• Title/Summary/Keyword: 렌즈 해석

Search Result 202, Processing Time 0.024 seconds

Optimization of Heating Conditions for Compression Molding of Chalcogenide Glass Lenses Based on Surface Defects (칼코겐유리렌즈 압축성형 시 표면결함을 고려한 가열조건 최적화)

  • Son, Byeong-Rea;Ahn, Jun-Hyung;Lee, Young-Hwan;Hwang, Young-Kug
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.20 no.8
    • /
    • pp.60-66
    • /
    • 2021
  • This study aimed at identifying and optimizing the heating-condition parameters that cause surface defects during the compression molding of chalcogenide glass (GeSbSe) lenses through thermal analysis. We derived the optimal heating conditions for molding chalcogenide glass lenses through thermal analysis and analyzed the surface defects. As a result, we observed a significant reduction in surface defects, which verified the analysis process.

Finite element analysis for acoustic and temperature characteristics of a piezoelectric HIFU transducer at 10 MHz (10 MHz용 압전 HIFU 트랜스듀서의 음향 및 온도 특성에 대한 유한요소해석)

  • Jong-Ho Kim;Il-Gok Hong;Ho-Yong Shin;Hyo-Jun Ahn;Jong-In Im
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.33 no.3
    • /
    • pp.116-123
    • /
    • 2023
  • A high intensity focuses ultrasound (HIFU) is one of the emerging technologies in the biomedical field. The piezoelectric HIFU transducer is a device that utilizes the thermal energy generated by high ultrasound energy. Recently an operating frequency of the HIFU transducer is to expand above a 7 MHz. In this study, the acoustic pressures and temperature distributions in the tissue that generated by the HIFU transducer at 10 MHz were calculated with the finite element method. In addition, the pressure focusing characteristics of the device were analyzed. The geometrical variables are the piezomaterial thickness, lens shape, water height, and film thickness. The results shown that the acoustic pressure increased and saturated gradually when the height/radius (HL/RL) ratio of the lens increased. Moreover, the focal area was gradually decreases with HL/RL ratio of the lens. In case of the optimized HIFU transducer, the maximum pressure and temperature were analyzed about 19 MPa and 65℃ respectively. And the -3 dB focused distances in the axial and lateral direction are around 2.3 mm and 0.23 mm respectively.

Thermal Dispersion Method for a Medical Ultrasonic Phased Array Transducer (의료용 초음파 위상배열 트랜스듀서의 열 분산 방안)

  • Lee, Wonseok;Roh, Yongrae
    • The Journal of the Acoustical Society of Korea
    • /
    • v.34 no.3
    • /
    • pp.210-218
    • /
    • 2015
  • When the driving voltage of an ultrasound transducer is increased to improve the quality of ultrasound images, heat is generated inside the transducer that can cause patient's skin burn and degradation of transducer performance. Hence, in this paper, a method to disperse the heat of the transducer has been studied. The phased array transducer having 3 MHz center frequency and 32 channels was selected for analyses of the thermal dispersion. First, mechanism of the heat generation was investigated in relation to the transducer operation through theoretical analysis, and material damping and sound pressure amplitude were confirmed to be influential on the heat generation. Further, we investigated the effects of the properties of the materials constituting the transducer on the thermal dispersion through finite element analysis. Based on the analysis results, we determined the thermal properties of the constituent materials that could facilitate the thermal dispersion inside the transducer. The determined thermal properties were applied to the finite element model, and the results showed that the maximum temperature at an acoustic lens contacting with a patient was decreased to 51 % of its initial value.

Fatigue Test of Remote CO2 Laser Welded Joints and Its Analysis (원격 CO2 레이저 용접이음에 대한 피로시험과 해석)

  • Chu, Seok-Jae;Zhao, Jun
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.36 no.10
    • /
    • pp.1213-1219
    • /
    • 2012
  • A remote $CO_2$ laser system can rapidly change both the distance and the direction of the laser beam by moving a lens and rotating mirrors. It is then easy to weld complex patterns of weld lines. A conventional spot weld joint specimen and a remote $CO_2$ laser weld joint specimen with complex weld line patterns were prepared and tested both statically and dynamically. The relationships between the fatigue strength, i. e. the maximum cyclic force, and the fatigue life were obtained. The fatigue strength of the tested welded joints at two million cycles was found to be approximately 10% of the static strength. Furthermore, it was observed that the fatigue fracture mode changed with the level of the applied cyclic force. The fatigue crack origins were confirmed as the highest stress points found in the structural analysis. The maximum cyclic stress for different weld patterns converges as the fatigue life approaches two million cycles.

Thermal Design and On-Orbit Thermal Analysis of 6U Nano-Satellite High Resolution Video and Image (HiREV) (6U급 초소형 위성 HiREV(High Resolution Video and Image)의 광학 카메라의 열 설계 및 궤도 열 해석)

  • Han-Seop Shin;Hae-Dong Kim
    • Journal of Space Technology and Applications
    • /
    • v.3 no.3
    • /
    • pp.257-279
    • /
    • 2023
  • Korea Aerospace Research Institute has developed 6U Nano-Satellite high resolution video and image (HiREV) for the purpose of developing core technology for deep space exploration. The 6U HiREV Nano-Satellite has a mission of high-resolution image and video for earth observation, and the thermal pointing error between the lens and the camera module can occur due to the high temperature in camera module on mission mode. The thermal pointing error has a large effect on the resolution, so thermal design should solve it because the HiREV optical camera is developed based on commercial products that are the industrial level. So, when it operates in space, the thermal design is needed, because it has the best performance at room temperature. In this paper, three passive thermal designs were performed for the camera mission payload, and the thermal design was proved to be effective by performing on-orbit thermal analysis.

The Analysis of Multilayered Media Using Ultrasonic Microscopy (초음파 현미경을 이용한 다층구조물의 해석)

  • Ko, Dae-Sik;Jun, Kye-Suk
    • The Journal of the Acoustical Society of Korea
    • /
    • v.9 no.2
    • /
    • pp.5-13
    • /
    • 1990
  • In this paper, 50MHz reflection ultrasonic microscope system with small aperture acoustic lens has been constructed in order to study the defects which lay deep in thick specimens, and acoustic images of multilayered media have been analyzed. Output characteristics of this system for multilayered media have been influenced by acoustic attenuation, aberration in specimen, type of lens and the properties of a defect, and it has been used for image processing of the multilayered I.C. and the bonding layer. In experimental results, it has been shown that small aperture ultrasonic microscope system was powerful tool for inspection of thick specimens such as electronic device, bonding layer, quality of ceramic materials.

  • PDF

Computer Simulation of a Super-Heat Pump System (고효율 수퍼히트펌프에 관한 전산 해석)

  • Kim, H.J.;Jung, D.S.;Kim, C.B.;Ha, K.Y.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.7 no.2
    • /
    • pp.234-248
    • /
    • 1995
  • A super-heat pump system composed of a suction line heat exchanger, low and high stage economizers, and a screw compressor is simulated to examine the energy performance and design options. CFC12, HCFC22, HFC134a, HCFC22/HCFC142b, HFC32/HFC134a, and HFC125/HFC134a are used as working fluids for comparison. The results indicate that the proposed system charged with appropriate mixtures is up to 33.4% more energy efficient than the normal system with CFC12. The performance of the super-heat pump system charged with mixtures was influenced by such factors as the temperature matching, heat source temperature difference, low stage economizer, and high stage economizer. The fluids with a larger liquid specific heat such as HFC134a would have more benefits when a suction line heat exchanger is installed. 40%HCFC22/60%HCFC142b mixture seems to be a good candidate to replace CFC12. On the other hand, 25%HFC32/75% HFC134a would be a good long term candidate to replace HCFC22.

  • PDF

Crosstalk Analysis of Holographic Memory System using Fractal - Space Multiplexing (프랙탈-공간 다중화를 이용한 홀로그래픽 메모리 시스템의 누화해석)

  • 김수길;홍선기
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.1
    • /
    • pp.44-51
    • /
    • 2004
  • Fractal-space multiplexing using a moving window(MW) can multiplex holograms by moving a window left and right. and up and down. But, crosstalk occurs by two neighboring moving windows in the vertical direction of the holographic memory system and limits high-density information recording. Accordingly, we analyzed the crosstalk with the focal length of lens, the distance of MW, and the number of multiplexed hologram to record high-density infromation and presented the optical experimental results of fractal-space multiplexing using volumetric photorefractive crystal and disc type photopolymer.

Cure simulation in LED silicone lense using dynamic reaction kinetics method (승온 반응속도식을 이용한 LED용 실리콘 렌즈의 경화공정해석)

  • Song, Min-Jae;Hong, Seok-Kwan;Park, Jeong-Yeon;Lee, Jeong-Won;Kim, Heung-Kyu
    • Design & Manufacturing
    • /
    • v.8 no.2
    • /
    • pp.46-49
    • /
    • 2014
  • Silicone is recently used for LED chip lense due to its good thermal stability and optical transmittance. In order to predict residual stress which causes optical briefringence and mechanical warpage of silicone, finite element analysis was conducted for curing process during silicone molding. For analysis of curing process, a dynamic cure kinetics model was derived based on the differential scanning calorimetry(DSC) test and applied to the material properties for finite element analysis. Finite element simulation result showed that the slow cure reduced abrupt reaction heat and it was predicted decrease of the residual stress.

  • PDF

Understanding of Protein Adsorption to Contact Lens Hydrogels with Varying Surface Energy (콘택트렌즈용 하이드로젤 계면에너지에 따른 단백질 흡착현상의 이해)

  • Jeon, So-Ha;Noh, Hye-Ran
    • Polymer(Korea)
    • /
    • v.36 no.3
    • /
    • pp.338-343
    • /
    • 2012
  • Interfacial properties of commercially available soft contact lens hydrogels were studied to understand thermodynamic phenomena of protein adsorption. Hydrogel particles ($1{\times}1mm^2$) with varying water wettability were exposed to bovine serum albumin solutions for an hour. The remained albumin solutions were analyzed with Bradford assay method. The amount of protein adsorbed to hydrogels increased with protein solution concentrations following Langmuir isotherm. The partition coefficient ($P$) and Gibbs free energy cost of dehydrating the surface region by protein displacement upon adsorption increased with increasing hydrophilicity of contact lens. Understanding of physical chemistry in protein adsorption to contact lens materials enabled elucidating relationships between surface energy and albumin adsorption capacity.