Analysis of Performance of Multi-functioned frictional force measuring instrument using adaptive smoothing (적응화 평활화법을 이용한 다기능 마찰력 측정기의 성능 분석)

  • Kim, Tae-Soo;Kim, Gwang-Su
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.12 no.2
    • /
    • pp.113-119
    • /
    • 2019
  • We have developed the multi-functioned friction measuring instrument for the previous research. In here, we improved the performance of friction measuring instrument by applying the adaptive smoothing method and analyzed the friction of plate and monitoring function of friction surface through scratch tests. We substituted lubricant steel plate to lubricant oil used for reducing the friction when fabricating steel plate because lubricant oil was regarded as one of the major causes for the environmental pollution. In particular, the functions of various plate such as galvannealed steel sheets were analyzed because friction coefficient could be changed depending on the type of organic/inorganic plate or state of coating layer. Therefore, we demonstrated that adaptive smoothing method could enhance the accuracy of measuring instrument which eliminate the noise. As a result of using the method, it showed the reduction rate 0.0417% for the friction coefficient 0.16.

A Study on Characteristics of Drag Reduction Additive under High Temperature Range (고온영역에서 계면활성제의 마찰저감 성능 특성에 관한 연구)

  • Cho, Sung-Hwan;Ryu, Jae-Sung;Jung, Sang-Hoon
    • Journal of Energy Engineering
    • /
    • v.19 no.2
    • /
    • pp.116-120
    • /
    • 2010
  • Overall total length of hydraulic pipe to transport the hot water in the domestic district heating network is above 3,000 Km approximately. This long pipe network requires a lots of the transport pumping power by surface friction of fluid. In this study, the drag reduction(DR) of Amin Oxide $C_{18}$ as non-ionic surfactant according to the fluid velocity, temperature and surfactant concentration under the condition of above $80^{\circ}C$ fluid temperature were investigated experimentally. Results showed that new amin oxide $C_{18}$ surfactant had DR of maximum 30% in fluid temperature of $80^{\circ}C$ and had 15% DR in fluid temperature over $100^{\circ}$ under short time test condition. And amine oxide had 155 hours duration time to keep the DR characteristic in the fluid temperature of $80^{\circ}$ and 1000 ppm concentration. But duration time of DR was decreased when fluid temperature increased.

A Study on the Load Bearing Characteristics Depending on Pile Construction Methods and Pile Load Test Methods Based on Case Analyses (사례분석에 기초한 말뚝시공법 및 재하시험방법에 따른 하중지지특성에 관한 연구)

  • Hong, Seok-Woo;Choi, Yong-Kyu
    • Journal of the Korean Geotechnical Society
    • /
    • v.28 no.4
    • /
    • pp.5-21
    • /
    • 2012
  • In our country, in the case of traditional design of pile foundations, only a design depending on end bearing has been performed. However, through the load transfer measurement data that have been carried out for in-situ piles, it was known that skin frictional force was mobilized greatly. In this study, through the analysis of the load transfer test cases of driven steel pipe piles and large-diameter drilled shafts, load bearing aspects of pile foundation depending on pile construction methods and pile load test methods were established. The average sharing ratios of skin frictional force were independent of pile types, pile load test methods, relative pile lengths, pile diameters and soil types. Because the average sharing ratios were over 50%, the case pile foundations mostly behaved as a friction pile and the extremely partial case pile foundation behaved as a combined load bearing pile.

단일 타겟을 이용한 반응성 마그네트론 스퍼터링 공정에 의한 나노 복합구조의 MoN-Cu 코팅층 형성 기술 개발

  • Jeong, Deok-Hyeong;Lee, Han-Chan;Sin, Seung-Yong;Mun, Gyeong-Il
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.02a
    • /
    • pp.237-237
    • /
    • 2010
  • 에너지소비와 엔진 부품의 마모문제를 해결하기 위해, soft-phase를 doping한 hard상의 coating에 대한 실험이 최근 중요한 연구 테마로서 진행 중이다. 특히 MoN-Cu coating은 미국 Argon 연구소의 Erdemer박사 등에 의해, 고온 및 상온 윤활성이 우수한 코팅층으로 보고된 이후 많은 연구가 진행되고 있다. 그러나 기존 연구는 Mo와 Cu의 원소타겟을 이용한 연구가 주력이 되었다. 높은 경도와 저온 고온에서의 낮은 나노 혼합물 코팅 종류는 일반적으로 Mo와 Cu와 같은 원소 합금을 이용한 다수 타겟을 이용한 공정에 의해 진행되어왔다. 이러한 복수의 타겟에 의해 증착 동안에는, 정확한 조성, 큰 크기의 시편들의 균일 증착을 조절하기가 쉽지 않다. 또한, 코팅층에 3번째 성분을 추가하기가 어렵다는 문제점이 있다. 본 연구에서는, 최상의 마찰계수와 표면경도를 보이는 MoN-Cu층을 형성시키기 위하여 합금으로 단일 타겟을 제조하였다. 이를 위한 최적 조성을 결정하기 위하여 Mo, Cu 단일 타겟을 이용한 Unbalanced Magnetron sputtering 법으로 다양한 Cu 함량의 MoN+Cu 합금을 제조하였으며, 이에 대한 경도 및 마찰계수 측정을 통해 최적의 Cu 함량을 결정하였다. 이러한 최적 조성의 Cu 타겟제조를 기계적 합금화와 Spark plasma sintering 기술을 이용하여 제작하였으며, 복수의 합금 타겟과 단일 합금 타겟으로 제조된 코팅층의 물성 비교를 통해 합금 타겟의 우수성 여부를 확인하고자 하였다. 증착된 두 조건의 물성을 비교 단일 타겟은 두가지 타겟으로 증착한 것보다 비슷한 조성에서 경도가 높았으며 경도가 비슷한 조성에서는 마찰계수가 낮았다. 또 입자는 10 at.% Cu 조성에 대해 단일타겟이 50nm 결정립을 갖는 반해 단일타겟은 측정이 불가능할 정도의 미세한 결정립을 가졌다. Erdemir의 연구 결과에 의하면, Cu 함량이 증가함에 따라 columnar 형태의 코팅층구조가 나노 구조로 변한다고 하였는데, 본 연구에서 복수의 원소 타겟에서는 확인이 안되었으며, 단일 합금 타겟에서 완벽한 featurless 형태의 코팅층 구조와 우수한 조도의 박막층을 얻을 수 있었다. 이렇게 제조된 다양한 코팅층에 대한 마찰계수 측정이 진행중이다.

  • PDF

The Effect of Surface Engineering on Nanoscale Adhesion and Friction of Nano and Energy Materials

  • Park, Jeong-Yeong
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2013.05a
    • /
    • pp.35-36
    • /
    • 2013
  • 본 발표는 atomic force microscopy (원자력현미경) 기법을 이용하여 그래핀을 포함한 다양한 나노물질의 물리적, 화학적, 역학적, 또한 전기적 특성의 상호영향 (correlation)의 이해를 목표로 한다. 원자력 현미경은 표면과 검침사이의 물리적 힘을 측정하고 이를 피드백시킴으로써 표면의 형상을 얻는 원리이며 표면의 역학적 (마찰력, 점착력), 전기수송적 특성을 동시에 측정할 수 있는 이점이 있다. 또한 원자력 현미경은 표면의 구조적인 특성과 표면에너지에 대한 정보를 나노미터 스케일에서 줄 수 있다. 나노선, 나노입자, 또한 연료전지의 모델 시스템에서 원자력현미경을 이용한 표면의 나노역학적 특성 및 점착력의 측정이 다루어질 것이며 표면공학을 통한 표면처리에 따른 마찰력과 점착력의 제어를 논의할 것이다.

  • PDF

Evaluation on Fatigue Behavior of EP(Engineering Plastic) Friction Pendulum Bearing System (EP가 적용된 마찰 진자형 지진격리받침의 피로거동분석)

  • Choi, Jung-Youl;Park, Hee-Soo;Chung, Jee-Seung
    • The Journal of the Convergence on Culture Technology
    • /
    • v.6 no.4
    • /
    • pp.703-708
    • /
    • 2020
  • As the risk of earthquakes increases recently, earthquake-resistant designs were getting interest. For this reason, this study applies that Friction pendulum-type seismic isolator is a device that attenuates seismic energy by friction and pendulum motion. The friction pendulum-type seismic isolator of this study is very easy to transport, install and maintain with light weight of metal by applying the slider using high strength engineering plastic. In addition, there is an advantage that the corrosion resistance is very excellent compared to the existing metal parts. However, there is concern about long-term durability by replacing metal materials. In this study, the frictional pendulum-type seismic isolator with EP was applied to compressive-shear test, repeated fatigue test, and ultimate load test after fatigue test, and analyzed the deformation and shear or properties after the test. As the results, the adequacy of long term fatigue durability was experimentally proven.

Experimental Study on the End Bearing Capacity of the Pile in a Group Pile (무리말뚝을 구성하는 개별말뚝의 선단지지력에 대한 실험연구)

  • Na, Yong Soo;Lee, Sang Duk
    • Journal of the Korean Geotechnical Society
    • /
    • v.35 no.6
    • /
    • pp.27-38
    • /
    • 2019
  • Bearing capacity of a pile in homogeneous soil is the sum of end bearing and skin resistance, and the skin resistance is more prominent in sandy soil. Bearing capacity of a pile in pile groups especially in sandy ground should be designed under the consideration of the influence by the adjacent piles. In this study, the end bearing capacity of a pile in pile groups was experimentally investigated. For this purpose, piles were installed in sandy ground in a circular test box, and end bearing - settlement behavior of the pile was measured while the pile was loaded. As the results, end bearing - settlement relation curves of the piles showed a distinct limit value. Limit value of the end bearing was little affected by skin friction and pile diameter, and it became a constant value as pile penetrates deeper. End bearing was not affected by the adjacent piles in a group of piles, when their clearance was larger than the pile diameter.

A Comparison of Roughness Measurement and Load Transfer Test for the Calculation of Unit Skin Friction of Pile Foundation in Soft Rocks (기초 연암부 벽면거칠기 시험과 하중전이 시험 결과의 비교 및 단위주면마찰력의 산정에 대한 연구)

  • Hong, Seok-Woo;Hwang, Geun-Bae
    • Journal of the Korean Geotechnical Society
    • /
    • v.39 no.6
    • /
    • pp.21-30
    • /
    • 2023
  • One of the methods for calculating unit skin friction of soft-rock-socket parts for cast-in-place piles involves the roughness measurement of the parts. The measurements are conducted during the excavation stage. A roughness measuring device is installed in the excavation hole and the unit skin friction is calculated from the measured surface roughness of the rock socket. Herein, the results of roughness measurement of rock-socket parts in cast-in-place piles and that of load transfer tests are analyzed and compared. The unit skin friction from the roughness measurements can be converted into unit skin friction corresponding to the displacement of a pile generated in a load transfer test. A reduction factor is given as Rf = -0.14n + 1.48.

Study on the Noise Characteristics of Bridge Deck Pavements in Seoul Inner Ring Road (서울시 내부순환도로 교면포장 형식에 따른 소음특성 연구)

  • Lee, Sang-Yum;Jin, Jung-Hoon;Mun, Sung-Ho;Moon, Hak-Ryong
    • International Journal of Highway Engineering
    • /
    • v.14 no.2
    • /
    • pp.19-28
    • /
    • 2012
  • A measuring technique for tire-pavement interaction noise that uses a proposed noble close proximity(NCPX) method, which has been proofed in terms of the reliability and consistency of interaction noise measurement through several researches, equipped with surface microphones has been adopted in order to perform bridge deck pavement noise evaluations on four different pavement surfaces. Through field testing measurement of bridge deck pavement in Seoul inner ring road, the appropriate noise-measuring procedures have been used for evaluating the noise characteristics of four different surfaces. Measuring results show that tire-pavement noise levels vary depending on the surface types and vehicle speeds. Furthermore, the different characteristics of tire-pavement interaction noise can be found before and after the new surface construction of bridge deck pavements in terms of the 1/3 octave band analysis of vehicle speed.

Analysis on Foaming Properties of the PANI added MWNT/PU Films (PANI 첨가 MWNT/PU 필름의 발포특성)

  • Ma, Hye-Young;Choi, La-Hee;Park, Mi-Ra;Kim, Seung-Jin
    • Proceedings of the Korean Society of Dyers and Finishers Conference
    • /
    • 2012.03a
    • /
    • pp.63-63
    • /
    • 2012
  • 전자제품 패키지에 요구되는 쿠션성과 정전방전 기능을 갖는 폴리우레탄 발포 필름의 제조기술을 확립하게 되면 IT산업용에 적용 가능한 필름제품이 개발되어 ESD(정전방전, Electrostatic Dissipation) 성능을 발휘하게 됨으로서 정전기 쇼크에 의한 각종 전자제품의 오작동이나 파손 방지가 가능하게 되어 포장재, 자동차 전자제품의 하우징 등으로 사용될 수 있게 된다. 전도성 고분자인 Polyaniline (PANI)은 다른 여러 고분자와 비교하여 볼 때 다른 유형의 전도성 고분자보다 합성하기가 쉽고 높은 전기전도도를 보임은 물론 열적 및 대기 안정성이 우수하며 가격이 저렴한 장점을 가지고 있다. 본연구는 CNT 나노기술을 응용한 IT산업용 적층간지용 ESD PU발포필름의 제조 가공기술 및 상품화 개발을 수행하고자 방수, 투습방수성을 가지는 유연재료인 폴리우레탄(PU)의 1액형 PU와 DMF에 PANI의 함량을 5, 10, 15, 20, 25, 30wt%로 변화시켜 제조한 PANI/DMF 분산용액과 IPA/MWNT 3wt% 분산용액의 혼용비에 변화를 주어 $120^{\circ}C$에서 2분 건조시켜 그라운드 필름을 제조하였다. 그리고 2액형 PU와 IPA/MWNT 3wt% 분산용액과 발포제를 사용하여 발포온도 $150^{\circ}C$에서 5분간 건조시켜 발포필름을 제조하였으며 이들의 전기적 특성과 역학적 특성을 조사하였다. 제조된 필름의 전기전도성은 전기저항측정기 KEITHLEY 8009를 사용하여 부피저항과, 표면저항을 각각 측정하여 확인하였으며, 필름의 마찰 대전압은 E.S.T-7 마찰 대전압 시험기를 이용하여 표면 마찰 대전압을 측정하여 확인하고, 필름의 물리적 특성은 인장시험기를 이용하여 breaking stress, breaking strain을 측정하였다. 필름단면의 CNT 발포특성은 주사전자현미경(SEM)을 사용하여 측정하여 발포특성과 물성과의 연관성을 확인하였다. 그 결과 필름의 전기적 특성은 PANI가 30% 함량일 때 전반적으로 낮은 저항값이 측정되었으며, 마찰대전압을 측정한 결과 대부분의 시료가 0에 가까운 낮은 값을 가졌다. 필름의 물리적 인장특성은 PANI가 10wt%의 함량일 때 가장 높은 절단강도를 가졌으며 분산용액의 혼용비에 따른 경향성은 나타나지 않았다. 필름의 단면형상을 확인하여 발포특성을 분석한 결과 PANI의 함량에 따라 발포 cell의 크기는 뚜렷한 경향성을 보이지 않았으나 30wt%의 PANI/DMF 분산용액 20part(gr)와 3wt% IPA/MWNT 분산용액 40part(gr)로 제조한 시료의 cell이 가장 균일하고 고르게 발포되었으며, 3.90E+06ohm으로 가장 낮은 표면저항 값으로 측정되어 가장 좋은 전기전도성을 가짐을 확인하였다.

  • PDF