• Title/Summary/Keyword: 레이져 유도 플라즈마 분광법

Search Result 4, Processing Time 0.017 seconds

Analysis of Heavy Metal Concentration in Construction By-Products using Laser-Induced Breakdown Spectroscopy and Membrane Techniques (레이져 유도 플라즈마 분광법(LIBS)과 멤브레인을 활용한 건설용 부산물 내 중금속 분석에 관한 연구)

  • Park, Won-Jun
    • Journal of the Korea Institute of Building Construction
    • /
    • v.23 no.2
    • /
    • pp.113-121
    • /
    • 2023
  • In this study, the applicability and reproducibility of laser induced breakdown spectroscopy(LIBS) for heavy metal analysis in clinker and 5 types of by-products(crushed stone sludge, blast furnace slag, steel slag, waste concrete sludge, bottom ash) were experimentally reviewed. As a result of ICP-MS, XRF, and LIBS analysis of the six samples, the difference between ICP and XRF was confirmed in the quantitative analysis, but the LIBS analysis showed a difference by element from the standard analysis, and only qualitative analysis of the sample was possible. LIBS analysis wavelength was set for three types of heavy metals(Cd - 214.44nm, Pb - 405.78nm, Hg - 253.65nm). As a result of laser irradiation on the surface of the membrane impregnated with a solution of each concentration(1~1000ppm) and dried, the correlation between the spectral intensity and the concentration was confirmed.

Analysis of Chloride Penetration in Mortar Sections using Laser Induced Breakdown Spectroscopy (LIBS를 활용한 모르타르 단면 염화물 침투 분석)

  • Park, Won-Jun
    • Journal of the Korea Institute of Building Construction
    • /
    • v.21 no.6
    • /
    • pp.583-591
    • /
    • 2021
  • In this study, the applicability and reproducibility of LIBS in the analysis of chloride penetration in the mortar section were investigated. Standard analysis (IC, potentiometric titration) and LIBS analysis were simultaneously performed on the accelerated and immersed mortar by chloride concentration. Through LIBS analysis after making an eluate at the same depth for each concentration, the signal intensity of chloride ions was confirmed according to the depth and concentration at the wavelength of 837.59 nm, and a correlation between the LIBS signal intensity and the chloride concentration was confirmed. Although it is an aqueous solution-based LIBS analysis, the applicability and reproducibility of LIBS were confirmed not only for the incorporation of chloride but also for the amount of permeated chloride.

Analysis of Chloride Content in Aqueous Solution and Mortar using Laser Induced Breakdown Spectroscopy (LIBS를 활용한 수용액과 모르타르 내 염화물량 분석)

  • Ryu, Hwa-Sung;Park, Won-Jun
    • Journal of the Korea Institute of Building Construction
    • /
    • v.21 no.3
    • /
    • pp.189-194
    • /
    • 2021
  • LIBS has been attracting attention as an analytical method capable of real-time measurement without sample preparation. In this study, a Lab. scale LIBS device was fabricated to examine the applicability and reproducibility of LIBS in the analysis of chloride contents in mortar. The existing analysis method and LIBS analysis were performed simultaneously on the mortar test specimen with the chloride content adjusted. Compared to the chloride content condition of the mortar, the XRF and Potentiometric Titration results also showed a similar trend. As a result of LIBS analysis, chlorine ions were detected at a wavelength of 837.59 nm according to the chloride content condition. In order to improve the precision in various concentration ranges, the LIBS signal amplification of about 50 times through the electric field enhancement was implemented. Through the verification of the aqueous solution-based reproducibility, a high correlation between the LIBS signal strength and the Cl concentration was confirmed, and the possibility of applying LIBS to the durability diagnosis of concrete damage by chloride was confirmed.

A Comparative Study of Sulfate and Chloride Intrusion in Mortar Sections: An Approach Using Laser Induced Breakdown Spectroscopy and Ion Exchange Membrane (LIBS와 이온교환막을 활용한 모르타르 단면 침투 황산염과 염화물 분석)

  • Park, Won-Jun
    • Journal of the Korea Institute of Building Construction
    • /
    • v.23 no.3
    • /
    • pp.221-229
    • /
    • 2023
  • This research aimed to conduct an empirical assessment of the penetration of chloride and sulfate ions into mortar sections using an anion exchange membrane(AEM) and laser-induced breakdown spectroscopy(LIBS). The study involved a simultaneous ion chromatography(IC) analysis and LIBS analysis performed on mortars immersed in varying concentrations of chloride and sulfate. The findings revealed that at the wavelengths specific to Chloride(837.59nm) and Sulfur(921.30nm), the LIBS intensity achieved using AEM surpassed that obtained with a paper substrate at equivalent penetration concentrations. A robust correlation was confirmed between LIBS intensity and chloride ion concentration. Furthermore, when juxtaposed with IC analysis concentration outcomes at identical depths, the AEM displayed a higher intensity. The research noted an enhancement in LIBS intensity and a diminution in errors within the low-concentration section when deploying AEM. However, for the Sulfur wavelength of 921.3nm, there remains a need to augment the sensitivity of the LIBS signal within the low-concentration section in future studies. The findings underscore the potential of employing AEM and LIBS for precise analysis of chloride and sulfate ion penetration into mortar sections. This strategy can aid in bolstering assessment precision and mitigating errors, particularly in regions with low concentrations. It is recommended to further research and develop methods to amplify the sensitivity of the LIBS signal for sulfur detection in low-concentration sections. In sum, the study accentuates the significance of employing advanced techniques like AEM and LIBS for efficacious and precise analysis in the domain of mortar section assessment.