A Study on the Three-Dimensional Steady State Temperature Distributions and BOR Calculation Program Development for the Membrane Type LNG Carrier (Membrane Type LNG선의 3차원 정상상태 온도분포 및 BOR 계산 프로그램 개발에 관한 연구)

  • 이정혜
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.23 no.2
    • /
    • pp.140-149
    • /
    • 1999
  • This study is on the development of the computer program that calculates a 3-D hull temperadistribution and analyzes BOR(Boil off rate) to be important to the heat design of a membrane type LNG carrier. The quarter of a tank is taken as an calculation model. And the thermal conductivity of insulation is assumed to be the function of a temperature. In the present steady state calculation, the temperature of LNG in a cargo tank is assumed to be -$162^{\circ}C$ and the air temperature of a cofferdam, to be +$5^{\circ}C$. The lowest air temperature in compartments is calculated as $21.39^{\circ}C$ under the USCG condition ($T_{air}=-18^{\circ}C,\;T_{sw}=O^{\circ}C)$ and B.O.R value is O.0977%/day under the maximum boil-off condition, IMO IGC ($T_{air}=45^{\circ}C,\;T_{sw}=32^{\circ}C$), which satisfies the requirement by KOGAS. The calculated temperature distribution over tank panels at each condition is maximum 3% less than GTT's results. From the results of this study, it can be concluded that the present design of LNG cargo tank satisfies the requirement by KOGAS.