미니돼지에서 발치 후 즉시 임플란트 매식시 치경부 표면처리가 골재생에 미치는 효과 (THE EFFECT OF SURFACE TREATMENT OF THE CERVICAL AREA OF IMPLANT ON BONE REGENERATION IN MINI-PIG)

  • 조진용;김영준;유민기;국민석;오희균;박홍주
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제34권3호
    • /
    • pp.285-292
    • /
    • 2008
  • Purpose: The present study was performed to evaluate the effect of surface treatment of the cervical area of implant on bone regeneration in fresh extraction socket following implant installation. Materials and methods: The four minipigs, 18 months old and 30 kg weighted, were used. Four premolars of the left side of both the mandible and maxilla were extracted. ${\phi}$3.3 mm and 11.5 mm long US II plus implants (Osstem Implant co., Korea) with resorbable blasting media (RBM) treated surface and US II implants (Osstem Implant co., Korea) with machined surface at the top and RBM surface at lower portion were installed in the socket. Stability of the implant was measured with $Osstell^{TM}$ (Model 6 Resonance Frequency Analyser: Integration Diagnostics Ltd., Sweden). After 2 months of healing, the procedures and measurement of implant stability were repeated in the right side by same method of left side. At four months after first experiment, the animals were sacrificed after measurement of stability of all implants, and biopsies were obtained. Results: Well healed soft tissue and no mobility of the implants were observed in both groups. Histologically satisfactory osseointegration of implants was observed with RBM surface, and no foreign body reaction as well as inflammatory infiltration around implant were found. Furthermore, substantial bone formation and high degree of osseointegration were exhibited at the marginal defects around the cervical area of US II plus implants. However, healing of US II implants was characterized by the incomplete bone substitution and the presence of the connective tissue zone between the implant and newly formed bone. The distance between the implant platform (P) and the most coronal level of bone-to-implant contact (B) after 2 months of healing was $2.66{\pm}0.11$ mm at US II implants group and $1.80{\pm}0.13$mm at US II plus implant group. The P-B distance after 4 months of healing was $2.29{\pm}0.13$mm at US II implants group and $1.25{\pm}0.10$mm at US II plus implants group. The difference between both groups regarding the length of P-B distance was statistically significant(p<0.05). Concerning the resonance frequency analysis (RFA) value, the stability of US II plus implants group showed relatively higher RFA value than US II implants group. Conclusion: The current results suggest that implants with rough surface at the cervical area have an advantage in process of bone regeneration on defect around implant placed in a fresh extraction socket.

지르코니아 임플란트 지대주와 티타늄 임플란트 지대주의 삼차원적 유한요소응력분석 (Three-Dimensional Finite Element Analysis for Comparison between Titanium Implant Abutment and Zirconia Implant Abutment)

  • 윤미정;김창섭;정창모;서승우
    • 구강회복응용과학지
    • /
    • 제27권1호
    • /
    • pp.51-61
    • /
    • 2011
  • 최근 심미 보철을 위해 높은 강도와 정밀도를 가지면서 동시에 자연치와 유사한 상아질 색을 구현할 수 있는 세라믹 계열의 지르코니아 임플란트 지대주가 보철 재료로서 각광을 받고 있다. 이에 본 연구에서는 삼차원적 유한요소응력분석을 이용하여 기존의 티타늄 소재의 임플란트 지대주와 지르코니아 소재의 임플란트 지대주의 응력분포비교를 통해 지르코니아 임플란트 지대주의 기계적 안정성을 간접적으로 확인하고자 하였다. 악골에 식립된 internal conical joint type과 external butt joint type의 임플란트 매식체에 티타늄 임플란트 지대주 또는 지르코니아 임플란트 지대주를 지대주 나사로 연결하고 상부에 금합금관을 장착하는 유한요소모형을 설계하였다. 교합면 중심으로부터 3mm 편측에 수직 방향으로 250N의 하중을 인가하여 교합력에 의해 임플란트 지대주에서 발생하는 등가응력분포를 분석하였다. 유한요소분석결과 지르코니아 임플란트 지대주와 티타늄 임플란트 지대주의 응력 분포는 유사하게 관찰되었으나 최대등가응력은 임플란트 연결 방식에 상관없이 티타늄 임플란트 지대주에 비해 지르코니아 임플란트 지대주가 약 15% 정도 높게 나타났다. 그럼에도 불구하고 티타늄에 비해 지르코니아의 더 높은 기계적 강도를 고려해 볼 때 임상에서도 기존의 티타늄 임플란트 지대주와 마찬가지로 지르코니아 임플란트 지대주도 임상적인 기계적 안정성을 가질 것으로 생각된다.

동종이식골의 탈회정도가 이소성 골형성유도에 미치는 영향 (EVALUATION OF ECTOPIC BONE FORMATION EFFECT BY DECALCIFIED DEGREE OF ALLOGRAFTS)

  • 윤홍식;진병로;신홍인
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제20권2호
    • /
    • pp.139-147
    • /
    • 1998
  • 동종 이식골 내의 탈회 정도에 따른 잔존 칼슘치가 이소성 골형성능에 미치는 영향을 파악하고자 Sprague-dowley계 백서에서 채취한 경골 및 대퇴골의 골간부를 0.5cm 크기로 절단하여 부착 연조직은 제거한 다음, 초음파 세척장치를 이용하여 $60^{\circ}C$ 0,6N HCl용액으로 5분, 10분, 15분, 20분, 25분, 30분, 35분, 40분간 각각 처리하여 탈회 동종 이식골을 준비하였다. 이때 탈회시간에 따른 시편의 무게를 측정하였고, 각 탈회용액으로부터 1cc를 취한 다음 Sigma사의 진단용 칼슘치 측정kit를 이용하여 spectrophotometer로 600nm 파장하에서 칼슘치를 측정하였다. 그리고 탈회 정도에 따른 이식골편의 골형성 유도능을 확인하기 위하여 24마리의 Sprague-dowley계 백서를 탈회시간별로 8군으로 나누어 배부에 0.5cm 크기로 4군데의 피하낭을 형성한후 각각의 처리된 탈회 이식골편을 이식하였다. 매식된 동종 이식골편들을 술후 1, 2, 3주째 채취하여 통법에 따라 H&E염색 표본을 제작하여 광학현미경으로 관찰하였다. 이상의 실험에서 다음과 같은 결과를 얻었다. 1. 탈회 30분까지의 용출되는 칼슘 농도 변화는 평균 15.91mg/ml로, 탈회 20분 이후에 평균 99.65%의 탈회정도를 보였다. 2. 동종골 무게 변화량은 탈회시작 25분까지 뚜렷한 무게변화를 보였으나, 그 이후에는 변화의 정도가 미약하였다. 3. 탈회된 이식 통종골에의한 이소성 골형성 유도능 비교에서 20분에서 30분간 탈회된 군에서 가장 양호하였고 그 외의 군에서는 그 정도가 열등하였다. 이상의 결과는 탈회된 동종골에 있어 골형성 유도능을 극대화하기 위해서는 골기질내 무기성분의 완전한 탈회가 선행되어야 하며, 탈회골 기질의 변성이 최소화되어야 함을 시사한다.

  • PDF

골다공증 유도 백서 경골에 티타늄 임플랜트 매식 시 지방조직유래 줄기세포 주입과 저출력 초음파 적용이 골치유에 미치는 영향 (Effect of Low Intensity Pulsed Ultrasound with Adipose-Derived Stem Cells on Bone Healing around a Titanium Implant in Tibia of Osteoporosis-Induced Rats)

  • 이광호;최연식;신상훈;정인교;김규천;김철훈;김욱규
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제33권3호
    • /
    • pp.199-209
    • /
    • 2011
  • Purpose: Osteoporosis, is a major health problem for the elderly and post-menopausal women and shown to alter the properties of bone as well as impair bone healing around titanium implants in both human and animals. The objective of this study was to examine the effect of LIPUS with adipose-derived stem cells on the healing process around a titanium implant in rats with osteoporosis. Methods: Sixteen osteoporosis-induced rats were divided into two groups: an adipose-derived stem cell injected with Low Intensity Pulsed Ultrasound (LIPUS) application group and a control group. Titanium screw implants (diameter, 2.0 mm: length, 3.5 mm, Cowell Medi, Korea) were placed into both tibia of 16 rats, on 8 rats as the control group and the other 8 rats as the experimental group. Rats were sacrificed at different intervals from 1, 2, 4 and 8 weeks after implantation for histopathologic and immunohistochemical analyses. Results: Histopathological analysis revealed newly formed bone in experimental group earlier than that in control group. Especially at 1 week after implantation, more amounts of new bone matrix and collagen around the implant in the experimental group were seen compared with the control group. Immunohistochemical analysis showed that the levels of osteoprotegerin (OPG) expression in the experimental group were increased at early stages compared with that of control group until 2 weeks after implantation. But after 2 weeks, the expression level of OPG similar in both groups. The expression levels of receptor activator of nuclear factor kB ligand (RANKL) were stronger in the experimental group than the control group until 2 weeks after implantation. After 4 weeks, expression of RANKL in experimental group was similar to the control group. Conclusion: The results of this study suggest that LIPUS with Adipose-Derived Stem Cells in implantation could promote bone healing around titanium implants in rats with osteoporosis.

당뇨유도 백서 경골에 티타늄 임플란트 매식 시 저출력 초음파 적용이 골치유에 미치는 영향 (Effect of Low-Intensity Pulsed Ultrasound on Bone Healing around Titanium Implant in Tibia of Diabetes Mellitus Induced Rats)

  • 서영교;김욱규;박상준;이수운;김용덕;황대석
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제34권3호
    • /
    • pp.163-172
    • /
    • 2012
  • Purpose: Diabetes mellitus (DM) has been shown to alter the properties of the bone and impair bone healing around a titanium implant. The aim of this study is to investigate whether the low-intensity pulsed ultrasound (LIPUS), which has been known to stimulate the bone healing, improve the osseointegration of the titanium implant in tibia of DM-induced rats. Methods: 16 rats were received streptozotocin (60 mg/kg) for inducing diabetes. A total number of 32 titanium implants were placed bilaterally into both tibiae of these rats. The right tibia of each rat received LIPUS application (10 min/day) during 7 days post-operation, while the left side received no treatment. The study was carried on for six weeks and the rats were sacrificed at 1, 2, 4, and 6 weaks postoperatively (4 rats for each week) for histomorphometric and histologic analysis. Bone-implant contact and bone area were measured. Comparisons between the groups were made using statistical analysis on histomorphometric analysis. Results: The histomorphometry parameters showed that the bone-implant contact and the bone area values have decreased in the late osseointegration periods (4, 6 weeks) compared to the early osseointegration periods (1, 2 weeks) in both two groups. The bone-implant contact values of the LIPUS group were somewhat higher than those of controls at 1, 2 weeks, but the difference was not statistically significant. The bone area values of the LIPUS group were also higher than those of controls at 1, 2 weeks, but the difference was not statistically significant as well. Conclusion: Results of this study indicate that LIPUS may have positive effects on early osseointegration but could not improve the long term stability of dental implants.

가토의 대퇴부에 Calcium Metaphosphate로 코팅된 임플란트 매식후 골유착에 관한 비교 연구 (Comparative Study on Osseointegration of Calcium Metaphosphate (CMP) Coated Implant to RBM Implant in the Femur of Rabbits)

  • 강영주;김기현;이재열;이주민;안상욱;송진우;정유진;신상훈
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제32권6호
    • /
    • pp.511-520
    • /
    • 2010
  • Purpose: This study was conducted in order to compare the efficacy of osseointegration of three different calcium metaphosphate (CMP) coated implants in the rabbit's femur. Materials and Methods: Twenty four rabbits and three different type of CMP coated implants and RBM implants were used in this study. The animals were divided into 4 groups on the basis of implant surface characteristics. Two implants were installed into the condyle of femur of each rabbits. The animals were sacrificed at 2 and 4 weeks after installation. The undecalcified specimens were prepared for histological, radiological examination and histomorphometric analysis of implant-bone contact ratios (BIC) and bone area ratio (BA). Results: Two implants were failed to osseointegrate and implant success rate was 95.2%. There were not any significant inflammatory response in all groups. Fluorescent image at 4 weeks shows that remodeling is slower in RBM group than CMP group. CMP III showed more active remodeling than CMP I, II. In histomorphologic analysis, BIC ratio at 2 weeks was lower than 4 weeks. Conclusion: The results suggest that the ratios of CMP coated implants were higher than that of RBM control group but there is no significantly difference between RBM group and CMP group. In conclusion, CMP coated implant had more clinical availability than RBM implants.

임플랜트 전산화단층사진에서 하악의 위치와 gantry각의 변화가 임플랜트 매식로 평가에 미치는 영향에 관한 연구 (The effect of mandibular position and gantry angle on the evaluation of implant site with implant CT)

  • 이설미;안창현;최항문;허민석;이삼선;최순철;박태원
    • Imaging Science in Dentistry
    • /
    • 제32권1호
    • /
    • pp.35-39
    • /
    • 2002
  • Purpose: The altered gantry angle during scanning for some multiplanar reconstruction CT program (CT/MPR) may cause distortion of the image. The aim of this study was to ascertain whether there is a image distortion in a reformatted image when the gantry and the object are equally inclined using ToothPix and DentaScan program. Materials and Methods: A resin block model with four cylindrical holes and a human dry mandible were used. Two MPR software packages, ToothPix and DentaScan program, were used for reformatted panoramic images. The block and the gantry were equally inclined at 0°, 15°, and 30°. Results: With ToothPix program, a resin block model with empty holes and a dry mandible showed inclined images in the reformatted panoramic image. Increasing the gantry angle, the depth and inclination of the holes were increased in the reformatted central panoramic images. However, a resin block model with gutta perch a in its holes and a dry mandible with a wire in its mandibular canal didn't show image distortion. With DentaScan program, image distortion was not seen in any situation. Conclusion: ToothPix program may distort the reformatted image when the gantry angle is not at zero degrees. However, with DentaScan program, the patient may be positioned comfortably and the gantry can be adjusted to the patient positioning.

  • PDF

당뇨 유도 백서 경골에 매식한 티타늄 임플란트 주위에 지방조직 유래 줄기세포 적용 시 골치유에 미치는 영향 (Effect of adipose-derived stem cells on bone healing on titanium implant in tibia of diabetes mellitus induced rats)

  • 김민구;정인교;신상훈;김철훈;김복주;김정한;황영섭;정유진;김진우;김욱규
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제36권5호
    • /
    • pp.392-401
    • /
    • 2010
  • Introduction: Diabetes mellitus, as a major health problem for the elderly has been shown to alter the properties of the bone and impair bone healing around a titanium implant in both humans and animals. The aim of this study was to examine the effect of adipose-derived stem cells on the healing process around a titanium implant in streptozotocin-induced diabetic rats. Materials and Methods: Thirteen rats were divided into two groups: adipose-derived stem cells injected group and a control group. A titanium screw implant (diameter: 2.0 mm, length: 3.5 mm) was placed into both tibia of 13 rats: 13 right tibia as the control group and 13 left tibia as the experimental group. The rats were sacrificed at different intervals (1, 2, and 4 weeks) after implantation for histopathology observations and immunohistochemistric analysis. Results: The histopathological findings revealed earlier new formed bone in the experimental group than the control group. In particular, at 1 week after implantation, the experimental group showed more newly formed bone and collagen around the implant than the control group. In immunohistochemistric analysis, osteoprotegerin (OPG) expression in the experimental group increased early compared to that of the control group until 2 weeks after implantation. However, after 2 weeks, OPG expression in the experimental group was similar to OPG expression in the control group. The receptor activator of nuclear factor ${\kappa}B$ ligand (RANKL) expression in the experimental group increased early compared to that of the control group, and then decreased at 2 weeks. After 2 weeks, the level of RANKL expression was similar in both groups. Conclusion: These results suggest that adipose-derived stem cells in implantation can promote bone healing around titanium, particularly in diabetes mellitus induced animals.

치아회분(齒牙灰粉)과 도재(陶材) 복합(複合) 매식체(埋植體)에 관(關)한 광학현미경(光學顯微鏡) 급(及) 주사전자현미경적(走査電子顯微鏡的) 연구(硏究) (A Light and Scanning Electron Microscopic Study on the Implant of Tooth Ash-Porcelain Mixture)

  • 조영학
    • 대한치과보철학회지
    • /
    • 제22권1호
    • /
    • pp.33-50
    • /
    • 1984
  • The purpose of this study was to investigate whether the ashed tooth powder is utilized as an alternative material of the implant to recovery the bony defect. For this purpose its biocompatibility was evaluated comparing to the synthetic calcium phosphate compounds, such as Syntograft and Calcitite, as well as the vacuum firing porcelain (Ceramco Inc.) which is anticipated to use as a matrix to aid sintering. Bony defects to exposure the bone marrow, $3{\times}5$ mm in size, were created in the right and left tibias of fifteen rabbits, and then the ashed tooth powder at $950^{\circ}C$, the porcelain powder, Syhtograft and Calcitite were inserted in the defects of twelve rabbits of the experimental group and the blood clot only was filled in the defects of three rabbits of the control group. The experimental and control rabbits were sacrificed at 1st, 2nd 3rd week after implantation and the histologic examination was performed. The ashed tooth powder in order to make the needed form of the implant was molded using the cylindrical mold 1 cm high, 1 cm in diameter under the pressure of $1000kg/cm^2$ and the ashed tooth powder was sintered at $1100^{\circ}C$ for 1 hour and the mixture of the porcelain powder and the ashed tooth powder at the weight ratio of 7:3, 6:4, 5:5, 4:6 were molded in the same manner and were sintered at $925^{\circ}C$. From this sintered material, square shaped implants were prepared in the dimension of $2{\times}4{\times}6mm$. The prepared implants were surgically placed in the subperiosteum of lateral surfaces of the right and left mandibular bodies. The dogs were sacrificed at 4 weeks, and then the specimens were examined using the light and scanning electron microscopes. The results of this study were obtained as follows: 1. Any inflammatory response was not noted after implanting of the ashed tooth powder, Syntograft, Calcitite and the porcelain powder during the whole experimental period after implantation. 2. Induction of the new bone formation was significantly shown in the ashed tooth powder, Syntograft and Calcitite. 3. The more the porcelain powder was contained in the implants, the more the porosity was and the bigger the pore size was under the scanning electron microscope. And there was ingrowing of the fibrous connective and the osteoid tissue. 4. The osteoid tissues were found to be directly fused to the implant of the ashed tooth powder, and the mixture implant of the porcelain powder and the ashed tooth powder at the weight ratio of 4:6 under the light and scanning electron microscopes.

  • PDF

치아회분(齒牙灰粉)과 도재복합(陶材複合) 매식체(埋植體)의 물리적(物理的) 성질(性質) 및 세포배양(細胞培養)에 의(依)한 조직친화성(組織親和性)에 관(關)한 연구(硏究) (A Study on the Physical Properties and Cytotoxicity of Tooth Ash and Dental Procelain)

  • 호기영
    • 대한치과보철학회지
    • /
    • 제22권1호
    • /
    • pp.51-68
    • /
    • 1984
  • The purpose of this study is primarily to test the use value of tooth ash as an alternative material of the synthetic hydroxyapatite. For this purpose the author performed the experimental study to investigate the phsyical properties of sintered tooth ash and its histocompatibility in vitro. The tooth ash was made by incinerating procedure at $650^{\circ}C,\;750^{\circ}C,\;850^{\circ}C,\;950^{\circ}C\;and\;1050^{\circ}C$ respectively. The composition of tooth ash was analyzed and X-ray diffraction was done. The experimental specimens were molded to the cylinderical form 1 cm high, 1 cm in diameter under the pressure of $1000kg/cm^2$, which were divided into two groups; the one is sintered tooth ash at $1100^{\circ}C$ and the other is fired mixture of tooth ash and dental porcelain mixed to the weight ratio of 4:6, 5:5, 6:4 and 7:3. The physical propoerties of the sintered specimens were examined and their microstructure was observed under the Scanning Electron Microscope. The results obtained were as followings: 1. The difference of the tooth ash composition depending on incinerating temperature was of no significance, but the $CO_2$ disappeared from $950^{\circ}C$. 2. X-ray diffraction showed the tooth ash was mainly composed of hydroxyapatite and a small amount of - white lockite. But phase transformation was not disclosed. 3. The microstructure of the sintered specimens of the ashed tooth powder was of no difference in the structure and grain size accompanying the ashed temperature, but sintering ability seemed to be the best in the specimen incinerated at $950^{\circ}C$. 4. There was good wettability in the mixed sintered specimens of the ashed tooth powder and the porcelain powder. 5. The compressive strength of the sintered specimens of the tooth ash incinerated at $950^{\circ}C$ was the highest with $589.75kg/cm^2$ and the porosity and the absorption were the lowest as well. 6. The mixed sintered specimens of the tooth ash and porcelain powder was good in the physical properties in the case of mixed weight ratio of 6:4. 7. The animal fibroblast cultures with porcelain showed increase in the cell number, whereas the tooth ash showed a small degree of growth inhibition. But the difference of cell multiplication efficiency between control cultures and test cultures with tooth ash was not observed.

  • PDF