• Title/Summary/Keyword: 막분리 활성슬러지공법

Search Result 5, Processing Time 0.02 seconds

Field Application of Ultra Biological System (한외여과막을 이용한 활성슬러지법의 현장시험 연구)

  • 정윤철;박흥석;김문성
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1991.10a
    • /
    • pp.41-42
    • /
    • 1991
  • 본 연구는 활성슬러지공법의 침전조를 막으로 대체하여 고액분리를 효과적으로 수행하도록 하는 막분리 활성슬러지 공법에 관한 것이다. 이와같은 방법은 공정자체가 간략화되는 동시에 종래법에서 슬러지 팽화(bulking)등에 의해 침전조에서 SS carry-over, 슬러지 침강성 향상을 위한 고부하처리의 곤란성, 침전조 처리수에의 SS 유출등 고액 분리의 문제점을 해소하므로, 여과, 응집침전, 혹은 활성탄흡착등의 고도처리설비없이 양질이 처리수를 얻을 수 있다고 보고 되고 있다.

  • PDF

Advanced Treatment of Sewage and Wastewater Using an Integrated Membrane Separation by Porous Electrode-typed Electrolysis (분리막/다공 전극형 전기분해 조합공정을 이용한 하.폐수의 고도처리)

  • Choi, Yong-Jin;Lee, Kwang-Hyun
    • Membrane Journal
    • /
    • v.22 no.2
    • /
    • pp.95-103
    • /
    • 2012
  • To treat nitrate and non-biodegradable organics effectively in sewage, industrial wastewater and livestock wastewater, the activated sludge process integrated by a membrane separation and a porous electrode- electrolysis was proposed and its efficiency was investigated. The proposed system was consisted of 3 processes; activated sludge, membrane filtration and electrolysis. In the study, the membrane filtration played a role in reducing the load of the electrolysis to operate the proposed process stably. The electrolysis consisted of a porous electrode to increase the efficiency due to the extension of the specific surface area. Additionally, redox reaction in the electrolysis was induced by decomposing influent water as current was applied. As a result, hydrogen free radicals and oxygen radicals as intermediates were produced and they acted as oxidants to play a role in decomposing non-degradable organics. It was environmentally-friendly process because intermediates produced by porous electrode were used to treat waste matters without supplying external reagent. Experimental data showed that the proposed process was more excellent than activated sludge process. SS removal efficiencies of the proposed process, membrane filtration and activated sludge process were about 100%, about 100% and about 90%, respectively. COD removal efficiencies of the proposed system, membrane filtration and activated sludge process were about 92%, about 84% and about 78%, respectively. T-N removal efficiencies of the proposed system, membrane filtration and activated sludge process were about 88%, about 67%, and about 58%, respectively. The SS data showed that SS was efficiently removed in the single of the membrane filtration. The COD/T-N data showed that COD/T-N of membrane hybrid process was treated by removing a little soluble organics and SS, and that COD/T-N of electrolysis hybrid process was treated by oxidize organics with high removal rate.

Evaluation of Tubular Type Non-woven Fabric Filter for Solid-liquid Separation in Activated Sludge Reactor (활성슬러지조내 부직포 여재 관형필터의 고액분리 특성 평가)

  • Seo, Gyu-Tae;Lee, Teak-Soon;Park, Young-Mi
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.30 no.2
    • /
    • pp.234-238
    • /
    • 2008
  • Coarse pore filter could be an alternative of membrane for solid-liquid separation in an activated sludge reactor because of inexpensive cost of the filter material and high flux at low filtration pressure. However such filter module has much less specific filtration area compared to the membrane. Therefore a certain effort is required to increase the specific filtration area in the module design of such coarse pore filter for solid-liquid separation in an activated sludge reactor. In this study, tubular type coarse pore filter was designed at various diameter and configuration. The filtration performance was investigated to separate solid in the activated sludge reactor for domestic wastewater treatment. Tubular type coarse pore filter module could be successfully applicable to solid separation in the activated sludge reactor. The design parameters were the tube diameter of 10mm and vertical installation. Smaller diameter of the tube caused faster increase of the filtration pressure because of the hydraulic head loss in the tube channel.

A Study on the Sludge-reduced Sewage Treatment Process Combined with Sludge Solubilization Technique Using Alkalophiles (호알칼리미생물을 이용한 슬러지감량형 하수처리공정 연구)

  • Shin, Kyung-Sook;Kim, Yoon-Seok;Han, Dae-Hoon;Han, Woon-Woo;Rhee, Young-Ha;Hur, Hyung-Woo
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.21 no.6
    • /
    • pp.737-744
    • /
    • 2007
  • Recently, one of the most interesting topic in the field of wastewater treatment is the disposal of excess sludge. The new concept of excess sludge reduction with recirculation of solubilized sludge via effective microorganisms for cell disruption within the wastewater treatment process has been developed in this study. The alkalophiles for degradation of sludge cell wall were isolated as Exiguobacterium sp., which could be more effectively solubilized sludge in the anaerobic condition. The SCOD of solubilized excess sludge by Exiguobacterium sp. was up to about 2,000mg/L and average TN and TP concentration of solubilized component were 117mg/L and 58mg/L, respectively and C/N ratio was more than 17. To investigate the effects of solubilized sludge by alkalophiles on excess sludge reduction and nutrient removal efficiency, the pilot plant of $DF^{(S)}-MBR$ process, combined with membrane bioreactor and sludge solubilization tank, was operated. In the control run(without sludge solubilization), the daily sludge production was about 4.54 kgMLVSS/day. However, in the $DF^{(S)}-MBR$(with sludge solubilization), the daily sludge production was decreased to 1.39kgMLVSS/day. The effluent quality satisfied the effluent regulation in both cases. Furthermore, the $DF^{(S)}-MBR$ showed relatively better TN removal efficiency in spite of high influent loading. So we concluded that the solubilized excess sludge by alkalophiles was effectively degraded in the MBR process as the carbon source and 70% of sludge reduction efficiency can be achieved.

Method of Reducing Separation Membrane Fouling Using Microbubbles (마이크로버블을 이용한 분리막 파울링 저감방법)

  • Kyung-Hwan Ku;Younghee Kim
    • Clean Technology
    • /
    • v.29 no.1
    • /
    • pp.31-38
    • /
    • 2023
  • Due to water shortages caused by water pollution and climate change, total organic carbon (TOC) standards have been implemented for wastewater discharged from public sewage treatment facilities. Furthermore, there is a growing interest and body of research pertaining to the reuse of sewage treatment water as a secure alternative water resource. The membrane bio-reactor (MBR) method is commonly used for advanced wastewater treatment because it can remove organic and inorganic ions and it does not require or emit any chemicals. However, the MBR process uses a separation membrane (MF), which requires frequent film cleaning due to fouling caused by a high concentration of mixed liquor suspended solid (MLSS). In this study, process improvement and microbubble cleaning efficiency were evaluated to improve the differential pressure, water flow, and MF fouling, which are the biggest disadvantages of operating the MF. The existing MBR method was improved by installing a precipitation tank between the air tank and the MBR tank in which raw water was introduced. Microbubbles were injected into a separation membrane tank into which the supernatant water from the precipitation tank was introduced. The microbubble generator was operated with a 15 day on, 15 day off cycle for 5 months to collect discharged water samples (4L) and measure TOC. As the supernatant water from the precipitation tank flowed into the separation membrane tank, about 95% of the supernatant water MLSS was removed so the MF fouling from biological contamination was prevented. Due to the application of microbubbles to supernatant water from the precipitation tank, the differential pressure of the separation membrane tank decreased by 1.6 to 2.3 times and the water flow increased by 1.4 times. Applying microbubbles increased the TOC removal rate by more than 58%. This study showed that separately operating the air tank and the separation membrane tank can reduce fouling, and suggested that applying additional microbubbles could improve the differential pressure, water flow, and fouling to provide a more efficient advanced treatment method.