이터베이스로 구축하여 기존의 작업을 자동화, 체계화하고자 하였다. 이를 통하여 중복측량 방지와 데이터의 균질성을 기할 수 있었다. Image Chip의 영상 정합을 위해서는 상관계수법과 최소제곱정합법을 이용하여 부영상소 단위까지 정합결과를 얻을 수 있었으며 위성의 header 정보로부터의 영상의 표정각과 입사각에 대한 정보를 이용하여 축척과 회전요소를 고려함으로써 영상 정합시 보다 정확한 기준점 정보를 취득할 수 있었다. 또한, 이종 센서간 영상정합 가능성에 대해서 연구한 결과 KOMPSAT과 SPOT간에는 신뢰할 만한 수준의 정합 결과를 얻을 수 있었으나 고해상도 영상의 경우에는 항공사진과 IKONOS의 영상 정합시 센서의 방사학적 특성의 차이로 신뢰할 안한 결과를 얻을 수 없었다. 영상 정합시 정확도에 영향을 미치는 인자들에 관한 실험 결과 센서의 파장, 계절, Chip 영상의 크기 등이 큰 영향을 미쳤으며 영상정합을 위해 영상 GCP를 데이터베이스에서 검색할 때 이에 대한 고려가 우선적으로 이루어져야 할 것으로 사료된다.n of hub-and-spoke system, integration of logistics bases, introduction of (automatic) parking building, diversification of transportation mode, and etc. At the same time, we constructed three practically executable scenarios based on those ideas. The first is "Center Hub" scenario, the second is "Metropolitan Hub" scenario. The third and last scenario is "Regional Consolidation of Warehouses (distribution centers)".f worldly desire' and 'cordiality' that one could be deserved his diligency becoming a part of the harmonious idealistic living place. Fourthly, on the character of story teller. Originally he is a incomer of "Gang-Ho" from real world. so that reason, he is showing dualism not to deny the loyalty oath to his king, while he intends to satisfy with the life in "Gang- Ho" separating himself from real world. As a gentry, at that time, the loyalty oath is inevitable one and that is found from wr

  • PDF

Analysis of Temporal and Spatial Red Tide Change in the South Sea of Korea Using the GOCI Images of COMS (천리안 위성 GOCI 영상을 이용한 남해안의 시공간적 적조변화 분석)

  • Kim, Dong Kyoo;Yoo, Hwan Hee
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.22 no.3
    • /
    • pp.129-136
    • /
    • 2014
  • This study deals with red tide detection by using the remote sensing imagery from the Geostationary Ocean Color Imager (GOCI), the world's first geostationary orbit satellite, around the southern coast of Korea where the most severe red tide occurred recently. The red tide zone was determined by the available data selection from the GOCI imagery during the period of red tide occurrence and also the severe red tide zone was detected through the spatial analysis by temporal change out of the red tide zone. This study results showed that the coast in the vicinity of the Hansan and Yokji in Tongyeong-si was classified into the severe red tide zone, and that the red tide was likely to spread from the coast of Hansan and Yokji to the one of Sanyang-eub. In addition, the comparative analysis between the area of red tide occurrence, the prevention activities of Gyeongsangnam-do provincial government and the amount of the damage cost over time showed close correlation among them. It is still early to conclude that the study is showing the severe red tide zone and the spread path exactly due to various factors for red tide occurrence and activities. In order to improve the reliability of the results, the more data analysis is required.

제초제저항성 GM 들잔디(JG21)의 포장시험을 통한 생물학적 안전성평가

  • Bae, Tae-Ung;Gang, Hong-Gyu;Jeong, Ok-Cheol;Song, In-Ja;Seon, Hyeon-Jin;Go, Seok-Min;Im, Pyeong-Ok;Song, Pil-Sun;Lee, Hyo-Yeon
    • Proceedings of the Plant Resources Society of Korea Conference
    • /
    • 2010.10a
    • /
    • pp.3-3
    • /
    • 2010
  • GM 들잔디의 환경위해성평가는 유전자변형생물체의 국가간이동등에 관한 법률 (2008년)에 안전관리 및 시험평가가 수행되었다. 일반적으로 GM 작물의 환경위해성평가는 도입 유전자의 안정적 발현여부, 일반적으로 사용되어온 식물과의 실질적 동등성, 화분비산에 의한 유전자이동성 검정, GM재배작물 주변 환경에 미치는 영향, GM작물 및 유전자의 인체 및 동물에 대한 안전성 평가, 위해성 관리 등이 있다. 본 발표에서는 제초제저항성 GM 들잔디를 실용화 하기위한 환경위해성평가의 내용을 소개하기 위하여 GM 들잔디의 안전성평가를 수행한 포장시험에 대해서 간략히 발표하고자 한다. GM 들잔디는 제초제저항성 유전자가 식물체내에 1개의 복제수를 갖으며, 후세대에서도 안정적으로 발현되었다. 또한 TAIL PCR을 통한 도입 유전자의 삽입 부위를 확인하였고, 주변염기서열을 이용한 JG21 들잔디 만의 특이적 염기서열을 얻었다. GM 들잔디의 실질적 동등성검정은 격리온실 수준과 격리포장 수준에 생물학적, 화학적 특성을 조사하였고, 일반 들잔디와 큰 차이가 없음을 확인하였다. GM 들잔디의 화분은 일광조건하에서 약 1시간 이내에 불활성 되었고, 실내의 실온조건에서는 3시간까지 활성이 유지되었다. GM 들잔디 재배포장 ($12m{\times}6m$ 크기)으로부터 화분비산 밀도는 3 m 이내에서 높게 나타났고, 9 m 이상의 거리에서는 낮은 빈도로 일정하게 나타났다. 화분비산에 의한 GM 들잔디 유전자이동성은 근접거리에서 약 15%가 관찰되었고, 반경 3 m 이내에서 거리에 따라서 2 ~ 0.12%의 유전자이동성이 관찰되었다. 각각의 시험모형에 따른 GM 들잔디와 일반들잔디 간의 교잡율을 조사한 결과 들잔디 교잡율은 GM 잔디의 면적과 거리에 의존적이었고, GM 들잔디 면적에 따라서 6-21%의 교잡율이 나타났다. GM들잔디의 인체위해성평가는 독성 및 알레르기 반응성을 검정하였고, 도입유전자 산물인 PAT 단백질은 독성 및 알레르기 반응성이 없음이 알려져 있다. 본 연구에서는 GM들잔디의 독성 및 알레르기 반응성을 검토한 결과 아플라톡신 등의 독성은 검출되지 않았으나, GM과 일반 들잔디 모두에서 화분 알레르기 반응성이 양성으로 나왔다. 그러나 GM들잔디에 도입된 유전자에 의한 알레르기 반응이 아닌 일반들잔디 화분에 가진 알레르겐에 의한 반응성이라 할 수 있다. GM들잔디의 비의도적 방출가능성을 조사하기위하여 시험포장외부의 자연환경에 대해서 환경모니터링을 수행한 결과 GM 들잔디의 유출 및 유전자이동 의한 제초제저항성 들잔디는 나타나지 않았다.

  • PDF

Brightness Value Comparison Between KOMPSAT-2 Images with IKONOS/GEOEYE-1 Images (KOMPSAT-2 영상과 IKONOS/GEOEYE-1 영상의 밝기값 상호비교)

  • Kim, Hye-On;Kim, Tae-Jung;Lee, Hyuk
    • Korean Journal of Remote Sensing
    • /
    • v.28 no.2
    • /
    • pp.181-189
    • /
    • 2012
  • Recently, interest in potential for estimating water quality using high resolution satellite images is increasing. However, low SNR(Signal to Noise Ratio) over inland water and radiometric errors such as non-linearity of brightness value of high resolution satellite images often lead to accuracy degradation in water quality estimation. Therefore radiometric correction should be carried out to estimate water quality for high resolution satellite images. For KOMPSAT-2 images parameters for brightness value-radiance conversion are not available and precise radiometric correction is difficult. To exploit KOMPSAT-2 images for water quality monitoring, it is necessary to investigate non-linearity of brightness value and noise over inland water. In this paper, we performed brightness value comparison between KOMPSAT-2 images and IKONOS/GeoEye-1, which are known to show the linearity. We used the images obtained over the same area and on the same date for comparison. As a result, we showed that although KOMPSAT-2 images are more noisy;the trend of brightness value and pattern of noise are almost similar to reference images. The results showed that appropriate target area to minimize the impact of noise was $5{\times}5$. Non-linearity of brightness value between KOMPSAT-2 and reference images was not observed. Therefore we could conclude that KOMPSAT-2 may be used for estimation of water quality parameters such as concentration of chlorophyll.