A study on image region analysis and image enhancement using detail descriptor (디테일 디스크립터를 이용한 이미지 영역 분석과 개선에 관한 연구)

  • Lim, Jae Sung;Jeong, Young-Tak;Lee, Ji-Hyeok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.6
    • /
    • pp.728-735
    • /
    • 2017
  • With the proliferation of digital devices, the devices have generated considerable additive white Gaussian noise while acquiring digital images. The most well-known denoising methods focused on eliminating the noise, so detailed components that include image information were removed proportionally while eliminating the image noise. The proposed algorithm provides a method that preserves the details and effectively removes the noise. In this proposed method, the goal is to separate meaningful detail information in image noise environment using the edge strength and edge connectivity. Consequently, even as the noise level increases, it shows denoising results better than the other benchmark methods because proposed method extracts the connected detail component information. In addition, the proposed method effectively eliminated the noise for various noise levels; compared to the benchmark algorithms, the proposed algorithm shows a highly structural similarity index(SSIM) value and peak signal-to-noise ratio(PSNR) value, respectively. As shown the result of high SSIMs, it was confirmed that the SSIMs of the denoising results includes a human visual system(HVS).

The Study on the Reduction of Patient Surface Dose Through the use of Copper Filter in a Digital Chest Radiography (디지털 흉부 촬영에서 구리필터사용에 따른 환자 표면선량 감소효과에 관한 연구)

  • Shin, Soo-In;Kim, Chong-Yeal;Kim, Sung-Chul
    • Journal of radiological science and technology
    • /
    • v.31 no.3
    • /
    • pp.223-228
    • /
    • 2008
  • The most critical point in the medical use of radiation is to minimize the patient's entrance dose while maintaining the diagnostic function. Low-energy photons (long wave X-ray) among diagnostic X-rays are unnecessary because they are mostly absorbed and contribute the increase of patient's entrance dose. The most effective method to eliminate the low-energy photons is to use the filtering plate. The experiments were performed by observing the image quality. The skin entrance dose was 0.3 mmCu (copper) filter. A total of 80 images were prepared as two sets of 40 cuts. In the first set (of 40 cuts), 20 cuts were prepared for the non-filter set and another 20 cuts for the Cu filter of signal + noise image set. In the second set of 40 cuts, 20 cuts were prepared for the non-filter set and another 20 cuts for the Cu filter of non-signal image (noisy image) with random location of diameter 4 mm and 3 mm thickness of acryl disc for ROC signal at the chest phantom. P(S/s) and P(S/n) were calculated and the ROC curve was described in terms of sensitivity and specificity. Accuracy were evaluated after reading by five radiologists. The number of optically observable lesions was counted through ANSI chest phantom and contrast-detail phantom by recommendation of AAPM when non-filter or Cu filter was used, and the skin entrance dose was also measured for both conditions. As the result of the study, when the Cu filter was applied, favorable outcomes were observed on, the ROC Curve was located on the upper left area, sensitivity, accuracy and the number of CD phantom lesions were reasonable. Furthermore, if skin entrance dose was reduced, the use of additional filtration may be required to be considered in many other cases.

  • PDF