• Title/Summary/Keyword: 레이저 유도

Search Result 565, Processing Time 0.029 seconds

Effect of Non-Perforated Breathable Films on the Quality and Shelf Life of Paprika during MA Storage in Simulated Long Distance Export Condition (비천공 Breathable필름이 장거리 모의 수출 조건에서 파프리카의 MA 저장중 품질과 저장수명에 미치는 영향)

  • Choi, In-Lee;Yoo, Tae-Jong;Kim, Il-Seop;Lee, Yong-Beom;Kang, Ho-Min
    • Journal of Bio-Environment Control
    • /
    • v.20 no.2
    • /
    • pp.150-155
    • /
    • 2011
  • The aim of this study was investigated long distance export condition of paprika from Korea to Canada, and evaluated the effect of non-perforated breathable films on the storability of paprika during MA storage in the simulated long distance export condition. The long distance export condition of paprika from Korea to Canada was $7{\pm}1^{\circ}C$ and RH 90% during shipping for 20 days, and then the temperature of that was increased to $13^{\circ}C$ for 3 hours during transferring from refrigerated container to storage room in Canada, and decreased $3{\sim}4^{\circ}C$ for 3 days before distributing to local markets. The temperature and relative humidity of local markets was $16^{\circ}C$ and 60%, respectively. The packing material treatments were non-packing, as control, perforated film (6 mm diameter hole, $18holes/m^2$), and 3 kind of laser treated non-perforated films (oxygen transmission rate was 5,000, 20,000 and 100,000 $cc/m^2{\cdot}day{\cdot}atm$). Under the simulated long distance export condition; $7^{\circ}C$ and RH 90% for 15 days and then $20^{\circ}C$ and RH 55% for 7 days, the fresh weight loss of paprika was less than 1% in 3 kind of laser treated non-perforated film treatments but was more than 4% in control and perforated film treatment that showed severe deterioration of visual quality after 20 days of storage. The atmosphere of paprika packages was changed 5% oxygen and 15% carbon dioxide in 5,000 $cc/m^2{\cdot}day{\cdot}atm$ treatment, and 16% oxygen and 4~5% carbon dioxide in 20,000 $cc/m^2{\cdot}day{\cdot}atm$ treatment during room temperature storage after cold storage for 15 days. A carbon dioxide concentration of these 2 treatments was exceeded the optimal MA and CA condition. There was no significant difference in ethylene concentration among 3 kind of laser treated non-perforated film treatments. A paprika packed with 100,000 $cc/m^2{\cdot}day{\cdot}atm$ non-perforated film showed the highest visual quality under the simulated long distance export condition. However, the firmness and soluble solids did not show any significant difference among 3 kind of laser treated non-perforated film treatments. Therefore, we may suggest that 100,000 $cc/m^2{\cdot}day{\cdot}atm$ laser treated non-perforated film was the proper film for MAP of paprika under long distance export condition that was $7{\pm}1^{\circ}C$ and RH 90% for 15 days, and then $20^{\circ}C$ and RH 55% for 7 days.

Study on the screening method for determination of heavy metals in cellular phone for the restrictions on the use of certain hazardous substances (RoHS) (유해물질 규제법(RoHS)에 따른 휴대폰 내의 중금속 함유량 측정을 위한 스크리닝법 연구)

  • Kim, Y.H.;Lee, J.S.;Lim, H.B.
    • Analytical Science and Technology
    • /
    • v.23 no.1
    • /
    • pp.1-14
    • /
    • 2010
  • It is of importance that all countries in worldwide, including EU and China, have adopted the Restrictions on the use of certain Hazardous Substances (RoHS) for all electronics. IEC62321 document, which was published by the International Electronics Committee (IEC) can have conflicts with the standards in the market. On the contrary Publicly Accessible Specification (PAS) for sampling published by IEC TC111 can be adopted for complementary application. In this work, we tried to find a route to disassemble and disjoint cellular phone sample, based on PAS and compare the screening methods available in the market. For this work, the cellular phone produced in 2001, before the regulation was born, was chosen for better detection. Although X-ray Fluorescence (XRF) showed excellent performance for screening, fast and easy handling, it can give information on the surface, not the bulk, and have some limitations due to significant matrix interference and lack of variety of standards for quantification. It means that screening with XRF sometimes requires supplementary tool. There are several techniques available in the market of analytical instruments. Laser ablation (LA) ICP-MS, energy dispersive (ED) XRF and scanning electron microscope (SEM)-energy dispersive X-ray (EDX) were demonstrated for screening a cellular phone. For quantitative determination, graphite furnace atomic absorption spectrometry (GF-AAS) was employed. Experimental results for Pb in a battery showed large difference in analytical results in between XRF and GF-AAS, i.e., 0.92% and 5.67%, respectively. In addition, the standard deviation of XRF was extremely large in the range of 23-168%, compared with that in the range of 1.9-92.3% for LA-ICP-MS. In conclusion, GF-AAS was required for quantitative analysis although EDX was used for screening. In this work, it was proved that LA-ICP-MS can be used as a screening method for fast analysis to determine hazardous elements in electrical products.

The Usefulness and Safety of Natural Stent in a Canine Model of Tracheal Stenosis (Nd-YAG laser를 이용한 기관협착 동물모델에서 Natural 스텐트의 안전성 및 유효성 -Dumon 스텐트와의 비교 실험-)

  • Kim, Ho-Joong;Koh, Won-Jung;Suh, Gee-Young;Chung, Man-Pyo;Kim, Jhin-Gook;Suh, Soo-Won;Kwon, O-Jung
    • Tuberculosis and Respiratory Diseases
    • /
    • v.53 no.4
    • /
    • pp.431-438
    • /
    • 2002
  • Background : In order to investigate the usefulness and safety of Natural Stent, we performed this study in a canine model of tracheal stenosis induced using Nd-YAG laser. Materials and Methods : After tracheal stenosis was induced in 12 Mongrel dogs using Nd-YAG laser, either Dumon (n=6) or Natural (n=6) stent was inserted into the trachea. To assess the degree of stent migration and mucostasis, bronchoscopy was performed every week for 4 weeks, after which all stents were removed. One week after stent removal, tracheal stenosis was evaluated by bronchoscopy. Results : The degree of stent migration was not different between the dogs with Dumon stent ($3.0{\pm}0.8$) and those with Natural ($2.0{\pm}1.0$), nor was the degree of mucostasis, at Dumon ($1.7{\pm}0.5$) and Natural Stent ($1.5{\pm}0.6$), respectively. One week after stent removal, the degree of tracheal stenosis was not different between the Dumon ($1.5{\pm}0.5$) and the Natural group ($1.0{\pm}0.4$). In addition, there was no death and the degree of tracheal stenosis remained always within the safe limit (less than 2.0) in all animals. Conclusion : In a canine model of tracheal stenosis induced using Nd-YAG laser, the usefulness and safety of Natural Stent were similar to those of Dumon Stent. A clinical trial is necessary to document the usefulness and safety of Natural Stent in patients with tracheal stenosis.

Military Competition and Arms Control in Space (우주상 군비경쟁과 군비통제)

  • Shin, Dong-Chun;Cho, Hong-Je
    • The Korean Journal of Air & Space Law and Policy
    • /
    • v.26 no.2
    • /
    • pp.203-237
    • /
    • 2011
  • Since USSR successfully launched its satellite "Sputnik"in 1957, many countries including US and USSR began military use of space, and engaged in arms race in space, which is against spirit and ideals of peaceful use of space as common heritage of mankind stipulated in many treaties such as Outer Space Treaty. With worsening Cold War between East and Western Bloc, this military use of space and arms race in space has been intensifying. Regarding the ideals of peaceful use of space, it is interpreted that military use of space is possible unless it does not have the purpose of aggression. The military use of space may have diverse forms such as attacking satellites in space, or attacking from satellites, making use of present and future technologies available which should include the use of nuclear and kinetic/hyper-speed weapons, laser, particle beams, near explosion, disturbance weapons in different directions (i.e., surface to space, space to space, and space to surface). Arms control is being implemented by the efforts of many countries in different formalities including legislature of international treaties under the auspices of UNCOPUOS and prohibition of weapons of mass destruction. Taking outstanding examples aiming at arms control by international community, there are confidence building measures (CBM), strengthening implementation of existing treaties, partial ban of nuclear tests, countryand regional approach, comprehensive approach and measures having legally binding force. While U.S. has surpassed other countries concerned in the area of military useof space, it withdrew from OST in early 2000s, thereby raising concern of international community. It requires concerted efforts of cooperationand implementation by international society to make sure peace of mankind and environmental conservation through arms control in space. Observing de facto possession of nuclear weapons by North Korea following series of nuclear tests and launching satellites, and efforts of launching rockets by South Korea, it is strongly needed for both countries to take part in arms control efforts by international community.

  • PDF

ABRASION AND CHEMICAL DEGRADATION OF LIGHT-CURED COMPOSITE RESIN FOR UPDATED RESIN DEVELOPMENT (차세대 레진개발을 위한 광중합형 복합레진의 마모와 화학적 분해)

  • Yang, Kyu-Ho;Choi, Nam-Ki;Yook, Geun-Young
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.31 no.4
    • /
    • pp.685-695
    • /
    • 2004
  • The aim of this study was to evaluate the resistance to degradation and to compare the wear resistance characteristics of four composite resins in an alkaline solution. The resistance to degradation was evaluated on the basis of mass loss(%), degradation depth(${\mu}m$), Si loss(ppm) and wear depth. The brands studied were Heliomolar flow, Filtek supreme, Point4, Tetric flow. The results were as follows: 1. The sequence of the mass loss was in descending order by Heliomolar flow, Filtek supreme, Point4, Tetric flow. There was significant differences among the materials except Heliomolar flow and Filtek supreme. 2. The sequence of the degree of degradation layer depth was in descending order by Filtek supreme, Heliomolar flow, Tetric flow, Point4. There were significant differences among the materials except Heliomolar flow and Tetric flow. 3. The sequence of Si loss was in descending order by Filtek supreme, Heliomolar flow, Point4, Tetric flow. There were significant differences among the materials except Point 4 and Tetric flow. 4. The sequence of maximum wear depth was in descending order by Heliomolar flow, Point4, Fillet supreme, Tetric flow and there was increasing wear depth on soaking in 0.1N NaOH solution. 5. When observed with SEM, destruction of bonding between matrix and filler was observed and when observed with CLSM, the depth of degradation layer of specimen surface was observed. There results indicate that wear and hydrolytic degradation could be considered to be evaluation factors of composite resins.

  • PDF