• Title/Summary/Keyword: 디지털 총의치

Search Result 35, Processing Time 0.018 seconds

Evaluation of occlusal strength using T-Scan Novus and Dental prescale II in dental prosthodontic treatments: A case report (보철물 수복 형태에 따른 T-Scan Novus와 Dental prescale II를 이용한 교합력 평가 활용 증례)

  • Su-Hyun Choi;Yu-Sung Choi;Jong-Hyuk Lee;Seung-Ryong Ha
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.61 no.2
    • /
    • pp.160-178
    • /
    • 2023
  • Diagnosis and analysis of occlusal relationships are important factors in prosthetic treatment. A thorough occlusion analysis and evaluation should be performed before treatment to restore a stable interocclusal relationship. Analysis and evaluation are essential during the treatment process and at regular follow-ups. Recently, with the development of dental equipment and digital processing methods, new quantitative analysis methods that can record the patient's occlusal relationship have been introduced. Among them, the T-Scan Novus (Tekscan Inc., S. Boston, MA, USA) displays the strength of the initial contact point and the occlusal contact point of the teeth using a pressure sensor. With this, occlusal contact time of the teeth, anteroposterior and left-right balance of occlusal force can be compared. The Dental prescale II (GC Co., Tokyo, Japan) scans the occlusal contact point using a pressure-sensing film and analyzes the density of the contact point. It can measure the distribution and strength of the occlusal force of the teeth in the most natural occlusion state. Based on this, appropriate prosthetic treatment (four-unit fixed partial denture, removable partial denture, complete denture, and complete oral restoration cases) was performed according to the area and extent of the patient's tooth loss. The patient's occlusion at the first visit, treatment stage, right after treatment, and regular follow-up were compared and evaluated using a quantitative method for appropriate occlusion analysis using T-Scan Novus and Dental prescale II. This report enhances the understanding of occlusion analysis during prosthetic restoration. The results satisfied both the clinician and patients in terms of function and aesthetics.

Accuracy of CAD-CAM RPD framework according to manufacturing method: A literature review (국소의치 구조물(framework)의 CAD-CAM 제조방식에 따른 정확도: 문헌고찰)

  • Yi, Yuseung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.3
    • /
    • pp.370-378
    • /
    • 2021
  • Purpose. The purpose of this study was to evaluate the currently published literatures investigating the accuracy of computer-aided design and computer-aided manufacturing removable partial denture (CAD-CAM RPD) framework with different manufacturing techniques and methods. Materials and methods. A comprehensive search for literatures was conducted in PubMed database using specific keywords with the patient, intervention, comparison, and outcome (PICO) question, "Is there a difference in accuracy of RPD frameworks manufactured using digital workflow according to the manufacturing process and methods?" Results. A total of 7 articles were selected. Two studies compared intraoral scanning and laboratory scanning for RPD frameworks and had heterogenous results. In the studies using different manufacturing process, RPD frameworks had clinically acceptable accuracy in both subtractive and additive manufacturing. Polyetheretherketone (PEEK)-milled RPD frameworks showed higher fit accuracy than traditionally casted or 3D printed RPDs. Direct milling method showed a higher accuracy than indirect milling method. However, in rapid prototyping, indirect method showed higher accuracy than direct method. Conclusion. The RPD frameworks fabricated using CAD-CAM technology showed a clinically acceptable level of accuracy regardless of manufacturing process or techniques. Consistent results have not been reported regarding the digital impression methods, which were intra oral scanning or laboratory scanning, and further studies are needed.

All-on-4 implant restoration with full-digital system preserving existing occlusion: A case report (완전 디지털 시스템으로 기존 교합을 보전한 All-on-4 임플란트 수복증례)

  • Kim, Kyoung Hee;Jeong, Seung-Mi;Lee, Ye Chan;An, Xue Yin;Choi, Byung-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.56 no.4
    • /
    • pp.330-337
    • /
    • 2018
  • In edentulous patients, implant - supported fixed prosthesis treatment has been proved to be useful, but involves complex treatment process. On the other hand, in the modern dentistry, digital technology has been developed day by day and it has expanded its range to the implant restoration of edentulous patients. In this case, a digital system was used for all stages of diagnosis, surgery, design and fabrication of provisional implants fixed prosthesis restoration in 66-year-old mandibular edentulous patients. In the preoperative diagnosis stage, a provisional restoration was designed based on the mucosal scan using the intraoral scanner and the stable occlusion of prefabricated complete denture of the patient. After flapless implant surgery using the surgical guide, the prefabricated interim restoration was connected to the implant and used as immediate provisional restoration. The final restoration was designed and fabricated by transferring the vertical dimension and the centric relation of the provisional restoration with stable occlusion using digital technology. We report a simple protocol of implant treatment in edentulous patients by using digital techniques to preserve the patient's vertical dimension and occlusion.

Full mouth rehabilitation using 3D printed crowns and implant assisted removable partial denture for a crossed occlusion: a case report (3D 프린팅 금관과 임플란트 보조 국소의치를 이용한 엇갈린 교합의 전악 수복 증례)

  • Sung-Hoon Lee;Seong-Kyun Kim;Seong-Joo Heo;Jai-Young Koak;Ji-Man Park
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.61 no.4
    • /
    • pp.367-378
    • /
    • 2023
  • With the recent development of computer-aided design-computer-aided manufacturing technology and 3D printing technology, and the introduction of various digital techniques, the accuracy and efficiency of top-down definitive prosthetic restoration are increasing. In this clinical case, stable occlusion support was obtained through the placement of a total of 9 maxillary and mandibular posterior implants in patient with anterior-posterior crossed occlusion. The edentulous area of the maxillary anterior teeth, which showed a tendency of high resorption of the residual alveolar bone, was restored with a Kennedy Class IV implant assisted removable partial denture to restore soft tissue esthetics. Computed tomography guided surgery was used to place implants in the planned position, double scan technique was used to reflect the stabilized occlusion in the interim restoration stage to the definitive prostheses, and metal 3D printing was used to manufacture the coping and framework. This clinical case reports that efficient and predictable top-down full mouth rehabilitation was achieved using various digital technologies and techniques.

Fixed prosthesis restoration in edentulous patient fully implanted without considering definitive prosthesis: A case report (최종 보철물에 대한 고려 없이 전악 임플란트 식립된 환자의 고정성 보철 수복 증례)

  • Chun, Young-Hoon;Pae, Ahran;Kwon, Kung-Rock;Kim, Hyeong-Seob
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.55 no.4
    • /
    • pp.427-435
    • /
    • 2017
  • The most important factor in the treatment of fully edentulous patients using implants is the shape of the definitive prosthesis. After the shape of the definitive prosthesis is determined, residual bone analysis and selection of the implant type, number and position should be followed. In this case, for restoration of an edentulous patient fully implanted (except the maxillary right lateral incisor) without considering definitive prosthesis, facial esthetics and possibility of fixed type prosthesis were evaluated using complete denture. It was determined that the fixed type prosthesis was possible. Implants that could not be used for the definitive prosthesis were excluded from the treatment plan and fixed type provisional restorations were fabricated. After four months of provisional restorations, the patient showed stable occlusion and esthetic satisfaction. Definitive prosthesis was made of zirconia using CAD/CAM (computer aided design and computer aided manufacturing). The results were satisfactory during the 3 months of follow-up period after termination of treatment.