• Title/Summary/Keyword: 릴레이 제어

Search Result 127, Processing Time 0.026 seconds

A Range-based Relay Node Selecting Algorithm for Vehicular Ad-hoc Network (차량 애드혹 네트워크를 위한 영역 기반 릴레이 노드 선택 알고리즘)

  • Kim Tae-Hwan;Kim Hie-Cheol;Hong Won-Kee
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.43 no.9 s.351
    • /
    • pp.88-98
    • /
    • 2006
  • VANET has several different characteristics from MANET such as high mobility of nodes and frequent change of node density and network topology. Due to these characteristics, the network topology based protocol, often used in MANET, can not be applied to VANET. In this paper, we propose an emergency warning message broadcast protocol using range based relay node selecting algorithm which determines the minimal waiting time spent by a given node before rebroadcasting the received warning message. Because the time is randomly calculated based on the distance between sender node and receiver node, a node chosen as a relay node is assured to have a minimal waiting time, even though it is not located at the border of radio transmission range. The proposed emergency warning message broadcast protocol has low network traffic because it does not need to exchange control messages for message broadcasting. In addition, it can reduce End-to-End delay under circumstances of low node density and short transmission range in VANET.

An analysis of the PID controller applied to DCS for boiler in thermal power plant (화력발전소 보일러 분산제어시스템에 적용된 PID 제어기의 성능 분석)

  • Lee, Chan-Ju;Lee, Joo-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 1999.07b
    • /
    • pp.874-876
    • /
    • 1999
  • 화력발전소 제어는 디지털 분산제어시스템에 의해서 이루어지고 보일러의 각종 프로세스는 대부분 PID제어기에 의해 제어되므로 PID제어기의 최적 조정은 보일러 프로세스의 안정적 운전에 가장 중요한 요소라고 볼 수 있다. 이러한 PID제어기는 분산제어시스템 제작사에 따라 구현방법을 달리하고 있으므로 PID제어기의 최적조정을 위해서는 구현된 PID제어기의 알고리즘을 이해하는 것이 필요하다. 본 논문에서는 먼저 화력발전소 보일러 디지털 분산제어시스템의 국산화 개발품에 채용된 PID제어기와 화력발전소에서 사용 중인 주요 외국 제작사별 PID제어기의 알고리즘에 대하여 기술한다. 임의의 모델링 된 프로세스에 대하여 릴레이 피드백을 이용하여 임계진폭과 임계주기를 구하고 Ziegler-Nichols 주파수응답법을 이용하여 적합한 PID제어기 파라미터를 산출한 후 각각의 PID제어기에 산출된 파라미터를 적용 시뮬레이션하여 PID제어기들의 성능을 비교 분석하고자 한다.

  • PDF

A Study on the Vending Machine Remote Control through Internet (인터넷을 통한 자판기 원격제어 구현 연구)

  • Lee, Yang-Weon;Kim, Mi
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2001.10a
    • /
    • pp.537-540
    • /
    • 2001
  • As giving IP on electric home appliance like as TV, Air-conditioner, etc., with the development of electric products and home networking, it has been possible to communicate through the Internet. In this paper, we proposed and developed the system which is possible to control the commercial vending machine using embeded internet card through internet. We implemented the basic circuit and application program for TCP/IP communication program by Java applet.

  • PDF

400kHz 페라이트 유도결합 플라즈마를 위한 임피던스 매칭 네트워크

  • Jo, Seong-Won;Bang, Jin-Yeong;Lee, Yeong-Gwang;Jeong, Jin-Uk
    • Proceedings of the Korean Society Of Semiconductor Equipment Technology
    • /
    • 2007.06a
    • /
    • pp.63-71
    • /
    • 2007
  • 현재 반도체 산업에서 플라즈마는 다양한 공정에 적용되고 있으며, 고집적 대면적 공정을 위한 다양한 플라즈마원들이 개발 중에 있다. 이 중 ICP는 현재 고밀도 플라즈마를 요구하는 공정에서 널리 쓰이고 있는 플라즈마원이다. 그러나 ICP는 안테나와 플라즈마 사이의 결합이 낮아 안테나의 전압과 전류가 높으며, 대면적에 적용하기 어려운 디자인 등의 여러 가지 문제점 들을 가지고 있는데, 이러한 ICP의 문제를 해결하기 위한 방법으로 강자성체를 ICP에 응용하는 플라즈마원이 연구되어 왔고 일부 장치에 쓰이고 있다. 이것은 ICP의 많은 문제들을 해결하면서도 여러 가지 장점을 가지는 것으로 평가되고 있다. 강자성체를 이용한 ICP는 플라즈마와 안테나의 결합계수가 1에 가깝기 때문에 강자성체 ICP에서는 간편한 변압기 임피던스 매칭이 적용 가능하다. 이 논문에서는 릴레이를 이용하여 변압기의 권선수를 제어하는 방식을 통해 새로운 임피던스 매칭이 제안되었다. 간단한 매칭 시스템을 구현하여 권선비가 바뀌었을 때 특성을 분석하였다. 2-채널 릴레이를 사용할 때 임피던스 매칭이 가능하였고, 디지털 회로와 마이크로콘트롤러를 사용하여 디지털 임피던스 매칭 시스템을 구현하였다.

  • PDF

Design and Implementation of Web Server for Controlling IoT Module Power (IoT 모듈 전원 제어를 위한 웹서버 설계 및 구현)

  • Kim, Ji-Seong;Jang, Si-Woong
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2019.05a
    • /
    • pp.115-117
    • /
    • 2019
  • 현재 우리나라는 지속되는 인구의 고령화와 단순 노동인구의 저하 등의 이유로 곳곳에 노동력이 부족한 상황이다. 그로인해 노동력을 대신할 기계들과 자동화 시스템이 많이 개발되었고, 발전해 나가고 있다. 본 논문의 웹서버는 IoT모듈의 전원을 무선통신을 통해 제어함으로 전원의 on/off기능을 통해 원거리에서 제어할 수 있는 방법으로 인력을 감소시킬 수 있다. 본 논문에서는 아두이노의 릴레이모듈, WiFi 모듈, 무선통신 웹서버를 통해 IoT 모듈의 전원을 제어하는 방법을 제안한다. HTTP 통신을 이용하여 웹서버에서 현재 on/off 제어 데이터를 IoT 모듈에서 읽어갈 수 있게 하고, IoT 모듈은 웹서버에서 읽어온 정보를 기반으로 작동하고 웹 서버로 자신의 정보를 전달한다.

  • PDF

The Design of a I/O Circuits for Driving and Monitoring of the Diesel Generator for Emergency (비상용 디젤 발전기 구동 및 모니터링을 위한 입출력 회로 설계)

  • Joo, Jae-Hun;Kim, Jin-Ae;Choi, Jung-Keyng
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.13 no.8
    • /
    • pp.1491-1496
    • /
    • 2009
  • This paper presents an digital based input/output interface circuit for controlling and monitoring the Diesel Engine Generator for emergency. In order to monitor and control of the Emergency Diesel Engine Generator, controlling and monitoring circuits need 5 analog input channels, 2 pick-up coil measuring circuits, 10 digital input channels containing Broken Wire Detect function, and 7 relay control signal output channels. This system performs signal processing of input signal taking advantage of simple filter circuit, photo-coupler and comparator circuit at analog input parts, and output signals for main relay is designed acting by double control, so it prevents malfunction completely. And it improves accuracy of speed input signal by applying digital circuit that processes rick-up coil signal.

Preliminary Experimental Results of Thrust Control for Hybrid Rocket (하이브리드 로켓의 추력 제어 방법에 대한 예비 실험 결과)

  • Lee, Young-Woo;Lee, Min-Jae;Lee, Jong-Lyul;Jung, Sung-Chul;Kim, Hye-Hwan;Huh, Hwan-Il
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.237-240
    • /
    • 2007
  • To control Thrust of propulsion system, we built the 50 N level PE-COx hybrid rocket, and changed the mass flow rate of COx. From the preliminary experiential results, we could see possibility of controlling thrust of the hybrid rocket by controlling mass flow rate of COx.

  • PDF

Design on Platform of Farm Facilities Control and Data Management (FFCD) (농장설비 제어 및 데이터관리 플랫폼 FFCD 설계)

  • Kim, Phyoung-Jung;Hong, Sung-woong;Oh, Young-kyu;Kim, Dal-Joong
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2016.04a
    • /
    • pp.910-912
    • /
    • 2016
  • 우리는 농작물 생산 시 구축되는 각종 전기장치, 릴레이, 컨트롤러, 센서 등을 중앙 집중식으로 관리하는 농장설비 제어 및 데이터관리 플랫폼 (FFCD, Farm Facilities Control and Data Management)을 설계한다. 첫째, PLC 제어를 접목한 설비제어, 둘째, 센서, 컨트롤러 등 다양한 장치의 연결 및 제어, 셋째, 농장 현장의 설비 운영 상황을 실시간으로 모니터링 하고, 넷째, 농산물 생산지표, 품질, 검사 등의 데이터를 축척 할 수 있는 데이터베이스를 구축할 수 있는 기반 플랫폼을 설계한다.

Preliminary Study of Thrust Control for Hybrid Rockets (하이브리드 로켓의 추력제어 기법에 대한 기초연구)

  • Yun, Dong-Ik;Kang, Wan-Kyu;Lee, Young-Woo;Lee, Jong-Lyul;Huh, Hwan-Il
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2008.11a
    • /
    • pp.257-260
    • /
    • 2008
  • In order to control thrust of propulsion system, we built the 50 Newton level PE-GOx hybrid rocket, and changed the mass flow rate of GOx. From the preliminary experiential results, we could see possibility of controlling thrust of hybrid rockets by controlling mass flow rate of GOx.

  • PDF

High Precision Control of Servo Control System Using The Adaptive Fuzzy Controller (적응 퍼지제어기를 이용한 서보 제어 시스템의 정밀제어)

  • 조정환
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.16 no.3
    • /
    • pp.110-115
    • /
    • 2002
  • This paper proposes the adaptive fuzzy control system using the microprocessesor for high precision control of automation systems which exist non-linearities such as saturation, relays, hysteresis, and dead zones. The proposed system which provides the improvement in terms of the control region in transient and adaptive control, first used the frequence-locked mothed driving a system to generate a output voltage proportional to the frequency diffierence of relnence input signal and feedback signal for fast transient response,, and when the error reaches the preset value, used the adaptive fuzzy logic for precision control. The theoretical and experimental studies have been carried out. The presented results from the above investigation show considerable improved performance in the precision control of servo control systems.