• Title/Summary/Keyword: 리브접합부

Search Result 19, Processing Time 0.019 seconds

Equivalent Strut Model for Seismic Design of Steel Moment Connections Reinforced with Ribs (리브로 보강된 철골 모멘트 접합부의 내진설계를 위한 등가 스트럿 모델)

  • 이철호
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.5 no.3
    • /
    • pp.79-85
    • /
    • 2001
  • This paper presents an equivalent strut model for seismic design of steel moment connections reinforced with ribs. It is shown from the finite element analysis results that the force transfer mechanism in the rib connections is completely different from that predicted by the classical beam theory and a clear strut action in the ribs does exist. By treating the rib as a strut, an equivalent strut model that could be used as the basis of a practical design procedure is proposed.

  • PDF

Force Transfer Mechanism of Seismic Steel Moment Connections (리브로 보강된 내진 철골 모멘트 접합부의 웅력전달 메커니즘)

  • Lee, Chol-Ho;Lee, Jae-Kwang;Kwon, Keun-Tae
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2001.04a
    • /
    • pp.269-277
    • /
    • 2001
  • 본 연구에서는 리브로 보강된 내진 철골 모멘트 접합부의 응력전달 메커니즘을 검토하였다. 리브보강 접합부의 응력전달 메커니즘은 고전 휨이론에 의한 예측과 전혀 다르다. 일반적으로 구조 기술자가 리브를 사용할 경우 단면이차모멘트의 증가에 따른 휨응력의 감소효과를 기대하는 것이 보통이다. 그러나 리브는 구조기술자들이 통상 가정하는 휨응력 전달요소라기 보다는 리브 구배 방향의 스트럿 요소로 기능하여 휨응력 외에도 전달응력을 전달한다. 리브를 스트럿 요소로 파악할 때 응력전달 메커니즘을 올바로 파악할 수 있으며 이를 기초로 합리적 설계법의 정립이 가능하다.

  • PDF

Seismic Design of Rib-Reinforced RBS (Reduced Beam Section) Steel Moment Connections Based on Equivalent Strut Model (등가 스트럿 모델에 의한 리브 보강 RBS 철골모멘트접합부의 내진설계)

  • Lee, Cheol Ho
    • Journal of Korean Society of Steel Construction
    • /
    • v.13 no.5
    • /
    • pp.493-502
    • /
    • 2001
  • This paper describes a seismic design procedure for rib-reinforced RBS(Reduced Beam Section) steel moment connections. Engineers often use rib plates to enhance seismic performance of steel moment connections. thinking that the 2nd moment of inertia is increased so that the tensile stress in the beam flange groove weld is reduced However the force transfer mechanism in the rib connections is completely different from that as predicted by the classical beam theory ; a clear diagonal strut action is present in the rib. By treating the rib as a strut the writer has recently proposed an equivalent strut model that could be used as the basis of a practical design procedure. In this paper the proposed equivalent strut model is briefly presented first. A step-by-step design procedure is then recommended based on the proposed model.

  • PDF

Study on the Ultimate Strength of Gusset Plate-Circular Hollow Section(CHS) Joint Stiffened with Rib-plate by End Restraint (단부 구속을 받는 리브 보강 플레이트 원형강관 X형 접합부의 극한내력 도출에 관한 연구)

  • Kim, Woo-Bum;Park, Hyun-Ho
    • Journal of Korean Society of Steel Construction
    • /
    • v.24 no.4
    • /
    • pp.383-398
    • /
    • 2012
  • A finite element analysis study was performed to investigate the behavior and strength of a Plate-Circular Hollow Section joint stiffened with Rib-plate, Since The strength of plate-Circular Section joint is reduced by joint of stress and local plastic deformation which is caused by wall moment, rib plates are attached to the upper and lower Plate-Circular Hollow Section joint for redistribution of stress. The behaviors of joints stiffened with Rib-plate according to shape of rib and reinforcing method, etc are different from those of joints which is not stiffened. However, the criterion of hollow structural section was limited on some parts. Therefore, this study intends to investigate the behavior and structural capacity of Plate-Circular Hollow Section joints stiffened with Rib-plate and compare the Finite element analysis with the Design Equation. Finally, this study proposes the reasonable ultimate strength formula through the comparisons with other design guide.

An Experimental Study of Cyclic Seismic Behavior of Steel Moment Connections Reinforced with Ribs (리브로 보강된 철골 모멘트 접합부의 내진거동에 관한 실험적 연구)

  • Lee, Cheol Ho;Lee, Jae Kwang;Jung, Jong Hyun;Oh, Myeong Ho;Koo, Eun Sook
    • Journal of Korean Society of Steel Construction
    • /
    • v.14 no.4
    • /
    • pp.499-508
    • /
    • 2002
  • A simple design method for rib-reinforced seismic steel moment connections has been recently proposed based on the equivalent strut model. An experimental program was implemented to verify the proposed design method, as well as develop the schemes that will prevent cracking at the rib tip where stress concentration was evident. All specimens designed using the proposed method were able to develop a satisfactory connection plastic rotation of 0.04 radian. In addition to rib reinforcement, slight beam flange trimming pushed the plastic hinging and local buckling of the beam away from the rip tip and effectively reduced cracking potential at the rib tip. Using strain gage readings, the strut action of the rib and resulting reverse shear in the beam web were also experimentally identified.

Behavior and Strength of Rib Stiffened SC Wall-slab Connection (리브 보강된 SC구조 벽-바닥 접합부의 거동 및 내력 평가)

  • Park, Joung Hak
    • Journal of Korean Society of Steel Construction
    • /
    • v.26 no.4
    • /
    • pp.349-359
    • /
    • 2014
  • Until now, wall-slab plate of steel plate concrete has been constructed by joint. But, the shear plate has problems in the workability as well as structural integrity. This study investigates the behavior and strength of rib stiffened SC wall-slab connection. Seven prototype specimens of wall-slab connections were fabricated and tested. the structural safety of the specimens was confirmed through the monotonic loading test. Based on the experimental observations, this study propose the strength formula of the joint was proposed. To enhance the reliability of the proposed strength formula, analytical verification was performed through inelastic finite element analysis. Effect of parameters, such as, load point, friction coefficient, on the joint strength was examined. The proposed formula yields a conservative value for most cases.

The Structural Behavior of CFCT Column to H-Beam Connections With Longitudinal Rib of Column at Joint (종리브로 보강한 콘크리트충전원형강관기둥-H형강보 접합부의 구조적 거동에 관한 연구)

  • Kang, Hyun Sik;Moon, Tae Sup
    • Journal of Korean Society of Steel Construction
    • /
    • v.10 no.2 s.35
    • /
    • pp.291-301
    • /
    • 1998
  • This paper is a study on the structural behavior of CFCT(Concrete-Filled Circular Tubular) column to H-beam connections with longitudinal rib. The important parameters are being longitudinal rib or not. variable column thickness(5.8mm. 9.2mm. 12.0mm. 15.0mm) around the joint between CFCT and H-beam and the width of flange to diameter. Test results are summarized for the strength, initial stiffness, failure mode and energy absorption capacities of each specimen. These are compared with the theoretical results(Yield line theory, numerical analysis). Therefore, the purpose of this paper is to investigate the stiffness and the strength of connections to evaluate the structural behavior of the CFCT column to H-beam connections with longitudinal rib.

  • PDF

An Experimental Study on the Seismic Performance of Shear Connections and Rib Plate H Beam to Column Connections (전단접합 및 리브 플레이트로 보강한 H형 보-기둥 접합부의 내진성능에 관한 실험적 연구)

  • Oh, Kyung Hyun;Seo, Seong Yeon;Kim, Sung Yong;Yang, Young Sung;Kim, Kyu Suk
    • Journal of Korean Society of Steel Construction
    • /
    • v.17 no.5 s.78
    • /
    • pp.569-580
    • /
    • 2005
  • The postbeam joint connection of the existing steel structure moment flexible frame system did not produce sufficient seismic resistance during the earthquakes in Northridge and Kobe, and it sustained brittle fracturing on the joint connection. This study was performed to execute the high-tensile bolt share connection of H-beams web and the full-scale experiment as a parameter of the existing reinforcement of H-flange rib, by making the shape of the existing joint connection. This experiment was performed to determine the extent of the decrease of the number of high-tensile bolts and how to improve workability of the two-phase shear connection of web beam. In addition, this study was performed to enhance the seismic resistant capacity through the enforcement of rib plates. As a result of the experiment of two-phase shear connection of H-beam web and of joint connection to be reinforced by rib plates, the results of this study showed that the initial stiffness, energy-dissipation capacity, and rotational capacity of plasticity was higher than the existing joint connection. As to the rate of increasing the strength and deformation capacity, there were differences between the tension side and compression side because of the position of shear tap. However, as a whole, they have shown excellent seismic resistant capacity. Also, all the test subjects exceeded 4% (rate of delamination), about 0.029 rad (total plastic capacity), and about 130% (maximum strength of joint connection) of fully plastic moment for the original section. Accordingly, this study was considered as it would be available in the design more than the intermediate-level of moment flexible frame.

Seismic Performance of Rib Plate H Beam to Column Connections (리브로 보강된 기둥-보 접합부의 내진성능 평가)

  • Kim, Sung-Yong;Shin, Chang-Hoon
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.6 no.1 s.20
    • /
    • pp.9-16
    • /
    • 2006
  • The moment resisting frame has been well-known as it had very excellent seismic performance, and it has been widely used and constructed in the design of a lot of buildings. However, the moment resisting frame system did not exert the seismic performance during the earthquake in Northridge and Kobe sufficiently, and it produced the crack or brittle fracture on the joint. this study was to ]m tests with the full-scale test subject as parameters of existence of H-beam web high tensile bolt shearing joint and reinforcement of H-flange rib. This researcher was to anticipate the decrease of number of high tensile bolts and the improvement of workability through the double shear joint by the experiment, and improve the seismic performance through the reinforcement of rib plate. In addition, this study was to prevent the brittle fracture by the stress concentration through the non scallop.

An Study on the Stiffened Effect of K-type Tubular Connection (강관 K형 접합부의 보강효과에 관한 연구)

  • Kim, Woo Bum;Lee, Young Jung;Kim, Kap Sun;Chung, Soo Young
    • Journal of Korean Society of Steel Construction
    • /
    • v.13 no.6
    • /
    • pp.609-619
    • /
    • 2001
  • It is almost impossible to evaluate the ultimate strength theoretically, because the behavior of Gusset-Tube connection stiffened with rib-plate is considerably complicate. Therefore in this study a finite element model of gusset-tube connection stiffened with rib-plate was established. The validity of finite element analysis was examined through comparing with previous experimental result and the behavior and strength of the connection was examined. From the parametric study considering lateral force ratio, eccentricity, gusset length based on finite element model, the stiffened effect was estimated and stiffening method was proposed.

  • PDF