A Study on Improvement of Operation Characteristics and Inspection Method of Standby Power Supply such as Emergency Induction Light using Li-ion Capacitor (리튬이온커패시터를 활용한 비상유도등 예비전원장치의 동작 특성 및 점검방법 개선에 관한 연구)

  • Jung, Jun-Chea
    • Journal of the Society of Disaster Information
    • /
    • v.16 no.2
    • /
    • pp.392-401
    • /
    • 2020
  • Purpose: This study analyzes the operating characteristics of a lithium ion capacitor that can be used as a standby power supply in an emergency, and determines whether the standby power supply is abnormal even by measuring the voltage using a linear proportionality characteristic during charging and discharging. The aim is to provide an experimental basis that can be done. Method: As a method for this study, first, analyze the operation principle and characteristics of the existing backup power supply and lithium ion capacitor, and then measure the voltage of the lithium ion capacitor according to the configuration and system block diagram of the induction lamp used in the experiment. We proceed with the test of the measured value of discharge power for each voltage band to check the amount of power held by the battery and the operation test experiment using induction lamps. Results: Just by checking the charging voltage using the linear proportional characteristics of lithium ion capacitors, it provides a basis for accurately inferring the effective operating time of induction lamp lamps. Conclusion: In the event of a disaster, the lithium ion capacitor is used as a spare power supply for emergency induction lamps to prevent complete discharge of emergency induction lamps, to prevent the problem of performing normal operation of the standby power supply, and to use only a simple voltage measurement to reserve power. It was intended to suggest many uses for evacuation equipment application in the future by making it possible to check whether the device is abnormal.

Development of an IoT Device for Detecting Escherichia coli from Various Agri-Foods and Production Environments (IoT 적용 대장균 검출기 개발과 농식품 및 생산환경에 적용)

  • Nguyen, Bao Hung;Chu, Hyeonjin;Kim, Won-Il;Hwang, Injun;Kim, Hyun-Ju;Kim, Hwangyong;Ryu, Kyoungyul;Kim, Se-Ri
    • Journal of Food Hygiene and Safety
    • /
    • v.34 no.6
    • /
    • pp.542-550
    • /
    • 2019
  • To detect Escherichia coli from agri-food and production environments, a device based on IoT (internet of things) technology that can check test results in real time on a mobile phone has been developed. The efficiency of the developed device, which combines an incubator equipped with a UV lamp, a high-resolution camera and software to detect E. coli in the field, was evaluated by measuring the device's temperature, detection limit, and detection time. The device showed a difference between its programmed temperature setting and actual temperature of about 1.0℃. In a detection limit test performed with a single-colony inoculation, a color change to yellow and a florescent signal were detected after 12 and 15 h incubations, respectively. The incubation time also decreased along with increasing bacteria levels. When applying the developed method and device to various samples, including utensils, gloves, irrigation water, seeds, and vegetables, detection rates of E. coli using the device were higher than those of the Korean Food Code method. These results show that the developed protocol and device can efficiently detect E. coli from agri-food production environments and vegetables.

Grade Classification of Urushi Lacquer (I) Grade Classification of Urushi Lacquer by Traditional Method (옻칠의 품등 구분 (I) 전통적인 방법에 의한 옻칠의 품등구분)

  • Roh, Jeong-Kwan;Kim, Yun-Geun
    • Journal of the Korean Wood Science and Technology
    • /
    • v.36 no.6
    • /
    • pp.105-112
    • /
    • 2008
  • Grading of the urushi lacquer is quite difficult because of large variations depending on origin, growing conditions, time acquisition, storage conditions. It is urgently required to establish a grading system of urushi lacquer by combining traditional method with scientific methods. Traditional grading of urushi lacquer was done by visual inspection of 10 experts who are working on urushi lacquer industry. Common aspects of the experts were color, odor, viscosity, spread properties on Hanji, color and drying properties on glass based the traditional grading system. In addition, rubbing on Hannj and heating with alcohol lamp was also used to grade urushi lacquer. The grading results of 10 experts showed that chinese urushi lacquer (E) of 7.03, japanese urushi lacquer (C) of 6.84, domestic urushi lacquer of (A) of 6.41 and another chinese urushi lacquer (D) of 5.27, and domestic urushi lacquer (B) of 2.50 in descending order. The degree of spread on Hanji was not consistent among 10 experts. These results indicated that the traditional grading system was pretty much personal and required of developing more objective method based on scientific background.

A Fundamental Study of Eu2+ Luminescence in Aluminum Borate Compounds (Aluminum Borate 화합물에 있어서 EU2+이온의 발광성)

  • Chang, Ki-Seog
    • Journal of the Korean Chemical Society
    • /
    • v.44 no.4
    • /
    • pp.350-355
    • /
    • 2000
  • The compounds, CaAl$_2$(BO$_3$)$_2$O, SrAl$_2$(BO$_3$)$_2$O and BaAl$_2$(BO$_3$)$_2$O, are good host lattices for highly efficient $Eu^{2+}$ luminescence. The europium emission peaks at 450 nm in $Eu^{2+}$:CaAl$_2$(B0$_3$)$_2$O, 411 nm in $Eu^{2+}$: SrAl$_2$(BO$_3$)$_2$O and 375 nm in $Eu^{2+}$: BaAl$_2$(BO$_3$)$_2$O. The $Eu^{2+}$: CaAl$_2$(BO$_3$)$_2$O Phosphor shows a high output and should be a good maintenance in VUV Xe lamps. It is ideally suited for use in PDP phosphors. The $Eu^{2+}$ ion is interesting because the Stokes shift emission is a strong host dependent. The difference in the Stokes shift is oneimportant factor leadingto a difference in wavelength. If the 5d level of $Eu^{2+}$ ion is lower in energy,according to a decrease in the doping lattice size, then the emission wavelength will be longer and the Stokes shift will be smaller. Therefore, a knowledge of the relationship between the crystal lattice size and the Stokes shift. (orthe energy of the 5d level),is essential for beingable to predict $Eu^{2+}$ emission properties.

  • PDF

Growth and optical characteristics of the non-phosphor white LED by mixed-source HVPE (혼합소스 HVPE에 의한 비형광체 백색 LED의 성장과 광 특성)

  • Kim, E.J.;Jeon, H.S.;Hong, S.H.;Han, Y.H.;Lee, A.R.;Kim, K.H.;Ha, H.;Yang, M.;Ahn, H.S.;Hwang, S.L.;Cho, C.R.;Kim, S.W.
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.19 no.2
    • /
    • pp.61-65
    • /
    • 2009
  • In this paper, we report on the growth and optical characteristics of white-LED without fluorescent material. The growth of DH(double heterostructure) with AlGaN active layer was performed on a n-GaN/(0001) $Al_{2}O_{3}$ by the mixed-source HVPE and multi-sliding boat. The CRI(color rendering index) of packaging device charged in the range 72-93 with CIE chromaticity coordinates(x=$0.26{\sim}0.34$, y=$0.31{\sim}0.40$). And CCT(correlated color temperature) values was measured $5126{\sim}10406K$ with increasing injection current. The CIE point of conventional phosphor white LED shifts blue region, but cm point of non-phosphor white LED shifts opposite direction. These results show the mixed-source HVPE can be possible to newly fabricate method of phosphor free white LED with high CRI value.

Evaluation of New LED Curing Light on Resin Composite Polymerization (발광 다이오드 광중합기의 복합레진 중합 평가)

  • Kang, Jieun;Jun, Saeromi;Kim, Jongbin;Kim, Jongsoo;Yoo, Seunghoon
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.41 no.2
    • /
    • pp.152-156
    • /
    • 2014
  • The purpose of this study is to compare efficiency of broad spectrum LEDs ($VALO^{(R)}$, Ultradent, USA) with conventional LED curing lights ($Elipar^{TM}$ Freelight 2, 3M ESPE, USA) using a microhardness test. The light curing units used were $VALO^{(R)}$ in three different modes and $Elipar^{TM}$ Freelight 2. The exposure time was used according to the manufacturer's instructions. After cured resin specimens were stored in physiological saline at $37^{\circ}C$ for 24 hours, microhardness was measured using Vickers microhardness tester. The microhardness of upper and lower sides of the specimens were analyzed separately by the ANOVA method (Analysis of Variance) with a significance level set at 5%. At upper side of resin specimens, an increased microhardness was observed in the broad spectrum LED curing light unit with a high power mode for 4 seconds and plasma emulation mode for 20 seconds (p < 0.05). However, at the lower side of resin specimens, there were no significant differences in microhardness between broad spectrum LED curing light unit and conventional LED curing light unit.

Effects of UV Sterilization on Quality of Acer mono Sap (자외선 살균이 고로쇠 수액의 품질에 미치는 영향)

  • Choe, Su Bin;Han, Sang Jin;Han, Ouk Hee;Kim, Hak Su;Kang, Sung Tae
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.42 no.1
    • /
    • pp.148-152
    • /
    • 2013
  • An ultraviolet (UV) sterilization system was developed to decrease the number of microorganisms in filtered Acer mono sap (FAS). The Acer mono sap (AS) was passed through 18 strips of PTA fluoroplastic tubing with 30 UV lamps (total 1,170 W). During passage, the AS was effectively exposed to the UV rays. The total bacteria, coliform group and fungi were sterilized at a flow rate ranging from 852 to 1,358 mL/min and a UV power higher than 156 W. Although the sensory score of the UV-sterilized AS was significantly lower than that of the untreated AS, the sensory score was better under the condition of 390 W and 852~1,358 mL/min than under the other conditions examined. ANOVA did not reveal a significant difference in pH, total acidity, sugar content and color characteristic under all conditions tested (p<0.05). Considering the overall attributes of the AS quality, the optimum sterilization condition was determined to be 390 W and 852~1,358 mL/min.

Evaluation of Unexposed Images after Erasure of Image Plate from CR System (CR 시스템에서 IP 잠상의 소거 후 Unexposed Image의 평가)

  • Lim, Bo-Yeon;Park, Hye-Suk;Kim, Ju-Hye;Park, Kwang-Hyun;Kim, Hee-Joung
    • Progress in Medical Physics
    • /
    • v.20 no.4
    • /
    • pp.199-207
    • /
    • 2009
  • It is important to initialize Image Plate (IP) completely for removing residual latent image by sodium lamp for reliability and repeatability of computed radiography (CR) system. The purpose of this study was to evaluate latent images of computed radiography (CR) images respect to delay time after erasure of foregone latent image and its effect, and erasure level. Erasure thoroughness for CR acceptance test from American Association of Physicist in Medicine (AAPM) Report 93 (2006) was also evaluated. Measurements were made on a CR (Agfa CR 25; Agfa, BELGIUM) system. Chest postero-anterior (PA), Hand PA, L-spine lateral radiographs were chosen for evaluation. Chest phantom (3D-torso; CIRS, USA) was used for Chest PA and L-spine lateral radiography. For Hand PA radiography, projections was done without phantom. Except Hand PA radiographs, noise was increased with delay time, and ghost image was appeared on overexposed area. Effect of delay after erasure on latent image was not seen on naked eye, but standard deviation (SD) of pixel value on overexposed area was relatively higher than that of other areas. On Hand PA and Chest PA radiographs, noise were not occurred by adjustment of erasure level. On L-spine lateral images at lower erasure level than standard level, noise including ghost image were occurred because of high tube current. Erasure thoroughness of CR system in our department was to be proved by these evaluation. The results of this study could be used as a baseline for IP initialization and reliability of CR images.

  • PDF

Changes in Quality of UV Sterilized Takju during Storage by Honeycomb Type-UV Sterilizer (허니컴방식 UV 살균기를 이용한 살균 탁주의 저장 중 품질변화)

  • Lee, Jang-Woon;Jung, Jin-Joo;Choi, Eun-Ju;Kang, Sung-Tae
    • Korean Journal of Food Science and Technology
    • /
    • v.41 no.6
    • /
    • pp.652-656
    • /
    • 2009
  • A cylindrical ultraviolet (UV) sterilization system was developed for decreasing microorganisms in takju. The takju was passed through 110 strips of honeycomb-type teflon tubing with 9 UV lamps (1,395 W) set between the teflon tubes. Thus, during passage, the takju was effectively exposed to the UV rays without loss. In terms of the overall quality aspects of the takju, the optimum sterilization condition was set for 4 min at 2 L/min. A 2-3 log cycle decrease in viable cell numbers of total bacteria and fungi was observed at this operating condition. Quality changes in the UV-sterilized takju were examined via UV irradiation of samples followed by storage at 30oC for 8 days. To evaluate the quality changes, pH, amino nitrogen content, acidity, reducing sugar content, and viable cell numbers of total bacteria and fungi were measured. Increases in pH, acidity, and amino nitrogen content were observed in both the takju control and UV sterilized takju with increasing storage time. However, reducing sugar content was decreased in both samples. The L, a, and b values of the control takju and UV sterilized takju showed similar trends over the storage period. Viable cell numbers of fungi did not change in the control or UV sterilized takju during storage, showing approximately $10^8\;CFU/mL$ and $10^4-10^5\;CFU/mL$, respectively. In addition, viable cell numbers of total bacteria remained lower in the UV sterilized takju over 4 days compared to the non-sterilized takju.

Design of Adaptive Neuro-Fuzzy Inference System Based Automatic Control System for Integrated Environment Management of Ubiquitous Plant Factory (유비쿼터스 식물공장의 통합환경관리를 위한 적응형 뉴로-퍼지 추론시 스템 기반의 자동제어시스템 설계)

  • Seo, Kwang-Kyu;Kim, Young-Shik;Park, Jong-Sup
    • Journal of Bio-Environment Control
    • /
    • v.20 no.3
    • /
    • pp.169-175
    • /
    • 2011
  • The adaptive neuro-fuzzy inference system (ANFIS) based automatic control system framework was proposed for integrated environment management of ubiquitous plant factory which can collect information of crop cultivation environment and monitor it in real-time by using various environment sensors. Installed wireless sensor nodes, based on the sensor network, collect the growing condition's information such as temperature, humidity, $CO_2$, and the control system is to monitor the control devices by using ANFIS. The proposed automatic control system provides that users can control all equipments installed on the plant factory directly or remotely and the equipments can be controlled automatically when the measured values such as temperature, humidity, $CO_2$, and illuminance deviated from the decent criteria. In addition, the better quality of the agricultural products can be gained through the proposed automatic control system for plant factory.