• Title/Summary/Keyword: 맥동소음

Search Result 97, Processing Time 0.025 seconds

A Study on Influence of High Pressure Hose on Automotive Power Steering Interior Noise Using Frequency Analysis (유압식 자동차 동력조향장치 고압호스가 실내소음에로 미치는 영향의 주파수 분석을 통한 연구)

  • 전승경;신재윤;황호준
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.13 no.2
    • /
    • pp.108-115
    • /
    • 2003
  • High pressure hose having tuning cables, called Resonator hose is frequently used to attenuate pressure ripple generated by the pump for reducing the vehicle interior noise. A number of studios have been conducted on the resonator hose and its analytical models. However, there are few studies which deal with the influence of resonator hose on vehicle interior noise because the most of studies were focused on transmission loss of the resonator hose. This paper presents NVH test results of power steering system and frequency analysis results. In the frequency analysis, both the relations between vibration, pressure ripple and vehicle interior noise and also the design parameters of high pressure hose influencing on vehicle Interior noise were discussed. The test was done for various high pressure hose specimens in full turn condition.

Hydraulic Pulsation and Noise Reduction using the Helmholtz Attenuator (헬름홀츠 감쇠기를 응용한 유압시스템의 유압맥동 및 소음 최소화 연구)

  • 김동현;이대옥;최근국
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1997.04a
    • /
    • pp.614-619
    • /
    • 1997
  • The hydraulic pressure pulsation has on the effected on the acoustic nosie and control performance of the hydraulic-servo system. The Helmholtz attenuator introduction on the hydraulic line is an efficient device to reduce the hydraulic pulsation. The salient feature of causing hydraulic pulsation and the frequency characteristics of Helmholtz attenuator are studied. The hydraulic filter design parameters such as the locating position, connecting orifice area and accumulator volume are mathematically analyzed. The instrumental works are carried out with the remarkable reduction of the hydraulic pressure pulsation magnitude and the acoustic noise level.

  • PDF

Acoustic Noise Reduction of A SRM for Fan in Air conditioner (에어컨 팬 모터용 SRM의 소음 저감)

  • Lee, Dong-Il;Shin, Hyoun-Jeong;Lim, Jun-Young;Han, Seung-Do
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11b
    • /
    • pp.816-821
    • /
    • 2002
  • It is getting more important that energy efficiency and manufacturing cost of the electric motor in appliance. The SRM has been alternative choice. But acoustic noise and harshness in this motor was widely known. So this paper had been studied on the noise reduction of a SRM in air conditioner. This works include some parameters regarding to blown noise sources like a reluctance torque ripple, air gap eccentricity, Especially, it was focused on dynamic characteristics of the system based on mechanical viewpoint. It came to successful results. Besides, this gave us a validity of phase excitation in experimental measurements.

  • PDF

Study on Low Frequency Characteristics of Rotary Compressor (로터리 압축기 저주파 특성에 관한 연구)

  • Kwon, Byoung-Ha;Park, Sin-Kyu;Hwang, In-Soo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11b
    • /
    • pp.857-862
    • /
    • 2002
  • Compressor is a major noise source of air-conditioner. Especially, its low frequency band noise below 1000Hz is very important because it will not be attenuated by passing through the cover panel and heat exchanger in air-conditioner. The factors affecting the low frequency band noise are studied by geometric similarity along with several experiments, and the low frequency noise is closely related with the discharge holes of muffler as well as the cavity of lower shell. The low frequency band noise is significantly reduced by proposed designs.

  • PDF

Development of a Low Noise and High Efficiency Rotary Compressor by a New Muffler (신규 저소음 및 고효율 머플러 적용 회전식 압축기 개발)

  • Jarng, In-Sun;Kim, Bong-Jun;Youn, Young;Sung, Choon-Mo;Lee, Seung-Gap
    • 유체기계공업학회:학술대회논문집
    • /
    • 2004.12a
    • /
    • pp.533-539
    • /
    • 2004
  • The rotary compressor is widely used for the air conditioner because it is efficient and compact. In recent, the need for silent and efficient compressors is much stronger than the past. The new type muffler was invented to reduce noise level and to improve efficiency. The new type muffler that has two side discharge holes and dome shape represents much lower overall noise level, especially noise levels around 1kHz than the old type one that has one center discharge hole In acoustic spectra. Also it has higher air conditioner efficiency by lower oil discharging amount of a compressor than old type one that has rectangular shape and two side discharge holes. The noise reduction and efficiency improvement effects of the new type muffler were verified by tests for rotary compressors and air conditioners.

  • PDF

Examination on High Vibration and Branch Vent Pipe's Failure of Complex Piping System Suppling Condensate-Water in Power Site (발전소 복수 공급 배관계의 고진동과 분기 배기배관의 절손 규명)

  • Kim, Yeon-Whan
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2010.10a
    • /
    • pp.380-384
    • /
    • 2010
  • A disturbance flow at piping bands and discontinuous regions such as a valve, a header has a intense broadband internal pressure field and a sound field which are propagated through the piping system The fields becomes the source of a vibration of this piping system. Intense broadband disturbance flow at a discontinuous region such as elbows, valves or headers generates an acoustical pulsation. The pulsation becomes the source of structural vibration at the piping system. If it coincides with the natural frequency of the pipe system, excessive vibration results. High-level vibration due to the pressure pulsation affects the reliability of the plant piping system. This paper discusses the high vibration and the branch vent pipe's failure of condensate-water supply piping system due to the effect of acoustical pulsations by flow turbulence from the flow control valves of globe type in a power site.

  • PDF

Vibration and Stress Analysis for Reactor Vessel Internals of Advanced Power Reactor 1400 by Pulsation of Reactor Coolant Pump (원자로냉각재펌프 맥동에 대한 APR1400 원자로내부구조물의 진동 및 응력 해석)

  • Kim, Kyu-Hyung;Ko, Do-Young;Kim, Sung-Hwan
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.21 no.12
    • /
    • pp.1098-1103
    • /
    • 2011
  • The structural integrity of APR1400 reactor vessel internals has been being assessed referring the US Nuclear Regulatory Commission regulatory guide 1.20, comprehensive vibration assessment program. The program is composed of a vibration and stress analysis, a vibration and stress measurement, and an inspection. This paper covers the vibration and stress analysis on the reactor vessel internals by the pulsation of reactor coolant pump. 3-dimensional models to calculate the hydraulic loads and structural responses were built and the pressure distributions and the structural responses were predicted using ANSYS. This paper presents that APR1400 reactor vessel internals have enough structural integrity against the pulsation of reactor coolant pump as the peak stress of the reactor vessel internals is much lower than the acceptance limit.

A Study on the Vibration Phenomena of the Duct-fan Systems in Fossil Fueled Boilers : Inlet Vortex Induced Excessive Vibration (화력 발전용 보일러 덕트-홴 시스템의 진동현상에 대한 연구 : 입구측 와류에 의한 과대진동 사례)

  • 김철홍;주영호
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.13 no.3
    • /
    • pp.194-201
    • /
    • 2003
  • During the operation, fatigue failures and cracks of duct plate due to excessive duct vibration occurred in a fan-duct system of fossil fueled boilers. We measured static pressure variation (pressure pulsation) in the outlet, and also measured vibration at the outlet duct of a centrifugal fan. It was found that strong pressure pulsation caused by the inlet vortex occurred in inlet vane of centrifugal fan in the middle range of vane opening. Thus, excessive duct vibration is caused by strong pressure pulsation. In this Paper, it is shown that the frequency and amplitude of pressure pulsation depend mainly on vane opening and are compared with duct vibration. Also, effective solution for reducing pressure pulsation and vibration are presented.

Development of CAE tool for reducing vibration of pipe-mount system conveying fluid (유동이 있는 배관-마운트 계의 진동저감설계 CAE Tool개발)

  • Lee, Seong-Hyeon;Jeon, Su-Hong;Jeong, Weui-Bong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.11a
    • /
    • pp.472-473
    • /
    • 2008
  • In this research, the finite element model is formulated taking into consideration of the effects of the fluid flow in a pipe. The characteristic of vibration is presented using mass, damping and stiffness matrix in the finite element equation of this pipe system. The displacement distribution of pipe system caused by fluid force is discussed. The method for optimizing the location of mount and the value of mount stiffness to reduce the vibration of pipe system is introduced.

  • PDF

The Vibration Analysis of Snubber for Reciprocating Type Hydrogen Compressor (왕복동식 수소 압축기용 완충기 진동 특성 분석)

  • Kim, H.J.;Jang, Y.S.;Cho, S.W.;Choi, B.K.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.53-56
    • /
    • 2007
  • The reciprocating type hydrogen compressor is occurred by the pulsation from the mechanism and this pulsation is make much noise and vibration. Therefor snubber is installed for pulsation decreasing. The five type snubber models were designed for increasing pulsation amplitude reduction and decreasing pressure loss in snubber considering output pipe location as design value. And the pressure flued analysis is carried by CFD. In this paper, each type snubber according CFD result are analyzed by the MSC/NASTRAN to identify the vibration characteristic of each type. The vibration results are compared with CFD results.

  • PDF