• Title/Summary/Keyword: 렌즈두께

Search Result 124, Processing Time 0.021 seconds

Stable lateral-shearing interferometer for in-line inspection of aspheric pick-up lenses (생산 라인에서의 광 Pick-up용 비구면 대물 렌즈 측정을 위한 안정된 층밀리기 간섭계)

  • 조우종;김병창;김승우
    • Korean Journal of Optics and Photonics
    • /
    • v.8 no.3
    • /
    • pp.189-193
    • /
    • 1997
  • Aspheric pick-up lenses are increasingly used in consumer products such as computer and multimedia, as their mass production has become possible owing to the injection molding process. However still much work needs to be done for more effective manufacture of aspheric lenses, one area of which is the in-line inspection of produced lenses. In this paper, we present a lateral-shearing interferometer that has specially been designed to have a high immunity to external vibration and atmospheric disturbance. The interferometer comprises four prisms. They are directly attached to each other using an immersion oil so that relative sliding motions between the prisms are allowed. Their relative displacement can readily generate necessary lateral-shearing and phase-shifting to determine the wavefront of the beam collimated by the lens under inspection. A special phase-measuring algorithm of arbitrary-bucket is adopted to compensate the phase-shifting error caused by the thickness reduction in the immersion oil. Zernike polynomial fitting has done for determinating quantitative aberration of aspheric pick-up lenses. The interferometer built in this work is robust to external mechanical vibration and atmospheric disturbance so that experimental results show that it has a repeatability of less than λ/100.

  • PDF

The momentary movement of soft contact lens by blinking : The change of movement depending on wearing time (손목에 의한 소프트콘택트렌즈의 순간적인 움직임 : 착용시간의 증가에 따른 움직임의 변화)

  • Park, Sang-Il;Lee, Youn Jin;Lee, Heum-Sook;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.12 no.1
    • /
    • pp.1-7
    • /
    • 2007
  • To investigate the momentary movement pattern of soft contact lens(SCL) depending on wearing time, eight types of soft contact lenses were worn by 10 normal subjects and the momentary movements of SCLs were estimated using by high speed camera(FASTCAM ultima 1024). When the momentary movements of SCLs in the cornea between blinkings were compared after 15 min wearing, the vertical movements of all eight SCLs were about 2 times larger than the horizontal movement but the extent of these movement difference was a function of kinds of SCLs. The momentary moving distance of SCL varied from the kinds of SCLs, which A and B lens, daily wear lens, moved significantly larger distance compared with other SCLs. The momentary movements between blinkings decreased significantly after 8hr wear of SCLs. The extents were different when SCLs were compared with each other, which the reduction range of horizontal and vertical movement was 24.6~60.0% and 20.4~94.3%, respectively. The A, B and C lenses which had relatively higher water content showed the larger movement reduction after SCL wear. This results suggest that wearing SCL for some hours decreases the movement of SCl, which can induce the change of tear flow.

  • PDF

A Comparative Study on Ophthalmic Lenses Standards (시력 보정용 안경렌즈의 규격 비교 연구)

  • Kwak, Ho-Won;Yu, Dong-Sik;Moon, Byeong-Yeon
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.10 no.3
    • /
    • pp.221-228
    • /
    • 2005
  • In order to analyze the difference of lenses production, we measured the refractive power and the thickness of their optical centers using ophthalmic lenses which were distributed at home country and abroad. The home products were manufactured to be next to foreign goods, but there were several cases to exceed acceptable limits and we need to reduce the deviation from measuring values in the same lenses. To get a beat on advanced countries, rearing technical expert, hard quality test and process control and standardization of lenses are essential to home lens industrials.

  • PDF

광섬유/필터 자동 광축 정렬시스템을 이용한 초소형 광통신용 1$\times$1 OADM(Optical Add/Drop Multiplexer) 모듈 제작

  • 김성곤;박한수;서영호;최두선;황경현
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.121-121
    • /
    • 2004
  • 최근 급속히 성장하고 있는 광통신산업의 발전에 있어서 주목할 만한 경향 중에 하나는 제품의 소형화 및 집적화라 할 것이다. 마이크로 광모듈 접속/조립 시스템은 광모듈을 소형화하고 고기능성 광통신 부품의 개발에 있어 가장 필요한 장비이다. 이에 본 연구에서는 초소형 광모듈 접속/조립 시스템을 개발하기 위하여 두께가 약 30 $\mu\textrm{m}$인 박막형 필터와 렌즈일체형 파이버를 접속/조립할 수 있는 시스템을 개발 및 초소형 광통신용 1$\times$1 OADM(Optical Add/Drop Module) 모듈을 제작하였다.(중략)

  • PDF

x$^{(3)}$ Measurement through Self-focusing with Non-gaussian Beam (비 Gaussian 빛에 의한 자체집광을 이용한 x$^{(3)}$측정)

  • 이범구
    • Korean Journal of Optics and Photonics
    • /
    • v.4 no.4
    • /
    • pp.428-433
    • /
    • 1993
  • The second harmonic of Q-switched Nd:YAG laser beam with gaussian mode is cut off by pinhole of a certain radius and its central portion passed through pinhole is focused by converging lens. It is confirmed that the shape of this beam in focal region is central symmetric but non-gaussian. Change of transmittance due to self-focusing is investigated by scanning (z-scan) $CS_2$ of 1 mm thickness in the focal region. It is found that the observed results can be consistently explained by Fresnel theory within 1.5% accuracy and efficiency of self-focusing depends on spatial shape of incident beam.

  • PDF

The Clinical Study on the Visual Acuity and Cornea of ez-NANOsence II RGP Contact Lens (ez NANOsence II RGP 콘택트렌즈의 시력과 각막에 미치는 임상적 연구)

  • Kim, Douk-Hoon;Bae, Han-Young;Han, Mung-Gyo
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.12 no.4
    • /
    • pp.55-69
    • /
    • 2007
  • The purpose of this study was to perform a clinical test using ez NANOsence II RGP contact lenses for the effects of visual acuity and cornea on subjects with abnormal refraction status. One hundred twenty one adults (twenty nine males, ninety two females, range = 17 to 43, mean = 22.86) were recorded. The subject's history including, the symptoms from previous lens wear, were studied. The subjects were observed, both pre and post lens wear, for any symptoms and signs of change of the eye. The Visual acuity and the binocular status were tested at the far distance using the contact lens. The refraction test was performed on the naked eye using the objective method (Topcon KR-8100, Japan). The Stereopsis test was performed at the near distance after contact lens wear by the Titmus fly (Stereo Optical Co., U.S.A) and TNO (TECH, The netherlands). The contrast sensitivity diagnosis was performed at 1m distance after contact lens wear by the contrast sensitivity chart (pelli-Robertson, USA). The corneal topography was analyzed on the naked eye after lens wear by ORB scan (Bausch Lomb, U.S.A.). The ultra structure of surface on the contact lens was observed using SEM (JMS-5800, Japan). The chemical component's of the contact lens was analyzed by EDS program. The results of this study were as follows: 1. The longer of contact lens wear period, The subjects have acquired the most improved visual function. 2. Subjects had experienced few side effects wearing the contact lenses. 3. The lenses were easy to use by the subjects. 4. The longer of contact lens wear period, the power of cornea had more decrease. but the base curve of cornea had more increase and corneal astigmatism was decrease (p<0.01). Also, the thickness of corneal center was few decrease. 5. Longer periods of using the contact lens showed stereopsis and contrast sensitivity at more normal values. 6 The corneal topographical after lens wear showed most subjects with similar morphology for different wear periods. 7. The surface ultrastructure of the new and used contact lens was the similar fine shape. 8. The chemical component's of in the new and used contact appeared to have similar results. In conclusion, this study showed that the surface ultrastructure and chemical component's of the new and used contact lens are similar. In addition, the subjects had improved the quality of vision and few experienced any side effects during long periods of contact lens wear. Also they have decrease of corneal astigmatism during the long period of lens wear. Our test has showed that the chemical composition and fine structure of contact lens have related to the visual function on contact lens wearer. In this paper, we suggested that ez NANOsence II RGP contact lenses had a moderate effect for correcting vision of abnormal refraction eye.

  • PDF

The Effects of Ultrasonic Cleaner for Eye Glasses on Protein Deposits and Parameters in Soft Contact Lens (안경용 초음파세척기에 의한 소프트콘택트렌즈의 단백질 침전물 세척효과)

  • Ju, Eun-Hee;Lee, Koon-Ja;Leem, Hyun-Sung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.15 no.3
    • /
    • pp.227-234
    • /
    • 2010
  • Purpose: The cleaning effect of protein deposit and the change of contact lens parameters by ultrasonic cleaner for eye glasses on the soft contact lenses were investigated. Methods: Etafilcon A contact lenses contaminated with protein, was ultrasonicated by ultrasonic cleaner for eye glasses and for the control group, spoiled contact lenses were cleaned by multi-purpose solution. The remaining protein deposits on the contact lenses were determined after extraction and the changes of overall diameter, base curve, center thickness power, and water contents on contact lenses were measured and surfaces of contact lenses were observed by scanning electron microscope. Results: The cleaning efficacies of multi-purpose solution on protein deposited etafilcon A contact lenses were 6.08%, and 23.73~33.92% in the group of ultrasonic cleaner for eye glasses with multi-purpose solution and 0~12.99% in the group of ultrasonic clear for contact lens with multipurpose solution depending on the treatment time. The changes of parameters and surface on contact lenses by ultrasonication were not observed. Conclusions: Ultrasonic cleaner for eye glasses can be used to eliminate protein deposits for the diagnostic soft contact lens in the office since it was effective to eliminate protein deposits and not caused change of parameters on soft contact lenses.

Optical Design of Gradient-Index Objective for Optical Pickup (광 Pickup 용 Gradient-Index 대물렌즈 설계)

  • Park, In-Kyu;Lee, Jong-Ung
    • Korean Journal of Optics and Photonics
    • /
    • v.18 no.4
    • /
    • pp.256-263
    • /
    • 2007
  • High NA objective design by using SELFOC materials was studied, and two kinds of objective for optical pick-up were designed. The SELFOC materials have radial gradient index distribution, and it gives additional degree of freedom in optical design. Therefore, we expect that optical design of high NA objective without aspheric surface will be possible. In this study, the variation of ms spot diameter was investigated as a function of quadratic constant and refractive index on axis for various combinations of axial thickness and entrance pupil diameter. For the survey, Code V was used for optimization and evaluation of the objective lenses. The result suggested that larger quadratic constant and higher refractive index on axis could give us better imaging performance for all combinations of axial thickness and pupil diameter. Based on the survey, we designed high NA objectives for DVR. There were two kinds of design solution consisting two spherical SELFOC lenses. The solution I had positive-positive lens configuration with short over-all-length, but it had poor off-axial performance compared with the solution II. The solution II had negative-positive lens configuration with good off-axial imaging performance. But the solution II had some disadvantages, long over-all-length and large diameter of the second lens.

A Study on the Quality Improvement of Red Dot Sight for Grenade Launcher by Parallax Reduction (고속유탄기관총용 조준경의 시차 개선을 통한 조준경 품질 향상에 관한 연구)

  • Kim, Ji-Hoon;Jeung, Bo-Sun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.11
    • /
    • pp.130-135
    • /
    • 2019
  • This study performed the quality improvement of a red dot sight for a 40 mm grenade launcher through parallax reduction. The red dot sight cited in this study is currently in mass production for military use as a non-weapon system. While the red dot sight's parallax currently meets requirements, slightly greater error was observed on the outside of effective optical area of the reflection lens compared to other sights. Parallax is easily affected by eye movement, which can result in aiming error. To improve the red dot sight's quality, this study analyzed why parallax is observed in the effective optical area of the reflection lens and how to reduce it. As a result, the red dot sight demonstrated lower parallax error using the new optical system design with an increased reflection lens thickness and modified components configuration related to the reflection lens assembly. Parallax was calculated and simulated by using a particular program to verify that it decreased. This improvement for the 40 mm. grenade launcher red dot sight more than satisfies requirements, offers advanced capabilities for users, and as a result, successful operation carryout.

The Influence of the Variation of Conic Coefficient of the Front Surface on RMS Spot Diameter (전면의 conic 계수 변화가 착락원 크기에 미치는 영향)

  • Park, Seong-Jong;Ju, Seok-Hee;Sim, Sang-Hyun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.8 no.2
    • /
    • pp.77-83
    • /
    • 2003
  • To investigate the influence of the variation of conic coefficient of the front surface on the RMS SD(Root Mean Square Spot Diameter) in a back focal plane, we use programs which are Cove V and LOSA 2.0. We consider a spectacle lens with back vertex power of -4.00D, diameter of 70 mm, the front surface powers which are 2.00D, 4.00D, 6.00D, and 8.00D, and the indices which are $n_d$=1.498, 1.523, 1.586, and 1.660, respectively. The RMS SD in the back focal plane and the thickness of an aspherical tens having the optimized conic constant are smaller than those of a spherical lens. The RMS SD in the back focal plane decreases as the front surface power decreases. From these results, we determine the optimized conic constant to improve the optical image quality and decrease RMS SD in the back focal plane.

  • PDF