• Title/Summary/Keyword: 디지털 진단

Search Result 735, Processing Time 0.027 seconds

Clinical Usefulness of Digital ECG Recorder in Dogs : 4 Cases (디지털 심전도기의 임상적 적용 예 : 4 증례)

  • Moon, Hyeong-Sun;Lee, Seung-Gon;Hyun, Chang-Baig
    • Journal of Veterinary Clinics
    • /
    • v.24 no.2
    • /
    • pp.218-224
    • /
    • 2007
  • Digital electrocardiogram (ECG) recorders are rapidly replacing to conventional paper ECG recorders. Digital ECG recorders have several advantages over conventional type ECG recorders, including better capability for data storage, better portability and better applicability in clinical settings. In this study, we presented 4 case studies related to cardiac rhythm disturbances, which were diagnosed and managed using a digital ECG recorder.

'All-on-4' fixed implant supported prosthesis restoration using digital workflow: a case report (Digital workflow를 활용한 'All-on-4' 임플란트 지지 고정성 보철물 수복 증례)

  • Sungwoo Ju;Seoung-Jin Hong;Janghyun Paek;Kwantae Noh;Ahran Pae;Kung-Rock Kwon;Hyeong-Seob Kim
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.61 no.4
    • /
    • pp.316-327
    • /
    • 2023
  • In the case of fully edentulous patients with severe alveolar bone resorption, the consideration of 'All-on-X' implant-supported fixed prosthesis after placing four or more implants in the anterior maxilla is possible. Recent advancements in digital dentistry have enabled systematic and predictable treatment in all phases, including diagnosis, surgery, and prosthesis fabrication. By incorporating digital dentistry techniques such as digital complete denture, implant surgical guides, facial scanning into the conventional restoration process, it is possible to reduce the complexity of the prosthesis fabrication and effectively achieve the transition from provisional prosthesis to definitive prosthesis in terms of both aesthetics and function.

A Model for Constructing Learner Data in AI-based Mathematical Digital Textbooks for Individual Customized Learning (개별 맞춤형 학습을 위한 인공지능(AI) 기반 수학 디지털교과서의 학습자 데이터 구축 모델)

  • Lee, Hwayoung
    • Education of Primary School Mathematics
    • /
    • v.26 no.4
    • /
    • pp.333-348
    • /
    • 2023
  • Clear analysis and diagnosis of various characteristic factors of individual students is the most important in order to realize individual customized teaching and learning, which is considered the most essential function of math artificial intelligence-based digital textbooks. In this study, analysis factors and tools for individual customized learning diagnosis and construction models for data collection and analysis were derived from mathematical AI digital textbooks. To this end, according to the Ministry of Education's recent plan to apply AI digital textbooks, the demand for AI digital textbooks in mathematics, personalized learning and prior research on data for it, and factors for learner analysis in mathematics digital platforms were reviewed. As a result of the study, the researcher summarized the factors for learning analysis as factors for learning readiness, process and performance, achievement, weakness, and propensity analysis as factors for learning duration, problem solving time, concentration, math learning habits, and emotional analysis as factors for confidence, interest, anxiety, learning motivation, value perception, and attitude analysis as factors for learning analysis. In addition, the researcher proposed noon data on the problem, learning progress rate, screen recording data on student activities, event data, eye tracking device, and self-response questionnaires as data collection tools for these factors. Finally, a data collection model was proposed that time-series these factors before, during, and after learning.

Reduction of Patient Dose Exposure and Improvement of Image Quality by Use of Additional Filtration in Digital Radiology (디지털 진단방사선촬영에서 부가여과판 사용에 따른 피폭선량 감소와 화질 개선)

  • Moon, Su-Jeong;Kim, Young-Keun;Lee, Seong-Kil
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.12 no.1
    • /
    • pp.19-25
    • /
    • 2010
  • This study is mainly for the reduction of exposure dose by using a heavy elements filter(Gd) in the digital radiology. They contained heavy elements filter of Gd and X-ray beam hardening filters such as Al and Cu. According to the results of experimental evaluation, X-ray property was not changed with variety of kVp in the case of the Gd filter. The surface dose and absorption dose were increased in order of Cu and Al. The contrast of image showed the higher value in order of Cu, Al and Gd. While the use of Gd has increased the numerical value of the CR image, and grayscale has decreased noise value of the DR image.

  • PDF

A study on developing a new self-esteem measurement test adopting DAP and drafting the direction of digitalizing measurement program of DAP (청소년 자존감 DAP 인물화 검사 개발 및 디지털화 측정 시스템 방향성 연구)

  • Woo, Sungju;Park, Chongwook
    • Journal of the HCI Society of Korea
    • /
    • v.8 no.1
    • /
    • pp.1-9
    • /
    • 2013
  • This is to develop a new way of testing self-esteem by adopting DAP(Draw a Person) test and to make a platform to digitalize it for young people in the adolescent stage. This approach is to get high effectiveness of the self-esteem measurement using DAP test, including some personal inner situations which can be easily missed in the large statistical analysis. The other objective of this study is digitalize to recover limits of DAP test in the subjective rating standard. It is based on the distribution of the figure drawing expressed numerically by the anxiety index of Handler. For these two examinations, we made experiment through 4 stages with second grade middle school 73 students from July 30th to October 31th in 2009 during 4 months. Firstly, we executed 'Self Values Test' for all 73 people, and divided them into two groups; one is high self-esteem group of 36 people, the other is low self-esteem group of 37 people. Secondly, we regrouped them following D (Depression), Pd (Psychopathic Deviate), Sc (Schizophrenia) scales of MMPI; one is high self-esteem group of 7 people, the other is low self-esteem group of 13 people. Thirdly, we conducted DAP test separately for these 20 people. We intended to verify necessity and appropriateness of direction of 'Digitalizing Measurement System' by comparing and analyzing relation between DAP and Self-esteem following evaluation criteria which has similarity in 3 tests, after executing DAP to reflect peculiarity of adolescents sufficiently. We compared and analyzed result abstracted by sampling DAP test of two groups; One is high self-esteem group of 2 people, the other is low self-esteem group of 2 people; to confirm whether we can improve limitation that original psychological testing has by comparing mutual reliance of measurement test. Finally, with DAP test gained from correlations between self-esteem and melancholia following as above-mentioned steps, we discovered possibility of realization to get a concrete and individual criteria of evaluation based on Expert System as a way of enhancing accessibility in quantitative manner. 'Digitalizing Measurement Program' of DAP test suggested in this study promote results' reliability based on existing tests and measurement.

  • PDF

The Value of Three-Dimensional Reconstructions of MRI Imaging using Maximum Intensity Projection Technique (유방 MRI의 최대강도투사 기법에 의한 3차원 재구성 영상의 유용성)

  • Cho, Jae-Hwan;Lee, Hae-Kag;Hong, In-Sik;Kim, Hyun-Joo;Jang, Hyun-Cheol;Park, Cheol-Soo;Park, Tae-Nam
    • Journal of Digital Contents Society
    • /
    • v.12 no.2
    • /
    • pp.157-164
    • /
    • 2011
  • The purpose of this study was to examine the usefulness of 3D reconstruction images in breast MRI by performing a quantitative comparative analysis in patients diagnosed with DCIS. On a 3.0T MR scanner, subtraction images and 3D reconstruction images were obtained from 20 patients histologically diagnosed with ductal carcinoma in situ (DCIS). The findings from the quantitative image analysis are the following: The 3D reconstruction images showed higher SNR at the lesion area, ductal area, and fat area that of the subtraction image. In addition, the CNR were not significantly different in the lesion area itself between the subtraction images and 3D reconstruction images.

A Way for Maximum Use of Cancer Risk Assessment System CARA (암 발생 위험도 분석 시스템 CARA의 활용도 극대화 방안)

  • Yang, Gi-Chul;Cho, Kwang-Moon
    • Journal of Digital Convergence
    • /
    • v.10 no.3
    • /
    • pp.121-126
    • /
    • 2012
  • In this paper, a way for maximum use of cancer risk assessment software system CARA which can assess cancer risks by using health related information only without doctor's diagnosis is proposed. A way of maximizing the usage of CARA with use of nation wide internet network is described along with the general description of CARA. If CARA is used, the damage causing by cancer can be reduced since it is possible to sort a group of people with high risks (before diagnosis at a hospital). Also, CARA is helpful for medical research by used as a tool to reveal correlations between personal information and cancers practically. Unlike other preexisting systems, CARA is a new system which can consider 30 different cancers simultaneously and it is very efficient for early detection of cancer.

진단 X-ray 범위에서의 Plasma Display Panel의 X-ray에 대한 전기적 반응 특성 평가

  • Heo, Eun-Sil;Yun, Min-Seok;Jeong, Jae-Hun;Lee, Yeong-Gyu;Mun, Chi-Ung;Gang, Sang-Sik;Nam, Sang-Hui
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.06a
    • /
    • pp.373-373
    • /
    • 2010
  • 본 논문에서는 Display용 PDP(Plasma Display panel)를 디지털 X-ray Detector로 적용하기 위해 Panel 내 Xe gas와 Ne gas의 비율을 달리하며 X-ray에 대한 기본적인 전기적 반응 특성을 연구하였다. 연구에 사용된 panel 은 상용화된 Display용 PDP를 5inch의 크기로 소형화한 sample을 제작하여 사용하였다. 제작된 sample panel의 구조는 기본적으로 Display용 PDP의 구조와 일치한다. 제작된 Sample panel의 X-선 검출기로서의 전기적 특성을 조사하기 위해 기본적인 전기특성인 Dark current, X-ray sensitivity, 그리고 Linearity를 측정하였다. 측정 결과, 진단 범위에서 충분한 전기적 Sensitivity 보이며, 선형적 특성 또한 우수한 결과를 보이는 등 안정된 전기적 동작특성을 보였다. 이러한 결과로부터 기존에 사용되어오던 Display용 PDP에 새로운 X선 변환층을 추가하고, 효율을 더욱 높일 수 있는 구조 변경을 통하여 상용화된 PDP를 디지털 X-선 검출기로서의 적용 가능성을 확인할 수 있었다.

  • PDF

A Study of Digitalizing Analog Gamma Camera Using Gamma-PF Board (Gamma-PF 보드를 이용한 아날로그 감마카메라의 디지털화 연구)

  • Kim, Hui-Jung;So, Su-Gil;Bong, Jeong-Gyun;Kim, Han-Myeong;Kim, Jang-Hwi;Ju, Gwan-Sik;Lee, Jong-Du
    • Journal of Biomedical Engineering Research
    • /
    • v.19 no.4
    • /
    • pp.351-360
    • /
    • 1998
  • Digital gamma camera has many advantages over analog gamma camera. These include convenient quality control, easy calibration and operation, and possible image quantitation which results in improving diagnostic accuracies. The digital data can also be utilized for telemedicine and picture archiving and communication system. However, many hospitals still operate analog cameras and have difficult situation to replace them with digital cameras. We have studied a feasibility of digitalizing an analog gamma camera into a digital camera using Gamma-PF interface board. The physical characteristics that we have measured are spatial resolution, sensitivity, uniformity, and image contrast. The patient's data obtained for both analog and digital camera showed very similar image quality. The results suggest that it may be feasible to upgrade an analog camera into a digital gamma camera in clinical environments.

  • PDF

The Novel Label Free Staining Algorithm in Digital Pathology (차세대 디지털 병리를 위한 Label Free 디지털염색 알고리즘 비교 연구)

  • Seok-Min Hwang;Yeun-Woo Jung;Dong-Bum Kim;Seung Ah Lee;Nam Hoon Cho;Jong-Ha Lee
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.24 no.1
    • /
    • pp.76-81
    • /
    • 2023
  • To distinguish cancer cells from normal cells, H&E (Hematoxylin & Eosin) staining is required. Pathological staining requires a lot of money and time. Recently, a digital dyeing method has been introduced to reduce such cost and time. In this paper, we propose a novel digital pathology algorithms. The first algorithm is the Pair method. This method learns the dyed phase image and unstained amplitude image taken by FPM (Fourier Ptychographic Microscopy) and converts it into a dyed amplitude image. The second algorithm is the unpair method. This method use the stained and unstained fluorescence microscopic images for modeling. In this study, digital staining was performed using a generative adversarial network (GAN). From the experimental results, we noticed that both the pair and unpair algorithms shows the excellent performance.