• 제목/요약/키워드: 마이크로 믹서

검색결과 73건 처리시간 0.024초

엇갈림 배플 구조의 마이크로 채널 내 유동 및 혼합 특성에 관한 수치해석적 연구 (A NUMERICAL STUDY ON FLOW AND STIRRING CHARACTERISTICS IN A MICROCHANNEL WITH PERIODIC ARRAY OF CROSS BAFFLES)

  • 허성규;허영근;허형석;서용권
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2006년도 추계 학술대회논문집
    • /
    • pp.159-162
    • /
    • 2006
  • In the microfluidics devices the most important thing is mixing efficiency of various fluids. In this study a newly designed mixer is proposed to enhance the mixing effect with the purpose to apply it to microchannel mixing in a short future. This design is composed of a channel with cross baffles periodically arranged on the both bottom and top surfaces of the channel. To obtain the flow patterns, the numerical computation was performed by using a commercial code, ANSYS CFX 10.0. To evaluate the mixing performance, we computed Lyapunov exponent and obtained Poincare sections.

  • PDF

마이크로믹서에의 응용을 위한 batch type 초음파믹서의 혼합 상태 가시화 (Visualization for the mixing state of a batch-type ultrasonic mixer for its application to the microdevice)

  • 허필우;윤의수;고광식
    • 센서학회지
    • /
    • 제14권1호
    • /
    • pp.47-51
    • /
    • 2005
  • An active ${\mu}$-mixer is important in Bio-MEMS and ${\mu}$-TAS. The mixing state depends on some kinds of factors including the intensity of ultrasonic radiation. We have visualized the mixing state of the mixing chamber with radiation time and presented the influence of the driving voltage in this research. It will be possible to compare the performances of the ultrasonic radiation parts used in the active ${\mu}$-mixer using this method.

Dual-Gate MESFET를 이용한 분포형 주파수 혼합기의 설계 (Design of a Distributed Mixer Using Dual-Gate MESFET's)

  • 오양현;안정식;김한석;이종악
    • 전기전자학회논문지
    • /
    • 제2권1호
    • /
    • pp.15-23
    • /
    • 1998
  • 본 논문에서는 DGFET를 이용한 초고주파용 분포형 믹서가 연구되었다. 분포형 믹서 회로는 게이트, 드레인 전송선로와 입, 출력단에서 정합회로 및 DGFET들로 구성된다. RF와 LO신호가 각 게이트 전송선로의 입력 단에 인가되면, DGFET의 전달 컨덕턴스를 통해 드레인 전송선로로 전달되며, 각 드레인단의 출력된 신호들은 설계에 따라 동위상으로 더해지게 되고, 이러한 형태의 믹서는 변환이득을 개선할 수 있을 뿐만 아니라 각 소자의 임피던스가 전송선로에 흡수되므로 초광대역을 특성을 갖는다. 또한, 보다 높은 주파수까지 광대역 특성을 갖게 하기 위해서 각 전송선로의 입 출력 단에 m-유도 영상 임피던스 개념을 도입하여 입 출력 단을 정합 하였다, 이러한 분포형 믹서를 마이크로스트립 기판 위에 설계 및 제작하였고 광대역 특성 및 변환이득, RF/LO 분리도 등을 컴퓨터 시뮬레이션 및 실험을 통해 검증하였다.

  • PDF

마이크로 채널에서 두 유체 혼합 (Two-Fluid Mixing in a Microchannel)

  • 류임정;김병재;성형진
    • 한국전산유체공학회지
    • /
    • 제8권2호
    • /
    • pp.16-23
    • /
    • 2003
  • A numerical study of the mixing of two fluids(pure water and a solution of glycerol in water) in a microchannel was carried out. By varying the glycerol content of the glycerol/water solution, the variation in mixing behavior with changes in the difference of the properties of the two fluids(e.g., viscosity, density, diffusivity) was investigated. The mixing phenomena were tested for three micromixers: a square mixer, a three-dimensional serpentine mixer, and a staggered herringbone mixer. The governing equations of continuity, momentum and solute mass fraction were solved numerically. To evaluate mixing performance, a criterion index of mixing of mixing uniformity was proposed. In the systems considered, the Reynolds numbers based on averaged properties were 1 and 10. For low Reynolds number (Re = 1), the mixing performance varied inversely with mass fraction of glycerol due to the dominance of molecular diffusion. The mixing performance by diffusion deteriorated due to a significant reduction in the residence time of the fluid inside the mixers.

스토캐스틱 분자동역학 시뮬레이션을 통한 직사각형 마이크로 채널 내의 입자 확산 연구 (STOCHASTIC MOLECULAR DYNAMICS SIMULATION OF PARTICLE DIFFUSION IN RECTANGULAR MICROCHANNELS)

  • 김영록;박철우;김대중
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2008년도 학술대회
    • /
    • pp.204-207
    • /
    • 2008
  • Stochastic molecular dynamics simulation is a variation of standard molecular dynamics simulation that basically omits water molecules. The omission of water molecules, occupying a majority of space, enables flow simulation at microscale. This study reports our stochastic molecular dynamics simulation of particles diffusing in rectangular microchannels. We interestingly found that diffusion patterns in channels with a very small aspect ratio differ by dimensions. We will also discuss the future direction of our research toward a more realistic simulation of micromixing.

  • PDF

스토캐스틱 분자동역학 시뮬레이션을 통한 직사각형 마이크로 채널 내의 입자 확산 연구 (STOCHASTIC MOLECULAR DYNAMICS SIMULATION OF PARTICLE DIFFUSION IN RECTANGULAR MICROCHANNELS)

  • 김영록;박철우;김대중
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2008년 추계학술대회논문집
    • /
    • pp.204-207
    • /
    • 2008
  • Stochastic molecular dynamics simulation is a variation of standard molecular dynamics simulation that basically omits water molecules. The omission of water molecules, occupying a majority of space, enables flow simulation at microscale. This study reports our stochastic molecular dynamics simulation of particles diffusing in rectangular microchannels. We interestingly found that diffusion patterns in channels with a very small aspect ratio differ by dimensions. We will also discuss the future direction of our research toward a more realistic simulation of micromixing.

  • PDF

LIF Conforcal Microscope을 이용한 Y-channel 마이크로믹서의 최적설계 연구 (The Study of Optimum Design of Y-Channel Micro-Mixer by Using LIF Conforcal Microscope)

  • 김상우;현석호;신태석;이도형
    • 대한기계학회논문집B
    • /
    • 제33권5호
    • /
    • pp.311-317
    • /
    • 2009
  • Due to extremely small device size and velocity scale, mixing in microchannel take place very slowly by way of molecular diffusion transport. Mixing enhancement becomes a central issue in microfluidics for biomedical and chemical applications. In this work, The optimization results and validation through experiment and fabrication. In this efficient micromixer design, it is essential to evaluate mixing efficiency with good precision. Mixing efficiency for Y-channel micromixer is measured by fluorescence intensity using LIF(Laser Induced Fluorescence) Confocal Microscope. The Y-channel micromixers are fabricated with polydimethylsiloxane(PDMS). Nile Blue A is injected into the micromixer as a fluorescence dye for measuring of fluorescence intensity by He/Ne laser. Throughout the experiments and computer simulation, accurate mixing efficiency evaluation process for a PDMS Y-channel micromixer is established.

초미세 유체 제어 시스템 구현을 위한 마이크로 펌프와 밸브의 집적 (Characterization of Microfluidic system integrated with micropump and microvalve)

  • 유종철;허현정;최영진;강치중;김한수;이경일;신진국;김용상
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 C
    • /
    • pp.1645-1646
    • /
    • 2006
  • Micro ElectroMechanical Systems (MEMS) 기술을 이용한 초미세 유체 제어 시스템 (마이크로 펌프, 마이크로 밸브, 마이크로 채널, 마이크로 믹서 등)은 화학, 생명분야의 DNA 분석, 항원-항체 분석, 질병의 진단 등에 사용되는 lab-on-a-chip, micro total analysis system ($\mu$-TAS) 등에서 화학 및 바이오 유체를 제어하는 분석 시스템의 일부분으로서 사용되며 필수적으로 요구된다. 본 논문에서는 이러한 microchip을 구현하기 위해 초미세 유체 제어 소자인 마이크로 펌프와 밸브를 같은 기관 위에 polydimethylsiloxane (PDMS)와 indium tin oxide (ITO)-Glass를 사용하여 동일한 구조로 집적 하였다. 마이크로 펌프의 pumping rate은 인가 직류 펄스 전력의 주파수와 duty 비를 변화시켜 최적화하였다. 직류 펄스 전력 500 mW를 인가하였을 때 주파수 2 Hz, duty 비 7 %에서 약 $1.05{\mu}l/min$의 최대 유량이 측정되었다. 마이크로 밸브는 ITO 히터에 전력을 인가함으로서 유량의 on/off 제어가 잘 됨을 확인할 수 있었고 유체를 closing하기 위해 필요한 전력은 약 300 mW이다.

  • PDF