• Title/Summary/Keyword: 렌즈 굴절력

Search Result 88, Processing Time 0.019 seconds

Optical Design of an Inspection Apparatus for Dynamic Visual Acuity (동체시력 검사기의 광학계 설계)

  • Lee, Dong-Hee;Kim, Hye-Dong
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.9 no.2
    • /
    • pp.473-480
    • /
    • 2004
  • Recently, they are interested in the relation between night's vehicle accidents of drivers and the dynamic visual acuity at home and aboard. So, in this research, we tried to design an optical system of the inspection equipment to measure the dynamic visual acuity. A optotype standard did to Landolt's ring with 45mm of diameter and 9mm of gap to maintain the visual acuity of 1.0 in the 30m distance. An optical structure of the inspection equipment was composed of the sequence of an observer, a plus refraction lens system, a minus refraction lens system, and an optotype that was arranged to have characteristics that the size of the first virtual image of the optotype made by the minus refraction lens system grows bigger gradually according to the optotype movement to near distance from far distance, and also the first virtual image moves to the principle plane from the focal point of the plus refraction lens system as the size of the first virtual image arranged to the inside of focal distance of plus refraction lens system grows bigger gradually. As doing these processes, we completed the optical system of which characteristic is that the position of the final second virtual image moves to 3m from 50m as the size of the second virtual image made by the plus refraction lens system maintains to be regular.

  • PDF

A Comparative Study on Prescription Lenses Standards (주문형 렌즈의 규격 비교 연구)

  • Moon, Byeong-Yeon;Paik, Sun-Mok;Yu, Dong-Sik
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.14 no.1
    • /
    • pp.17-21
    • /
    • 2009
  • Purpose: To evaluate and analyze the quality of Korean prescription lenses according to international standards. Methods: We measured the refractive power, the thickness at optical center and the transmittance, and then made a comparative analysis them with foreign brand products according to international standards. Results: Most of Korean products had good qualities on the refractive power and transmittance, even if there was out of tolerance in a case of korean products. Conclusions: To ensure a higher preference of Korean products in the home and abroad marketplace, a high-powered quality control and marketing strategy are necessary to domestic lens manufacturers.

  • PDF

Front Radius of Spherical Spectacle Lens in the Cosmetic and the Optical Corsiderations (구면 안경렌즈의 미용적 측면에서의 곡률반경과 광학적 고찰)

  • Jung, Boo-Young;Joo, Kyung-Bok
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.10 no.4
    • /
    • pp.405-410
    • /
    • 2005
  • In this paper, the front radiuses of curvature of spherical spectacle lenses in the cosmetic and optical point of view are investigated and are calculated using Zinken-Sommer condition. The optical power of all spherical spectacle lens shows good quality at the test using autometic lensmeter. However the front radiuses of curvature of spherical spectacle lenses are quite different depending on the lens companies. The front radius of curvature of those lenses is larger than that calculated using Zinken-Sommer condition. We know that the front radius of curvature of commercial spectacle lens is emphasized more cosmetic aspect than optical point of view.

  • PDF

Diameter of the retinal blur circle in a artificial hypermetropia (인워적 원시에 따른 망막에서 착란원 크기)

  • Choi, Woon Sang;Kim, Yoon-Kyung;Oh, Heung Geun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.10 no.2
    • /
    • pp.145-149
    • /
    • 2005
  • In a artificial hypermetropia with the accommodative response, we investigated a diameter of blur circle as a function of test lens refractive power. In a schematic eye model of the hypermetropia, the second focal length along to accommodated power of the crystal lens are calculated as a function of test lens power and, also distance between the retina and exit pupil are calculated as a function of accommodated power. As these results are compared, the size of blur circle on the retina are obtained.

  • PDF

The Effect of Refractive and Corneal Recovery after Discontinuation of Orthokeratology Contact Lenses in Children (각막굴절교정렌즈 어린이 착용자에서 착용 중지 후 굴절력과 각막형상 복귀에 관한 연구)

  • Mun, Mi-Young;Lee, Koon-Ja;Lee, Ji-Young
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.14 no.3
    • /
    • pp.7-15
    • /
    • 2009
  • Purpose: To investigate the corneal recovery after discontinuing orthokeratology (OK) lenses wear in children for long-term period. Methods: Among the OK lens wearers who wear over 8 months and showed successful refractive correction, 25 subjects were selected who want to discontinue the OK lenses. Uncorrected visual acuity, refractive correction, corneal curvature (Sim K), central corneal thickness and corneal eccentricity were measured during the OK lens wearing period and after discontinuation for 1 month. Results: Uncorrected visual acuity and corneal shape had remodeled significantly during the OK lens wear and recovered significantly during the first week of discontinuation. Uncorrected visual acuity and refractive correction had achieved full recovery 2 weeks after discontinuation of lens wear and were highly correlated with the changes in corneal thickness. But corneal shape recovered slowly, eccentricity had recovered fully after 1 month and corneal curvature and central thickness had not been achieved full recovery until 1 month after discontinuation. Conclusions: Recovery of after longterm use of OK lens is rapid for refractive change, but slow for corneal curvature and central thickness that to refit the contact lenses, practitioners need patience.

  • PDF

The Study on Change of Refractive error and Addition in Progressive Eyeglasses Lens Wearers (누진렌즈안경 착용자의 가입도와 굴절이상 변화에 대한 연구)

  • Joo, Seok-Hee;Shim, Moon-Sik;Shim, Jun-Beom
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.4
    • /
    • pp.399-404
    • /
    • 2013
  • Purpose: This study was to analyse the changes of refractive error and addition in progressive eyeglasses lens wearers. Methods: Data of 244 subjects who have been prescribed progressive eyeglasses lenses were used for analysis. The range of age was between 43~69 old years and they visited the optical shop in Gwangju metropolitan city from 2003 to 2013. According to the refractive state and age, The changes of refractive error and addition was analysed respectively. Results: The changes of distance refractive power by refractive error was showed +0.10 D in emmetropia, +0.07 D in myopia, +0.23 D in hyperopia (p=0.000). The change of addition was showed +0.22 D in emmetropia, +0.29 D in myopia, +0.17 D in hyperopia (p=0.000). The changes of distance power and addition by age was +0.08 D distance refractive power, +0.30 D addition in the group of 40~49 old years, +0.17 D distance refractive power, +0.20 D addition in the group of 50~59 old years and +0.15 D distance refractive power, +0.14 D addition in the group of 60~69 old years (p=0.046, p=0.006). Conclusions: The changes of refractive error and addition of progressive eyeglasses lens wearers in all refractive state and age were gradual increase in the direction (+) diopter.

Measurement of the Power of a Cylindrical Lens with the Magnification Ellipse Fitting Method (배율 타원 근사법을 실린더 렌즈의 굴절력 측정)

  • Ko, Woo-Seok;Ye, Sang-Heon;Kwak, Yoon-Keun;Kim, Soo-Hyun
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.25 no.2
    • /
    • pp.43-48
    • /
    • 2008
  • This paper proposes a new method for measuring the power of spherical and cylindrical lens with 6 points light source, which is composed of a LED and six holes, and magnification ellipse fitting algorithm. Each measured diagonal length of 6 points light source is determined by the target lens power. After finding the center position of each light point with threshold method, 3 axis-diagonal lengths were calculated. The long axis and short axis power of cylindrical lens can be calculated by using magnification ellipse fitting algorithm with the magnification relationships between the initial diagonal lengths and the measured diagonal lengths changed by lens power.

Study of Masking Effect of Soft Contact Lenses on Cornea after Refractive Surgery (각막굴절교정 수술 안에 대한 소프트콘택트렌즈 착용 시 Masking 효과)

  • Moon, Ye-Rim;Park, Hyung-Min;Chu, Byoung-Sun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.21 no.2
    • /
    • pp.91-98
    • /
    • 2016
  • Purpose: This study investigated the masking effect of the hydrogel lens and silicone hydrogel lens on the cornea with refractive surgery and without surgery. Methods: 24 university students (means age: $23.48{\pm}2.89years$) without refractive surgery (12, control group) and with refractive surgery (LASIK: 8, LASEK: 4, experimental group) participated in the study. Mean refractive errors of right eyes were -2.73 D for control group and -0.24 D for experimental group. The differences in the refractive power and corneal topography map between pre- and post-wearing the -3.00 D lenses were compared, and 2 kinds of hydrogel contact lenses (0.89 Mpa, 0.49 Mpa) and 2 kinds of silicone hydrogel lenses (1.5 Mpa, 0.8 Mpa) were used for -3.00 D lenses. NVision-K5001 (Shin nippon, Japan) was used to measure the refractive power and Keratograph 5M (Oculus, Germany) to measure the corneal topography map change. Results: Variations in the refractive power increased to the plus direction in the experimental group after wearing soft contact lenses. The corneal topography map showed significant changes on the both groups after wearing soft contact lenses (p<0.05). However there were no significant differences in the refractive power and corneal topography map variations by lens materials. Conclusions: Wearing soft contact lenses showed corneal topography map changes. Especially wearing soft contact lenses on the flat cornea after corneal refractive surgery showed greater corneal power changes. Therefore, it should pay attention to refractive change in case of prescribing soft contact lenses to patients with corneal refractive surgery.

Research of Difference between the Refractive Powers by Autorefractometer and the Prescription using Phoropter (자동 굴절력계의 굴절력값과 포롭터를 이용한 처방값의 차이에 관한 연구)

  • Lee, Ju-Whan;Lee, Koo-Seok;Hong, Hyung-Ki
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.2
    • /
    • pp.231-237
    • /
    • 2014
  • Purpose: This study is research of the conditions which causes difference between the refractive power of the measurement of autorefractometer and the prescription using phoropter. Methods: Autorefractometer (SR-7000) and phoroptor (AV-9000) were used to measure 60 eyes of 30 participants who had no eye diseases and wore the corrective lens due to Ametropia. To prevent the dependence of the prescription value of the refractive power on the testers, two testers measured the refractive power of the eyes of the participants at the same measuring conditions. Results: Statistically, the prescribed values of the refractive power by two testers were not significantly different. Most of the prescribed values of the refractive power were smaller than the refractive power by autorefractometer In case of myopic eyes, the difference between refractive powers by the measurement of autorefractometer and the prescription using phoropter showed the trend of increase as the spherical refractive power became larger. The result was analyzed by the range of the different cylindrical refractive power for the myopic astigmatic eyes. In this case, the difference between refractive powers showed the trend of decrease as the cylindrical refractive power became larger. Conclusions: No difference between the prescribed value by two testers was observed. In case of myopic or myopic astigmatic eyes, the difference between refractive powers by autorefractometer and the prescription were measured to be approximately proportional to the refractive powers of ametropic eyes. As the this difference become larger for the participant who needs the lens of larger refractive power, additional caution is needed in the prescription of the refractive power of the corrective lens.

The Effect of Long-Term Orthokeratology in Different Age Groups (장기간 굴절교정렌즈 착용자에서 연령군 별 굴절교정효과 비교)

  • Mun, Mi-Young;Lee, Koon-Ja
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.13 no.4
    • /
    • pp.65-73
    • /
    • 2008
  • Purpose: The purpose of this study is to investigate the effect of age in the response to long-term overnight orthokeratology (OK) lens wearing. Methods: Among volunteers, ninety-five healthy subjects who had no eye diseases and could wear OK contact lens at least for 8 hours every day were divided into three groups children, youngsters and young adults. Unaided logMAR visual acuity, refractive error, apical corneal radius, corneal asphericity and central corneal thickness were measured with different period; before and after one day, one week, two weeks, one month, three months and six months of OK lens wear. Paired student t-test, ANOVA analysis and Pearson correlation were used with a critical p value of 0.05 for statistical analysis. Results: All groups showed statistically significant (p<0.001) improvement in unaided visual acuity, a trend for flattening in the apical corneal radius, decrease in central corneal thickness and less prolate after OK lens wear. The child group showed significantly rapid change (p<0.001) in visual acuity, and apical corneal radius showed that they reached the targeted refractive change earlier compared with youngster and adult groups. The visual effect of OK lens was significantly related with the change in central corneal thickness after long-term OK lens wear, especially in child and youngster group, and central corneal thickness were highly correlated with the targeted refractive change. Conclusions: Visual acuity change is statistically correlated with the central corneal thickness change, which is highly correlated with targeted refractive change in the long-term orthokeratology and younger lens wearers showed a rapid response to OK lens wear, suggesting a reduced epithelial response with increasing age. The results found this study extends our understanding and development in the long-term orthokeratology.