  • The purpose of this study is to evaluate the impacts of finishing materials' VVOCs and VOCs emission rates on indoor air quality of Apartment. VOCs emission rate of multi-layer finishing is predicted using the effective diffusion coefficient of each materials, and then the prediction is compared with Mock-up test and sample apartment house. From the results, the prediction of multi-layer finishing using the effective diffusion coefficient show good relation with the measured values.

  • PDF

Experimental Study on the Flash Over Delay Effects according to the Prevention of Flame Spread between Composite Material Panels (복합자재의 패널 간 화염확산방지에 따른 플래시오버 지연 효과에 대한 실험적 연구)

  • Kim, Do-hyun;Cho, Nam-Wook
    • Fire Science and Engineering
    • /
    • v.31 no.2
    • /
    • pp.1-8
    • /
    • 2017
  • A sandwich panel is a composite material composed of a double-sided noncombustible material and insulation core which is used in the inner, outer walls, and roof structure of a building. Despite its excellent insulation performance, light weight and excellent constructability, a flame is brought into the inside of the panel through the joint between the panels, melting the core easily and causing casualties and property damage due to the rapid spread of flame. The current Building Law provides that the combustion performance of finishing materials for buildings should be determined using a fire test on a small amount of specimen and only a product that passes the stipulated performance standard should be used. This law also provides that in the case of finishing materials used for the outer walls of buildings, only materials that secured noncombustible or quasi-noncombustible performance should be used or flame spread prevention (FSP) should be installed. The purpose of this study was to confirm the difference between the dangers of horizontal and vertical fire spread by applying FSP, which is applied to finishing materials used for the outer walls of buildings limitedly to a sandwich panel building. Therefore, the combustion behavior and effects on the sandwich panel according to the application of FSP were measured through the construction to block the spread of flame between the panels using a full scale fire according to the test method specified in ISO 13784-1 and a metallic structure. The construction of FSP on the joint between the panels delayed the spread of flame inside the panels and the flash over time was also delayed, indicating that it could become an important factor for securing the fire safety of a building constructed using complex materials.

Emission Characteristics of Volatile Oranic Compounds by Finishing Materials in a Newly Constructed Wooden House (신축목조주택 내 마감자재에 따른 휘발성유기화합물(VOCs)의 방산특성)

  • Lee, Hee-Young;Park, Sang-Bum;Park, Jong-Young;Lee, Sang-Min
    • Journal of the Korean Wood Science and Technology
    • /
    • v.35 no.6
    • /
    • pp.83-90
    • /
    • 2007
  • This study aimed at examining the effect of rooms decorated by eco-friendly finishing materials in a newly built wooden house on the emission of indoor air pollutions. According to the results of examination, the levels of benzene, toluene, ethyl benzene and styrene in all the rooms were below criteria of indoor air quality of newly-constructed houses. The levels of natural volatile organic compounds (NVOC), anthropogenic volatile organic compounds (AVOC) and total volatile organic compounds (TVOC) in room R1-1 which had Hwangto wall covering on it, were relatively higher than in room phytoncide wallpaper covered R2-1. The room R2-2 where bamboo charcoal panel used for wall covering showed higher level of AVOC compared to the room R1-2. Living room R1-3 was found to contain less TVOC, compared to the other four rooms. In addition, the ratio of NVOC to TVOC in the living room was higher than in the other rooms. This seemed to be attributed to Cryptomeria Japonica the living room finished material.

A Study on the Current Condition of Quality Differentiation of the Apartment Unit Quality Planned by Domestic Housing Companies (국내주택업체의 단위세대 품질의 차별화 실태조사연구)

  • Cho, In-Sig;Park, Tae-Keun
    • Proceedings of the Korean Institute Of Construction Engineering and Management
    • /
    • 2007.11a
    • /
    • pp.441-445
    • /
    • 2007
  • The mass housing supply policy of the government has resulted in the customer-centered market, and thereby the age of quality competition in the industry. In line with this trend of quality competition, therefore, this preliminary study aims to investigate the requirements of housing product planning to live up to the needs of customers in terms of quality, and thus analyze the types of quality differentiation of a housing product unit in our housing market. It turned out that many cases attempted differentiation in such ways as merely using luxurious finishing materials and instantly popular environment-friendly materials, and combining partial and limited household items with architectural elements of the facility system. The result of this study shows that the differentiation plan of housing product should be customer-centered, and therefore, focus on quality differentiation through organic combination of architecture-oriented plane and interior elements with technology-oriented facility and product elements. Hereby, in the future, housing product planning should include sustainable differentiation plans with reconsideration of concepts that customers have, and the needed procedure.

  • PDF

Preparation of Natural Wall Paint by Using Sericite Clay (견운모를 이용한 벽마감용 천연페인트 제조)

  • Kim, Munui;Lalhmunsiama, Lalhmunsiama;Lee, Seung-Mok;Jin, Kang-Jung
    • Applied Chemistry for Engineering
    • /
    • v.28 no.5
    • /
    • pp.501-505
    • /
    • 2017
  • Due to the rapid urbanization and increased population, there is an increase in airtight nature of buildings which causes serious indoor air pollution. Among several indoor air pollutants, volatile organic compounds (VOCs) emitted from paint are of major concern. Therefore, there is an urge for the development of environmental friendly paint products. In this wok, a natural wall paint (NWP) was prepared by utilizing a natural clay material "sericite" as a main component. A small chamber test was carried out to identify the toxic substances release from NWP and the results were compared with two eco-friendly commercial paints. The total VOCs were detected in trace level inside the test chamber and their concentrations were below the recommended indoor air quality standards. Toluene was not detected for NWP, whereas formaldehyde was observed in trace level. The toxicity index results were compared with two commercial paints and found that NWP exhibited less harmful gas emission. Based on certification rating of building materials, NWP can be classified as the first grade of building materials. Due to the above advantages, the use of sericite as a major component in NWP will be a useful technique to maintain the indoor air quality.

Actual Use Pattern of Environment-friendly Finish Materials in Recently-Constructed and Remodeled Apartment Houses (공동주택 유형별 친환경 마감재 사용 실태분석 연구)

  • Lee, Ji-Soon
    • KIEAE Journal
    • /
    • v.11 no.1
    • /
    • pp.39-45
    • /
    • 2011
  • The concepts of interior design work have set forward an aesthetic and functional proposition to be answered by those who design spaces. The available range of suitable materials for interior use appears to be almost inexhaustible in this day and age. Now a day, relatively new fields of study on environmental-friendly interior examine humans'innate affinity for health and explore its implications for architecture and the built environment. A growing field of research suggests that spaces' relationship to aesthetics and environment can either help or hinder their occupants' health and wellness, productivity, and even their creativity. This paper presents several examples of already built apartment houses in practice, and discusses the demand of users of the spaces for health and sustainable environment, deepening the relationship between newly-constructed spaces and the remodeled ones. The considerations to some new and contemporary materials from the aspect of healthy indoor architecture design are presented in this paper. Designers need to rethink the conventional and high-tech interior environment in apartment houses with respect to perceived air quality, material emissions, and odors. The future of interior design is oriented on light shapeable materials which are able to create a unique memorable atmosphere. The primary assignment in accepting recent materials and proceedings is our responsibility to creating proposals, that are mainly safe, hygienic and environmentally proper.

Measurement of Air Contaminants Emission from Interior Finish Material (실내 건축 마감자재의 공기오염물질 방출량 분석)

  • Kim, Yun-Deok;Lim, Soo-Young
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.14 no.1
    • /
    • pp.58-65
    • /
    • 2007
  • For the moderns who spend more than 80% of the time inside a building, interior environment became important since it directly affects their health. Recently as noxiousness of the air contaminants of the interior space stood out as well as the above trend, the Ministry of Environment enacted a lawto maintain the interior air quality at certain level of standard in the multi use facility and newly constructed apartment. To make the indoor air clean, removal technology of various contaminants should be developed and interior materials with chemical treatment should be restrained. In other words, selection of interior finish affects indoor air quality from the initial design stage to the construction stage. However, only limited contaminants emission data of building materials are supplied by related companies. There is no average contaminants emission data for overall materials. Moreover, high cost and equipments for one time measurement of VOCs emission of interior finish are the obstacles of active research and data measurement. Therefore, this paper searched the current condition of average VOCs & HCHO emission of various interior finish based on the study requested to research center from the building material company through Stands Test Method for Indoor Air Quality.

The Comparison of Room Acoustics of Elementary School Classrooms (초등학교 교실의 음환경 비교연구)

  • Moon Kyu-Chun;Park Kye-Kyun;Yeon Chul-Ho;Haan Chan-Hoon
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • autumn
    • /
    • pp.293-296
    • /
    • 2001
  • 1990년대 중반 이후 우리나라 초등학교 교실은 열린교육과 다양성을 추구하는 새로운 열린교실을 표방하고 진행되고 있다. 또한 건축설계에 있어서도 과거의 종합 표준설계에 의하지 않고 각 학교마다 별도의 건축설계에 따라 지어지고 있다. 본 논문의 목적은 현재의 초등학교 교서의 차음환경을 조사하고 새로이 지어진 교사의 교실과 열린교실의 실내 음환경을 조사하여 현재 상황을 분석평가하고 이에 대한 대안을 제시하고자 하는 것이다. 이를 위하여 건축시공연대가 다른 초등학교 3개 학교를 선택하여 단위교실에서의 실내음향인자(RT60, C80, D50, RASTI)와 인접교실과의 차음성능(TL)을 측정하였다. 또한 해당교실의 학생과 교사에 대하여 설문조사를 실시하였다. 각 측정은 외부와 복도에 인접한 창문의 개폐여부와 실내의 위치별로 이루어 졌다. 실험결과, 열린교육에 따라 가변적 교실의 구성은 기존의 교실보다 차음성능이 평균$5\sim6dB$ 낮은 것으로 나타났다. 또한 신축교사의 RASTI값(0.73)이 10년 이상 된 학교(0.70)나 열린교실(0.64)보다 높은 것으로 나타났다. 음성명료도(D50) 역시 일반 신축교사가 열린교실 보다 높게 나타났다. 이것은 실의 기밀과 내부바닥의 마감자재로 비롯되었으며 최근의 열린교실은 음의 차음과 실내명료도에서 열악한 것으로 결론되었다.

  • PDF

Real Survey on Interior Surface Area and Applied Finishes in Recently-Planned Apartment Houses (공동주택의 실내부 표면적 및 사용 마감재 구성 실태분석)

  • Lee, Ji-Soon
    • KIEAE Journal
    • /
    • v.10 no.6
    • /
    • pp.115-121
    • /
    • 2010
  • This paper is an outgrowth of many years of practicing real interior work projects and one of my responses to the question not only about the actual dimension of interior work surface but also about the classification of contemporary finishing materials in basic interior project of high-rise apartment houses. For this purpose, 8 conventional apartment units which are already-built or designed have been surveyed and the results are interpreted in the form of proportion of space and finishes. The data can be applied to make up a schematic design in the selection of environment-friendly interior works and assessment of the degree of sustainability. For further study, the basic data provided here can be used as an index to differentiate the occupants' desire toward green interior design for their own apartment spaces, comparing to the conventional interior work in the Korean market. Not surprisingly, wall paper is dominated to make the interior surface in apartment houses. In the percentile of the utilization of finishing materials, wood-flooring and coating materials like wet paint also ranked at the upper position.

A Study on the Ways of Securing the Effectiveness of Field Flame Retardant Coating Process (현장방염처리제도의 실효성 확보 방안에 관한 연구)

  • Park, Sung-Hyun;Baek, Eun-Sun
    • Fire Science and Engineering
    • /
    • v.25 no.2
    • /
    • pp.95-100
    • /
    • 2011
  • The ultimate purpose of this study is to improve the irrational system related to flame retardant coating performance test of field flame retardant coating articles and to secure the reliability of flame retardant coating through rational flame retardant coating test. To achieve this, the analysis was conducted on the interior finishing materials used in the interior fields and the trends of recent field flame retardant coating, based on the results of flame retardant coating performance test of field flame retardant coating articles which the first-line fire stations have recently conducted. And I attempted to present the methods of field flame retardant coating performance test suitable to current realities and the ways of improvement for securing reliability by analyzing the problems with the methods and procedures of field flame retardant coating articles and the registration system of flame retardant coating business.