• Title/Summary/Keyword: 막 오염물질

Search Result 235, Processing Time 0.021 seconds

Effect of Membrane Materials on Membrane Fouling and Membrane Washing (막의 재질에 따른 막오염 특성 및 물리·화학적 세척의 영향)

  • Shim, Hyun-Sool;Jung, Chul-Woo;Son, Hee-Jong;Sohn, In-Shik
    • Korean Chemical Engineering Research
    • /
    • v.45 no.5
    • /
    • pp.500-505
    • /
    • 2007
  • The objectives of this research were to (1) identify the membrane fouling potential due to different fractions of NOM (2) correlate the physicochemical properties of NOM and membranes with the adsorption of humic substances on membrane (4) find out the effect of membrane physical and chemical washing according to membrane material. The static adsorption test and adsorption test showed that hydrophobic organics adsorbed much more quickly than hydrophilic organics. In case of the effect of membrane properties on the adsorption of organic fractions, the adsorption rate ratio(a) of hydrophobic membrane (0.016, 0.077) was greater than that of hydrophilic membrane (0.010, 0.033) regardless of the kind of organic fractions. This suggests that the UF membrane fouling were occurred mainly by internal pore size decreasing due to adsorption of organic into pore surface for hydrophobic membrane, and by sieving of organics and forming a gel layer on the membrane surface for hydrophilic membrane. In conclusion, the decrease in the pore volume, which was caused by the organic adsorption into the internal pore, was greater with the hydrophobic membrane than with the hydrophilic membrane. In case of the effect of membrane properties on permeate flux, the rate of flux decline for the hydrophobic membrane was significantly greater than that for the hydrophilic membrane.

Factors Affecting Membrane Fouling in Membrane Filtration of Activated Sludge (막결합형 활성슬러지 시스템에서의 막오염 유발 인자)

  • Chang, In-Soung;Lee, Chung-Hak
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.2
    • /
    • pp.323-329
    • /
    • 2000
  • The coupling of an activated sludge reactor with a membrane unit, i.e., Membrane Coupled Activated Sludge (MCAS) system offers several advantages over conventional process. But the major hurdle in the extensive use of this process is the continuous reduction of permeation flux caused by membrane fouling. The aim of this study is to investigate membrane fouling characteristics in the MCAS process. During crossflow ultrafiltration(CFUF) of activated sludge, floc size decreased abruptly at the beginning of operation and thereafter decreased continuously and gradually. The floc size changed from 100~200 to $6{\sim}8{\mu}m$ depending on recirculation velocity. This floc breakage played a key role in rapid increase of $R_c$(cake layer resistance), which led to flux decline. The floc breakage stimulated biomass to release EPS(Extracellular Polymeric Substance) which has been known to be one of the major membrane foul-ants. The amounts of EPS before and after CFUF were 266 and 405(VS mg/MLSS g), respectively. The rise up of EPS concentration was another factor affecting flux decline in MCAS system.

  • PDF

UF Separation of the Waste Water Containing Silicon Fine Particle (Si 미립자 함유 폐수의 UF 투과 특성)

  • 이석기;김우정;전재홍;곽순철;남석태;최호상
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1997.10a
    • /
    • pp.129-130
    • /
    • 1997
  • 1. 서론 : 반도체 제조공정중 wafer가공 공정에 사용되는 많은 양의 RO 초순수는 미세한 규소입자를 비롯하여 비교적 낮은 농도의 불순물을 포함하고 있으나, 현재 1차세정후 공정폐수로 전량 희석되어 폐기되고 있다. 반도체 제조공정에서 발생되는 이러한 세정폐수를 적절한 전처리와 분리막 처리를 통하여 유가물질인 Si 입자를 회수하고, 처리수를 재이용함으로써 환경오염의 감소 및 공업용수의 증대를 도모할 수 있다. 본 연구에서는 고분자 분리막을 이용하여 반도체 제조공정중 발생한 세정중의 유가물질인 Si를 회수하고, 용수를 재이용하기 위하여 한외여과용 평막을 제조하여 Si 함유 폐수에 대한 막성능을 평가하였으며, 또한 상용 tubular 및 hallow fiber막의 성능과도 비교하였다.

  • PDF

Treatment of Textile Wastewater by Membrane-Bioreactor Process (막-생물반응조 공정을 이용한 염색폐수의 처리)

  • 강민수;김성수;황규대;강종림
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1996.10a
    • /
    • pp.60-61
    • /
    • 1996
  • 염색폐수를 처리하기 위하여, 일반적으로 물리.화학적 공정과 호기성 생물학적 공정을 조합한 방법들을 사용하고 있다. 하지만 호기성 생물학적 공정은 난분해성 물질의 제거능력이 낮고, 염색폐수의 주된 오염원인 염료분자가 호기성 미생물에 대한 에너지원으로 적합하지 않아 분해되기 어려우며, 물리.화학적 공정을 이용한 처리방법으로도 높은 처리효율을 얻을 수가 없다. 이러한 문제점을 극복하기 위하여 염색폐수 처리에 혐기-호기공정을 이용하며, 혐기성 공정에서 생물학적으로 분해되기 어려운 고분자 물질들을 가수분해하여 생물학적으로 분해가능한 저분자물질로 전환시키고, 호기성 공정에서 저분자 물질을 효과적으로 처라할 수 있기때문에 기존의 염색폐수 처리공정에 비하여 훨씬 높은 처리효율을 얻을 수 있다. 특히, 혐기성 미생물은 호기성 미생물에 비하여 난분해성 물질에 대한 분해력이 높고, 생물독성 물질에 대한 내성이 강하기 때문에 수중생물에 유해한 염료를 함유한 염색폐수의 색도제거에 효과적인 것으로 기대된다. 또한, 막분리 공정은 유기물 및 미생물이 막표면에 축적, 증식함으로써 막세공에 막힘현상을 초래하여 역세척 등의 물리적인 방법이나 화학약품을 이용한 화학적 세척 방법으로도 투과플럭스의 회복이 불가능한 상태를 유발함으로 막의 수명을 단축시키는 원인이 된다. 따라서, 혐기-호기공정과 조합하면 색도성분 제거 및 막 오염의 원인이 되는 유기물 및 용존성 고형물을 제거하고, 막 오염의 억제를 통한 후 수염의 연장은 물론, 처리수의 수질향상에 활용될 수 있을 것으로 사료된다.1로 강구와 함께 공구강 vial에 장입 후, Spex mixer/mill을 이용하여 기계적 합금화 하였다. 기계적 합금화 공정으로 제조한 분말에 대한 X-선 회절분석과 시차 열분석으로 합금화 정도를 분석하였다. (Bi1-xSbx)2Te3 및 Bi2(Te1-ySey)3 합금분말을 10-5 torr의 진공중에서 300℃∼550℃의 온도로 30분간 가압소결하였다. 가압소결체의 파단면에서의 미세구조를 주사전자현미경으로 관찰하였으며, 상온에서 가압소결체의 열전특성을 측정하였다. (Bi1-xSbx)2Te3의 기계적 합금화에 요구되는 공정시간은 Sb2Te3 함량에 따라 증가하여 x=0.5 조성에서는 4 시간 45분, x=0.75 조성에서는 5 시간, x=1 조성에서는 6 시간 45분의 vibro 밀링이 요구되었다. n형 Bi2(Te1-ySey)3 합금분말의 제조에 요구되는 밀링시간 역시 Bi2Se3 함량 증가에 따라 증가하였으며 Bi2(Te0.95Se0.05)3 합금분말의 제조에는 2시간, Bi2(Te0.9Se0.1)3 및 Bi2(Te0.85Se0.15)3 합금분말의 형성에는 3시간의 bivro 밀링이 요구되었다. 기계적 합금화로 제조한 p형 (Bi0.2Sb0.8)2Te3 및 n형 Bi2(Te0.9Se0.1)3 가압 소결체는 각기 2.9x10-3/K 및 2.1x10-3/K 의 우수한 성능지수를 나타내었다.ering)가 필수적이다. 그러나 침전법에서 얻게 되는 분말은 매우 미세하여 colloid를 형성하게 되며, 이러한 colloid 상태의 미세한 침전입자가 filte

  • PDF

Physicochemical Effect on Permeate Flux in a Hybrid Ozone-Ceramic Ultrafiltration Membrane Treating Natural Organic Matter (자연유기물을 처리하는 혼합 오존-세라믹 한외여과 시스템에서 물리화학적 특성이 투과플럭스에 미치는 영향)

  • Kim, Jeong-Hwan
    • Membrane Journal
    • /
    • v.18 no.4
    • /
    • pp.354-361
    • /
    • 2008
  • Effects of operational conditions and solution chemistry on permeate flux in a hybrid ozone-ceramic ultra-filtration (UF) membrane system treating natural organic matter (NOM) were investigated. Results showed that the extent of permeate flux decline was higher at higher cross-flow velocity and ozone dosage, but it was higher at lower transmembrane pressure (TMP). The mechanism of fouling mitigation was found to be more dependent upon reaction between ozone and natural organic matter at/near catalytic membrane surface than scouring effect due to ozone gas bubbles. Addition of calcium into model NOM solution at high pH led to significant decline in permeate flux while the calcium effect on permeate flux decline was less pronounced at lower pH. After permeate flux decline during the early stage of filtration, the flux started recovering and approached fully to the initial value of it due to degradation of NOM by catalytic ozonation at ceramic membrane surface in the hybrid ozone-ceramic membrane system.

Improvement of surface defects by pre-treatment process capability upgrade in plating process (도금공정 전처리 성능개선을 통한 표면결함 개선)

  • O, Min-Yeong
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2015.11a
    • /
    • pp.193-193
    • /
    • 2015
  • 도금공정에 있어서 전처리는 제품품질을 확보하는데 중요한 단계이다. 전처리 공정의 주요인자중 처리액의 온도, 처리시간, 교반력, 오염도를 개선함으로써 제품의 산화막 및 오염물질을 효과적으로 제거할 수 있었다.

  • PDF

Effect of Operating Conditions on the Fouling of UF Membrane in Treatment of Dissolved Organic Matter (UF를 이용한 용존성 유기물질 제거시 운전조건이 파울링에 미치는 영향)

  • Kwon, Eun-Mi;Yu, Myong-Jin
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.7
    • /
    • pp.1183-1191
    • /
    • 2000
  • Operating conditions for reduction of membrane fouling in treatment of dissolved organic matter by UF membrane process were investigated by pilot-scale plant using various operating conditions. As inlet pressure increased, increament of transmembrane pressure and flux decline were faster. The reason was due to the increase in adsorption of dissolved organic matter and the development of cake layer compression on the membrane surface. When efficient pressure (the difference of pressure between backwash and transmembrane pressures) was high, small amount of pollutant was retained on the membrane surface. When backwash was frequently conducted, low concentration of pollutant was maintained in recycling water. Therefore, backwash could be efficiently conducted with high efficient pressure and high frequency. Fouling rate was correlated with backwash and inlet pressures, recovery rate and cumulative permeated volume. Among the operating parameters backwash pressure was most closely related to fouling rate and inlet pressure was next to backwash pressure. It seems that the fouling was strongly related to pressure which leads to the cake layer compression and adsorption of dissolved organic matter.

  • PDF

Effect of operating condition of electro-coagulation on the membrane filtration resistances of activated sludge (전기응집 조건이 활성슬러지 막 여과 저항에 미치는 영향)

  • Hong, Sung-Jun;Chang, In-Soung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.3
    • /
    • pp.2314-2320
    • /
    • 2015
  • MBR (Membrane Bio-Reactor) process is known to consume enormous energy to control membrane fouling. To solve this problem, electro-coagulation technique has been applied to MBR. A series of electro-coagulation was applied to activated sludge suspension under different current density condition. After the electro-coagulations, membrane filtration of the activated sludge suspensions was conducted to investigate the effect of electro-coagulation on the fouling. As current density increased 10 to 40A/m2, the total fouling resistance (Rc+Rf) decreased from 18 to 79%, showing that the electro-coagulation improved the membrane filtration efficiency. Both the organic concentration in bulk and the particles size distribution were not nearly changed before and after the electro-coagulation. The enhanced filtration efficiency might be due to the aluminum hydroxide generated from chemical precipitation, which can be acted as a dynamic membrane preventing a deposition of foulants on membrane surfaces.

부식질 존재하에서 PAC-UF 시스템을 이용한 미량유기물의 제거

  • 이승진;이정학
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1996.10a
    • /
    • pp.64-66
    • /
    • 1996
  • 원수 중의 오염물의 양과 종류가 급격히 증가함에 따라 기존의 정수방법은 점차 그 한계를 노출하고 있다. 이러한 문제점의 대안으로 최근 막분리기술을 도입한 고도정수처리공정이 주목되고 있다. 역삼투(reverse osmosis)와 나노여과(nanofiltration)등의 분리막을 이용한 정수처리 공정에 대한 연구가 활발히 진행되어 왔으나, 경제성이 보다 큰 한외여과(ultrafiltration, UF)와 부날활성탄(powdered activated carbon, PAC)의 결합 시스템의 도입이 연구되고 있다. 따라서 본 연구에서는 PAC-UF 시스템의 유입수에 배경물질(background organic matters, BOM)을 포함한 이성분계에서 미량유기물의 경쟁적 흡착 거동을 고찰하였다.

  • PDF