• Title/Summary/Keyword: 링형

Search Result 75, Processing Time 0.02 seconds

Compact Antenna Design for the UWB Lower Half-Band WVAN Gbps Data-Rate Transceiver (UWB 하반 대역 WVAN Gbps 데이터 전송률 트랜시버용 소형 광대역 안테나의 설계)

  • Eom, Da-Jeong;Lim, Dong-Jin;Kahng, Sung-Tek;Lee, Seung-Sik;Choi, Sang-Sung
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.23 no.3
    • /
    • pp.283-291
    • /
    • 2012
  • In this paper, a compact antenna is designed for the UWB lower half-band WVAN Gbps data-rate transceiver. The proposed antenna broadens the bandwidth less than -10 dB by placing the ring stubs and an open stub on the rectangular monopole above the partial ground and creating multiple resonant current paths. The designed antenna goes through the electromagnetic simulation and is fabricated and the implemented antenna has the characteristics of the return loss lower than -10 dB, the antenna gain greater than 5 dBi, and the efficiency over 80 % in the UWB lower half-band ranging from 3.197 GHz to 4.732 GHz. Therefore, it is thought that the proposed antenna is suitable for the size-reduced and excellently performing wireless communication transceiver.

Development and Application of a Self-management Program based on Prothrombin INR Monitoring for Patients with Cardiac Valve Replacement (심장판막수술 후 프로트롬빈 INR 모니터링형 자가관리프로그램 개발 및 적용)

  • Jeon, Hyun Rye;Park, Jeong Sook
    • Journal of Korean Academy of Nursing
    • /
    • v.45 no.4
    • /
    • pp.554-564
    • /
    • 2015
  • Purpose: The purpose of this study was to develop and evaluate a self-management program based on INR monitoring for patients with cardiac valve replacement. Methods: This program was comprised of five weekly sessions based on Sousa's Enhance-Behavior Performance Model. The first session included individual teaching, and the other four sessions included Prothrombin Time International Normalized Ratios (PT INR) self-monitoring, telephone counseling and self-management checklist recording. Participants were patients who had cardiac valve replacement. They were randomly assigned to the experimental or control group. Sixteen in the experimental group participated in the self-management program and seventeen in the control group participated in general care. Self-management knowledge, self-efficacy, self-management behavior and PT INR were measured as dependent variables. Data were analyzed using Mann Whitney U-test, t-test and ANCOVA. Results: The experimental group showed significantly higher post-test scores in self-management knowledge (t=5.86, p<.001), self-efficacy (F=18.32, p<.001), and self-management behavior (t=3.44, p=.002) compared to the control group. Also, the experimental group showed significantly higher frequency in maintaining the treatment range of PT INR compared to the control group (${\chi}^2=4.80$, p=.028). Conclusion: The results of the research on the self-management program based on PT INR monitoring showed that it is effective in improving self-management knowledge, self-efficacy, and self-management behavior as well as maintaining treatment range of PT INR of patients with cardiac valve replacement.

Flexural Design and Experiments on Reinforced Concrete Filled PHC Pile (철근 콘크리트 충전 PHC말뚝의 휨 설계 및 성능 평가)

  • Kim, Jeong-Hoi;Jung, Hae-Kwang;Park, Young-Shik;Min, Chang-Shik
    • Journal of the Korea Concrete Institute
    • /
    • v.29 no.4
    • /
    • pp.353-360
    • /
    • 2017
  • The objective of this study is theoretical and empirical evaluation of the flexural performance of concrete filled pretensioned spun high strength concrete pile with ring type composite shear connectors (CFP pile). The specimens are comprised of standard CFP pile, PHC pile+composite shear connector+filed concrete (CFP-N-N), standard CFP pile with $1^{st}$ reinforcements (H13-8ea), and standard CFP pile with $1^{st}$ and $2^{nd}$ reinforcements(H19-8ea). Flexural performance evaluation results showed that the ductility is improved with increased steel ratio, which leads to the increased maximum load by 46.4% (with $1^{st}$ reinforcement) and 103.9% (with $1^{st}$ and $2^{nd}$ reinforcements) compared to standard CFP ( CFP-N-N). Comparing with the predicted ultimate limit state values of the CFP pile design method and the experimental results, the design method presented in this study is reasonable since safety factor of 1.23 and 1.40 times for each reinforcement step are secured.

A Study on the Taegeuk Shaped Directional Coupler with Improved Power Split Ratio (개선된 전력 분배율을 갖는 태극형 방향성 결합기에 관한 연구)

  • 양규식;오양현;이종악
    • The Proceeding of the Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.2 no.2
    • /
    • pp.19-24
    • /
    • 1991
  • This paper propose a new taegeuk shaped directional couper and verify the possibility of high power division rate in those directional coupler through the experiments. We took the taegeuk shaped structure in those proposed directional coupler to utilize a $3\lambda/4$ section of hybrid ring directional coupler actively, and calculated the branch admittances, which satisfied the condition of perfect matching and isolation in the center frequency, by even odd mode analyzing methodes. On the result, we knew that it can be realized a much higher power division rate than reported result in same circuit area within the producible resistance limit in the microstrip line, made the taegeuk shaped directional couplers with 0, 8, 16 dB power split ratio in the 10 GHz frequency using CGP - 502 plate, and confirmed the validity of theory through the experiments.

  • PDF

Characteristics of active optical ring network and performance evaluation in Bandwidth on Demand (능동형 광 링 네트워크의 특징 및 요구 대역폭에 따른 성능 분석)

  • Lee Sang-Wha;Song Hae-Sang
    • Journal of the Korea Society of Computer and Information
    • /
    • v.10 no.6 s.38
    • /
    • pp.209-218
    • /
    • 2005
  • In this paper, we present an Active Optical Network(AON) . The AON uses the Dense Wavelength Division Multiplexing(DWDM) from optical communication access network of ring type, and will be able to provide the smoothly service in the Bandwidth on Demand by using DWDM. It supports the connection of the multiple wavelength and the Sub-Carrier from the optical gigabit ethernet switch. The Wavelength Add Drop Multiplexer(WADM) extracts a specific wavelength, and composes a node of the ring network. The specific wavelength becomes demultiplexing in the Sub-Carrier and it is distributed in the user The active connection of optical gigabit ethernet switch where the distribution of access network is started and access terminal connection equipment is possible. By the BoD from the AON it compares the buffer size which changes, and it analyzes. Also the Time delay of bit compares with the throughput of server The limit of amount of time is decided. Consequently it will be able to realize the dynamic use protocol and an efficient algorithm of the network.

  • PDF

The Vibration Characteristic Improvement by Mode Variation of Ring Type Ultrasonic Motor (리형 초음파모터의 모드가변에 따른 진동특성 개선)

  • 윤신용;김수석
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.2
    • /
    • pp.115-124
    • /
    • 2004
  • This paper suggested the vibration characteristic improvement by variation mode of ring type ultrasonic motor. Design for the piezoelectric ceramic and elastic body of stator were calculated by the finite element method(FEM) that consider the resonance frequency, vibration mode and coupling efficiency etc. Through the result of vibration analysis from 6 order mode to 8 mode, the 7 order mode was gained very an excellent results that it was the coupling efficient, minimum power loss and bending vibration value. Here over 7 order mode, was acquired that an output current for input voltage was very a large increased results. The result of vibration calculation, from thickness 0.5[mm] to 2[mm], know the fact that the vibration displacement at 0.5[mm] is an high value too. From such analysis result, this paper was manufactured the ultrasonic motor of outer diameter 50[mm], inter 22[mm] having the about 43.86[KHz] resonance frequency. We have gated that a simulation result is 42.2[KHz] and an experiment result is 43.86[KHz]. Then, a propriety of this paper was established the result almost similar to though comparison, investigation of simulation and experiment result.

The Resistance Characteristics and Reliability Evaluation of an Insulation Ring Type of Corrugated Stainless Steel Tubing(CSST) (절연링형 금속플렉시블호스(CSST)의 저항 특성 및 신뢰성 평가)

  • Lee, Jang-Woo;Kim, Jeom-Sik;Choi, Chung-Seog
    • Journal of the Korean Society of Safety
    • /
    • v.31 no.6
    • /
    • pp.25-31
    • /
    • 2016
  • This paper has analyzed the structure, applicable regulations and the resistance characteristics of insulation ring type of CSST (Corrugated Stainless Steel Tubing for Gas). With the flammability test conducted in accordance with KS C IEC 60811-1-1, the evaluation of insulation resistance, temperature characteristics, and reliability has been conducted. An insulation ring type CSST consists of protective coating, tube, nut, insulation ring, packing, socket, and ball valve. Connecting an insulation ring type CSST to gas tubings for gas appliance is not permitted, moreover, the product shall be installed inside a sleeve pipe in case of buried installation such as the ceiling. Damages on protective coating and tube were detected when fire was applied to the test sample with a portable torch for 60 seconds. The insulation resistance of a normal product was $49.59M{\Omega}$, while that of the product completed the flammability test reduced to $9.21M{\Omega}$. The mean insulation resistance within the confidence Interval of 95% using the mini tap program 17 was $49.59M{\Omega}$ and the mean insulation resistance within the confidence interval reduced to $9.21M{\Omega}$. In the normal distribution analysis of 95% confidence interval, the value-P of the normal product was stable at 0.075 and AD(Anderson-Darling) statistic value was turned out to be 0.063, which is very normal, and the standard deviation was analyzed as 0.2586. The value P of the product completed the flammability test resulted in 0.005, the AD was 1.355 and the standard deviation reduced to 0.07908.

Design of a broadband CP antenna for RFID readers (RFID 리더용 광대역 원편파 안테나 설계)

  • Lee, Jong-Ig;Yeo, Junho;Park, Jin-Taek
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.19 no.8
    • /
    • pp.1759-1764
    • /
    • 2015
  • In this paper, we considered a design method of a circular polarization (CP) antenna for UHF (ultra high frequency) RFID (Radio Frequency IDentification) readers. The antenna is a dual-fed circular microstrip patch which produces right-handed CP. Quadrature hybrid coupler is used for dual feeding. The outputs of the coupler and circular patch are connected through copper wires, and the inductive reactance produced by the connecting wires is compensated by a ring-shaped slot inserted inside the circular patch. The effects of the geometrical parameters of the proposed antenna on the antenna performance are examined, and the parameters are adjusted to be suitable for the operation in North American UHF RFID band (902-928 MHz), which includes domestic UHF RFID band. The antenna is fabricated, and the experiment results reveal a frequency band of 854-993 MHz for a voltage standing wave ratio < 2. The fabricated antenna is connected to a commercial RFID reader, and it showed a good performance of tag identification.

Analysis of fault current in offshore wind farm ccording to the grid connection method (해상풍력 발전단지의 전력망 연계방식에 따른 고장전류 분석)

  • Ahn, Jin-Hong;Kim, Eel-Hwan
    • Journal of IKEEE
    • /
    • v.24 no.3
    • /
    • pp.691-698
    • /
    • 2020
  • The installation cost or the magnitude of the fault current varies depending on the grid connection method of the offshore wind farm. Therefore, there is a need for an efficient power grid connection method considering the capacity and location of the complex. In particular, most power cables in offshore wind farms use 3-core considering cost and efficiency. In the event of a failure such as a short circuit, the entire cable must be replaced, which can lead to significant losses in terms of cost, considering repair costs and turbine downtime. Therefore, in this paper, a radial, ring, and molding method is introduced into a 100 MW wind farm to be installed at Jeju offshore, and a three-phase short circuit failure is performed using a PSCAD/EMTDC program to perform computer analysis. I would like to propose a suitable power grid connection method.

Non-uniform Deblur Algorithm using Gyro Sensor and Different Exposure Image Pair (자이로 센서와 노출시간이 다른 두 장의 영상을 이용한 비균일 디블러 기법)

  • Ryu, Ho-hyeong;Song, Byung Cheol
    • Journal of Broadcast Engineering
    • /
    • v.21 no.2
    • /
    • pp.200-209
    • /
    • 2016
  • This paper proposes a non-uniform de-blur algorithm using IMU sensor and a long/short exposure-time image pair to efficiently remove the blur phenomenon. Conventional blur kernel estimation algorithms using sensor information do not provide acceptable performance due to limitation of sensor performance. In order to overcome such a limitation, we present a kernel refinement step based on images having different exposure times which improves accuracy of the estimated kernel. Also, in order to figure out the phenomenon that conventional non-uniform de-blur algorithms suffer from severe degradation of visual quality in case of large blur kernels, this paper a homography-based residual de-convolution which can minimize quality degradation such as ringing artifacts during de-convolution. Experimental results show that the proposed algorithm is superior to the state-of-the-art methods in terms of subjective as well as objective visual quality.