• 제목/요약/키워드: 레이저 속도계

검색결과 101건 처리시간 0.023초

광 디스크 드라이브 내부 유동장에 관한 연구 (A Study on Flow Fields in an Optical Disc Drive)

  • 정지원;최명렬;조형희
    • 대한기계학회논문집B
    • /
    • 제29권2호
    • /
    • pp.224-231
    • /
    • 2005
  • The present study investigates flow characteristics in an optical disc drive (ODD). Detailed knowledge of the flow characteristics is essential to analyze flow-induced noise and vibration, forced convection and flow friction loss. The ODD used in a personal computer is used for the experiment and rotating velocity of disc is under the 4500 rpm. Time-resolved velocity component and velocity spectrum are obtained using the laser Doppler anemometry (LDA), and the flow patterns induced by rotating disc in the ODD are calculated by a commercial finite volume method at the same time. The results show that the front holes reduce flow-induced noise and the position of pickup body only affects flow near the window. Furthermore, it is possible for cooling of heat sources in the drive through measuring the flow fields under the tray. In addition, the numerical results are well matched up to the experimental results, therefore, the validation of the numerical results can be achieved. From the validation of numerical results, it is possible to predict the flow characteristics of the region where it is unable to conduct the experiment.

곡관덕트에서 난류맥동유동의 축방향 속도분포와 2차유동속도분포 (Axial Direction Velocity and Secondary Flow Distributions of Turbulent Pulsating Flow in a Curved Duct)

  • 손현철;이홍구;이행남;박길문
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제24권6호
    • /
    • pp.15-23
    • /
    • 2000
  • In the present study, flow characteristics of turbulent pulsating flow in the square-sectional $180^{\circ}$curved duct are investigated experimentally. In order to measure axial direction velocity and secondary flow distributions, experimental studies for air flow are conducted in the square-sectional $180^{\circ}$curved duct by using the LDV system with the data acquisition and the processing system of the Rotating Machinery Resolver (RMR) and the PHASE software. The experiment is conducted on seven sections form the inlet($\phi=0^{\circ}$) to the outlet($\phi=180^{\circ}$) at $30^{\circ}$intervals of the duct. The results obtained from the experimentation are summarized as follows : In the axial direction velocity distributions of turbulent pulsating flow, when the ratio of velocity amplitude (A1) is less than one, there is hardly any velocity change in the section except near the wall and in axial velocity distribution along the phase. The secondary flow of turbulent pulsating flow has a positive value at the bend angle of $150^{\circ}$regardless of the ratio of velocity amplitude. The dimensionless value of secondary flow becomes gradually weak and approaches zero in the region of bend angle $180^{\circ}$without regard to the ratio of velocity amplitude.

  • PDF

비예혼합 역류화염에서 열전대 측정을 적용하기 위한 복사보정에 관한 연구 (A Study On the Radiation Corrections Applied to Thermocouple Measurements in Non-premixed Counterflow Flames)

  • 오율권;허준영;차경옥
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제26권2호
    • /
    • pp.209-218
    • /
    • 2002
  • The temperature field of a counterflow non-premixed flame is investigated using thermocouples of two sizes. A thermal balance is performed on the thermocouple in order to calculate the magnitude of the radiation corrections involved. Both the thermocouple wire and bead are separately considered to be the relevant thermal surface to which convective heat transfer takes place, and from which radiation lasses occur. The flame is also simulated by using a detailed chemical kinetic mechanism in a previously developed computer code. The local thermo-physical properties of the gas mixture, required to calculate the corrections, are determined both from the simulation, and by approximating the properties of the mixture as those of molecular nitrogen at the measured temperatures. It is concluded that the thermocouple wire is the appropriate thermal surface to which radiation corrections apply, in the absence of information about the gas mixture, its properties can be reasonably approximated by those of nitrogen rm ($N_2$), and the radiation corrections are very sensitive to misalignments in the temperature and velocity fields.

밀폐된 원통내부에서 회전체의 형상에 따른 혼합효과에 대한 LDV 측정 (LDV Measurement for the Mixing Effect of the Rotator Shape in a Confined Cylinder)

  • 박천수;김유곤
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집E
    • /
    • pp.720-726
    • /
    • 2001
  • Two-dimensional, angle-resolved LDV(Laser Doppler Velocimetry) measurements of the turbulent rotating flow field in a confined cylinder have been performed. The configurations of interest are flows between a rotating upper disk with a rod attached by a disk or impeller(${\theta}= 90^{\circ},\;45^{\circ}$) and a stationary lower disk in a confined cylinder. The mean flow velocity as well as the turbulent intensity of the flow field have been measured. The results show that the flow is strongly dependent on the position of the impellers or the disk, negligibly affected by the Reynolds number in turbulent flow. It is observed that the mixing effect of the axial flow impeller(${\theta}= 45^{\circ}$) is better than that of the radial flow impeller(${\theta}= 90^{\circ}$) or a disk.

  • PDF

토크 컨버터 내부 유동장 측정 (II) (Flow Field Measurements in a Torque Converter (II))

  • 유성출;장성국
    • 동력기계공학회지
    • /
    • 제13권6호
    • /
    • pp.82-87
    • /
    • 2009
  • LDV measurements were conducted on the planes between impeller blades of torque converter. The flow fields are extremely complex because they contain unsteady viscous three-dimensional flows. Besides of their complexity, the difference in rotor speeds between the impeller and turbine compound the flow effects. The good spatial resolution of the LDV allows measurements of the instantaneous flow structures within the impeller passage, yielding valuable information about the production automotive torque converter in realistic operating conditions. It was found that the mass flow rates are strongly related with the internal flow characteristics of torque converter.

  • PDF

곡관덕트에 난류정상유동의 축방향 속도분포와 벽면전단응력분포 (Axial Direction Velocity and Wall shear Stress Distributions of Turbulent Steady Flow in a Curved Duct)

  • 이홍구;손현철;이행남;박길문
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제25권1호
    • /
    • pp.131-138
    • /
    • 2001
  • In this paper, an experimental investigation of characteristics of developing turbulent steady flows in a square-sectional $180^{\circ}$curved duct is presented. The experimental study using air in a square-sectional $180^{\circ}$ curved duct carryed out to measure axials direction velocity and wall shear stress distrbutions by using Laser Dopper Velocimeter(LDV) system with data acquistion and processing the system of FIND6260 softwere at 7 sections from the inlet($\phi=0^{\circ}$) to the outlet($\phi=180^{\circ}$) in $301^{\circ}$ intervals of a curved duct.

  • PDF

소노루미네센스 현상과 그 응용 (Sonoluminescence Phenomeana and Their Application)

  • 곽호영
    • 기계저널
    • /
    • 제35권8호
    • /
    • pp.725-736
    • /
    • 1995
  • 소노루미네센스(SL)현상은 액체 내에서 초음파에 동기화되어 진동하는 미소기포$~10\mu\textrm{m}$)가 수축할 때 기포내부의 온도가 고온이 됨에 따라 기포중심으로부터 빛이 나오는 현상을 말한다. 단일기 포가 초음파에 가진 될 경우 그 스펙트럼이 X선에 가까운 것임이 밝혀질뿐더러 촉매물 질의 개발이나 활성화, 고분자 합성뿐만 아니라 용액 내에서의 불순물 제거 등에 대한 응용의 가능성이 속속 발견되자, 현재 과학계뿐만 아니라 일반 매스컴에서도 화제의 대상이 되고 있다. SL현상은 원자당 $10^{11}eV$ 에 해당되는 초음파 에너지의 파장이 0.19.mu. 이하인 X선, 즉 6eV 이상의 광자에너지로 증폭됨에 따라 기포수축시 기포내 가스의 온도가 수만 도에 이르는 것, 레이저에 상응하는 광펄스 폭(50 ps)과 초음파에 동기되어 현존하는 최상의 수정시계에 필적하는 SL펄스의 규칙성, 기포수축시의 $10^{10}W/m^{2}$에 해당되는 열의 방출과 10억분의 수 초 동안에 $10^{4}K$의 고온상태에서 200K 정도의 저온상태로 바뀜에 따른 급격한 냉각속도 등 으로 특징지어질 수 있다. 이 글에서는 현재 실험을 통하여 알려진 SL에 관한 현상의 특징과 응용에 대해 구체적으로 기술하였다.

  • PDF

레이저 계측기를 이용한 축의 비틀림 진동에 관한 실험적 기초 연구 (The Experimental and Basic Study on Torsional Vibration of Horizontal Rotating Shaft using a Laser Measuring Equipment)

  • 박일수
    • 동력기계공학회지
    • /
    • 제13권1호
    • /
    • pp.33-38
    • /
    • 2009
  • In this study, the nose of cam in the automobile engine was modelled into circular disk to analyze the torsional vibration of the cam shaft. The distance between disks was fixed, but the diameter of disks was changed. The torsional vibration of the cam shaft was studied experimentally by the motion of the modelled disk with changing the disk diameter. And the sizes of the modelled disk were selected not to show the natural frequencies over all the experimental ranges. The torsional vibration meter used in this study has a laser system with non-contact measurement method, which can measure both torsional angular vibration velocity and torsional angular vibration displacement simultaneously. The Experimental analysis shows that the characteristics of the torsional vibration in the horizontal rotating shaft can be considerably affected by the arrangement of the modelled disks.

  • PDF

토크 컨버터 내부 유동장의 실험적 연구 (An Experimental Study of Flow Field in a Torque Converter)

  • 유성출
    • 한국가시화정보학회지
    • /
    • 제8권4호
    • /
    • pp.19-25
    • /
    • 2010
  • The flow field measurements were conducted on the planes between impeller blades, and the gap between the impeller and turbine blades under speed ratio of 0.4. The study showed that high velocity regions move from locations near the suction surface of the impeller to the pressure blade, shroud corner as flow progresses from the mid-chord of impeller passage to exit and out into the gap region. Planes 3 through 5 also showed flow reversal occurring in the area near the shell surface and progress far into the impeller passage from the impeller passage exit, near shell surface. This affected the converter efficiency negatively. This study would aid in the construction of higher accuracy CFD models of this complex turbomachinery device.

유체속도 측정을 위한 레이저 도플러 유속계의 구성에 관한 연구 (A Study on the Construction of LDV System for a Measurement of the Fluid Velocity)

  • 최종원;조재흥;정명세
    • 전자공학회논문지A
    • /
    • 제28A권5호
    • /
    • pp.361-369
    • /
    • 1991
  • The optics and the signal processor of dual beam laser Doppler velocimeter(LDV) was fabricated. By using the dual beam and the forward scattering, the optics part of LDV was fabricated. And the signal processor of LDV was designed by the frequency counter type using new 11:6 period timing device in order to remove error signals, and was made of the reference clock of a 500 MHz ECL oscillator. Doppler frequencies from 10KHz to 70MHz can be measured using the signal processor. In the accuracy of the period counting part, from 1.81x10**-4% to 1.27% is estimated, and in the accuracy of the validation logic part, from 0.78% to 14.78% is estimated.

  • PDF