• 제목/요약/키워드: 마멸 기구

검색결과 49건 처리시간 0.018초

생산 및 설계공학부문

  • 김성청
    • 기계저널
    • /
    • 제43권8호
    • /
    • pp.64-73
    • /
    • 2003
  • 2002년도 한 해 동안 생산 및 설계공학 관련 분야를 중심으로, 소성가공, 절삭가공, 금형 및 사출성형, 용접 및 특수가공, 생산자동화 및 관리, CAD/CAM, 기계요소 및 기구설계, 공작기계 및 기계시스템설계, 지적설계 및 최적설계, 윤활 및 마멸, 생체공학, MEMS 등으로 분류하여 각 분야에서 그 동안 발전 개발하여 게재된 연구 및 실험 논문들을 중심으로 이들 분야에 대한 관련 동향등을 정리하면 다음과 같다.

  • PDF

유한요소해석에 의한 DLC 코팅면의 마멸기구에 대한 연구 (A Study on Wear Mechanism in Diamond-like Carbon Coated Surface by Finite Element Analysis)

  • 이준혁;박태조
    • Tribology and Lubricants
    • /
    • 제29권6호
    • /
    • pp.366-371
    • /
    • 2013
  • Various heat treatment and surface coating methods have been applied to machine parts. Nowadays, diamond-like carbon (DLC) coatings are widely used because of their excellent tribological characteristics. Despite the numerous studies on DLC-coated engineering surfaces, the exact wear mechanisms related to the coating thickness and elastic modulus have not been fully examined. In this study, a sliding contact problem between a small spherical hard particle and a DLC-coated steel surface is analyzed using a nonlinear finite element code, MARC. The maximum principal stress distributions and deformed surfaces are compared for different coating thicknesses and Young's modulus values. Plastically deformed surface shapes such as a groove and torus indicate that the most dominant wear mechanism for a DLC-coated surface is abrasive wear. Fatigue wear can also play a role in a case where the coating thickness is relatively large and the elastic modulus is high.

윤활시스템에서 마모메카니즘에 미치는 물리화학적 영향에 관한 연구

  • 최웅수;권오관;문탁진;유영홍
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 1988년도 제7회 학술강연회초록집
    • /
    • pp.28-30
    • /
    • 1988
  • 윤활시스템에서 마모는 상대적인 운동을 하는 두 물체사이에서 표면상태, 접촉조건 및 분위기등의 제요소들에 의해 발생되며, 형태학적으로 scuffing, scoring, pitting 및 fretting 등으로 분류된다. 윤활조건의 특성에 따라 미끄럼 접촉에서는 mild wear, severe wear로 구분되며, 이들의 마모 생성기구의 차이는 접촉상대속도, 하중 및 표면조도등의 정도에 기인된다. mild wear에서 severe wear 영역으로 전이될 때의 가혹한 조건에서 생성되는 마모현상을 scuffing wear라 하며, 이는 접촉면에서의 표면돌기의 직접접촉에 의한 cold welding 현상, 즉 local welds의 특성을 지닌 마멸형태로 정의한다. 이의 생성은 접점간의 하중 및 미끄럼 속도가 증가됨에 따라 온도상승에 기인되어 순간적으로 발생된 마찰열이 그 원인이 있으며, 기어, cam 및 tappet, 피스톤링 및 실린더 라이너 등의 마멸현상이 대표적인 예이다.

  • PDF

지르칼로이-4 튜브 프레팅 마멸 특성의 환경 의존성과 마멸기구 (Comparison of Fretting Wear Characteristics of Zircaloy-4 Tube in Light Water and in Air)

  • 조광희;김석삼
    • Tribology and Lubricants
    • /
    • 제15권1호
    • /
    • pp.83-89
    • /
    • 1999
  • The fretting wear behaviour of Zircaloy-4 tube used as the fuel rod cladding in PWR nuclear power plants has been investigated at the different test environment, in light water and in air as a function of slip amplitude, normal load, test duration and frequency. Zircaloy-4 tubes were used for both of oscillating and stationary specimens. A fretting wear tester was designed to be suitable for this fretting test. The wear volume and specific wear rate of Zircaloy-4 tube in water was greater than those in air under various slip amplitude. Delaminates and surface cracks were observed at low slip amplitude and high load of fretting test in water, but the traces of adhesion and plowing were observed at and above 200 Um. The water accelerates the wear of Zircaloy-4 tube at lower slip amplitude in fretting.

하드디스크의 표면 파손 기구에 관한 고찰 (Surface Damage Mechanism of Hard Disk)

  • 정구현;김대은;김상국
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1996년도 추계학술대회 논문집
    • /
    • pp.716-720
    • /
    • 1996
  • In this work the surface damage mechanism of hard disk was investigated. Experiments were peformed to simulate the contact during start and stop. Evidence of significant surface damage appeared after 20,000 cycles. It was found that despite higher hardness, the slider showed more signs of damage than the disk. Optical microscopy showed that the surface was damaged by abrasive action as well as adhesion of wear debris.

  • PDF

치과의술용 다이아몬드 전착공구의 마멸 (Wear of Diamond Dental Burs)

  • 이근상;임영호;권동호;소의열
    • 한국정밀공학회지
    • /
    • 제16권4호통권97호
    • /
    • pp.148-154
    • /
    • 1999
  • This study was carried out to verify grinding performance of dental diamond bur and investigate the possibility of AE application in dentistry field. Workpieces were made of acryl and bovine respectively for the experiments in this study. Grinding test was conducted to get the data of grinding resistance and specific grinding energy of four different types of diamond bur by using tool dynamometer. AE signal was acquired to verify grinding process in the AE measuring system. Tool wear was observed to find parameters about grinding characteristics of diamond bur by means of SEM picture. It was found that the wear of dental diamond bur could be detected with polishing of grinding material, removal of adhesive parts, wear of particles neighboring cutting nose, loss of material and elevation of temperature. The wear of B, C, D type diamond bur is due to wear and fracture of grain size. Abnormal state can be found through the behavior of AE signal in the grinding working. As a result, it is expected that forecast of abnormal state is possible using AE equipments under real time process.

  • PDF

플라즈마 코팅한 주조용 알루미늄합금의 마찰 및 마멸특성 (Friction and Wear Characteristics of Plasma Coated Surface of Casting Aluminum Alloy)

  • 채영훈;임정일;박준목;김석삼
    • 대한기계학회논문집A
    • /
    • 제21권5호
    • /
    • pp.791-799
    • /
    • 1997
  • The wear characteristics and wear mechanisms of plasma sprayed Al/sub 2/ O/sub 3/-40%TiO/sub 2/ and Cr/sub 2/O/sub 3/ deposited on casting aluminum alloy(AC4C) were investigated. Specimens were processed for various coating thicknesses. Ball on disk type wear tester was used for wear test. The scratch test on plasma sprayed coating surface showed that critical load to break the coating layer was greater than 40 N. The critical load increase with the increase of coating thickness of specimens. The friction coefficient of Cr/sub 2/O/sub 3/ coating layer was less than that of Al/sub 2/O/sub 3/-40%TiO/sub 2/ coating layer. The wear resistance of Cr/sub 2/O/sub 3/ coating layer was greater than that of Al/sub 2/O/sub 3/-40%TiO/sub 2/ coating layer. Microscopic observation of worn surfaces was made by SEM. SEM observation showed that the main mechanism of wear for Al/sub 2/O/sub 3/-40%TiO/sub 2/ coating layer was abrasive wear under 50 N. For the case of Al/sub 2/O/sub 3/-40%TiO/sub 2/ coating layer, as the surface cracks perpendicular to sliding direction propagated, the wear debris was generated in wear track. However, the main mechanism of wear for Cr/sub 2/O/sub 3/ coating layer was brittle fracture under 150 N.

시일과 스틸면 사이에 구형입자가 있는 접촉문제의 해석 (Contact Analysis of a Spherical Particle Between Elastomeric Seal and Steel Surface)

  • 박태조;조현동
    • 대한기계학회논문집A
    • /
    • 제34권2호
    • /
    • pp.161-166
    • /
    • 2010
  • 본 논문에서는 시일 설치면에서의 마멸발생기구를 정확하게 조사하기 위한 연구의 일환으로 미세입자가 시일과 스틸면 사이에 존재하는 경우의 접촉문제를 비선형문제해석 프로그램인 MARC를 사용하여 해석하였다. 이 결과, 시일의 재질은 스틸면에서의 응력분포와 변형형상에 아주 큰 영향을 미쳤다. 특히, PTFE와 같이 탄성계수가 높은 시일인 경우에 스틸 표면은 국부적으로 항복상태에 도달할 뿐만 아니라 시일을 제거한 후에도 영구변형과 함께 상당한 크기의 압축/인장 잔류응력이 존재하였다. 따라서, 시일과 스틸면 사이에 경질입자가 존재할 경우에는 연삭마멸과 함께 피로마멸이 발생할 수 있음을 확인하였으며, 다양한 설계변수에 대한 추가연구가 요구된다.

파인 세라믹 ($Al_2O_3$)의 被削性에 관한 硏究 (A Study on the Machinability of Fine Ceramics (($Al_2O_3$)))

  • 김성겸;이용성
    • 대한기계학회논문집
    • /
    • 제13권4호
    • /
    • pp.604-610
    • /
    • 1989
  • 본 연구는 알루미나계 세라믹의 소결 다이아몬드 공구로 절삭시의 칩의 형태 와 절삭저항을 관찰하였다. 절삭 양식은 건식과 습식으로 하고, 여러 가지 적삭조건 에 따른 flank 마멸의 진행과정, 가공면의 표면거칠기에 미치는 영향 및 가공면의 크랙 상태를 조사형 현미경으로 확대 검출하여 가공상태를 정밀하게 조사, 측정하였 다.

플라스틱성형용 KP-4M강의 마멸특성 및 이의 기구에 관한 연구 (A Study on the Wear Characteristics and the Mechanism of KP-4M Steel for Plastic Molding)

  • 박흥식;전태옥;김동호
    • Tribology and Lubricants
    • /
    • 제12권1호
    • /
    • pp.22-28
    • /
    • 1996
  • This study was undertaken to investigate the dry wear characteristics and mechanism of KP-4M steel for plastic molding against SKD 61 hardened by heat treatment. The wear test was carried out under different conditions such as sliding speed, contact pressure, sliding distance, with frictional tester of pin on disc type. The wear loss on variation of sliding speed was little in lower speed range below 0.5 m/sec and in higher speed range above 1.5 m/sec,'but wear loss was high in intermediate speed range. The critical sliding speed, which showed the maximum value of specific wear rate, became lower with increased contact pressure. Increasing the contact pressure, the critical sliding distance Lcr which the wear mechanism changes from severe wear to mild wear was increased due to the decrease of oxidation reaction velocity. Through this study we suggested a model of generation and elimination process of wear debris of KP-4M steel for plastic molding.