• Title/Summary/Keyword: 루프이음의 겹이음 길이

Search Result 2, Processing Time 0.018 seconds

Experimental Study on Connectability of Half-Depth Precast Deck Panels with Loop Joint (루프이음을 갖는 반단면 프리캐스트 바닥판 이음부 성능에 대한 실험적 연구)

  • Chung, Chul Hun;Sung, Yeol Eun;Hyun, Byung Hak;Park, Se Jin
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.4A
    • /
    • pp.581-590
    • /
    • 2008
  • The panels are used as a composite part of the completed deck. They replace the main bottom transverse deck reinforcement and also serve as a form surface for the cast-in-place concrete upper layer that contains the top of deck reinforcement. In this paper, three types of the detail for joints was selected and their structural performance in terms of strength and crack contral was investigated through static tests on composite beams. Form the results, the validity of loop joints for continuity of half-depth precast deck was observed and especially an overlapping length of loop joint and transverse reinforcement were checked. The results suggest that increasing the loop overlapping length increases the flexural strength of half-depth precast deck with loop joints. In terms of crack contral, the loop joint with transverse reinforcement showed better performance.

An Experimental Study on Flexural Behavior of One-Way Concrete Slabs Using Structural Welded Wire-Fabric (구조화 용접철강을 사용한 일방향 슬래브의 휨 거동에 관한 실험적 연구)

  • 허갑수;윤영호;양지수;김석중;정헌수
    • Magazine of the Korea Concrete Institute
    • /
    • v.6 no.2
    • /
    • pp.169-179
    • /
    • 1994
  • Recently the construction of residential buildings faces many difficulties due to the shortage of building materials and works. Simplifying the stage of processing and assembling reinforcing rods and increasing the efficiency of them in reinforced concrete construction can be used to settle the difficulties. In the respect, structural wire-fabric and loop wire-fabric is utilized. The purpose of this study, on condition of being $210kg/cm^2$ concrete strength, is to analyze the structural and flexural properties of one-way concrete slabs by testing with different reinforcing type, tensile steel ratio based with minimum steel ratio, boundary condition and splice length which affect the maximum width of crack and ductility factor. From the test results, the ductility factor is approved that the slabs using deformed bar were much better than that using wire-fabric, and 30D of splice length was appropriate in the slabs as splice length. In the control of the maximum crack width the slabs using wire-fabric and loop wire-fabric were much better than that using deformed bar.