• Title/Summary/Keyword: 디지털 영상상관법

Search Result 26, Processing Time 0.021 seconds

The effects of PM driving direction and alert sound type on risk perception and awareness of PM driver of pedestrians (개인형 이동장치(PM)의 주행 방향과 경고방식의 차이가 보행자의 위험 지각과 주행자에 대한 인식에 미치는 영향)

  • Jung, Yoon-Hyun;Lee, Soo-Ji;Kang, Hyunmin
    • Journal of Digital Convergence
    • /
    • v.19 no.7
    • /
    • pp.217-226
    • /
    • 2021
  • The use of personal mobility(PM) is increasing because of preading shared mobility, but, it causes risk of accidents and fear to pedestrians because of lack of sound. The purpose of this study is to find out the effects of the alert sound in PM and driving direction on risk perception of pedestrians, awareness on PM driver, and allowance for driving on each road. The 8 videos were produced from a pedestrian perspective, depending on the alert sound type(silent, vess, bell, voice) and direction of driving(front, back). After watching each video, participants completed surveys. There was a non-effect on the driving direction. Regardless of the alert sound type, all of the sounds reduced the risk perception. Also, the awareness of PM drivers and allowance for driving on each road were positive. This study found that PM needed an alert sound for pedestrian safety. We expect the results of the study to help improve awareness of PM and make policies and regulations.

Edge-Enhanced Error Diffusion Halftoning using Local mean and Spatial Activity (국부 평균과 공간 활성도를 이용한 에지 강조 오차확산법)

  • Kwak Nae-Joung;Kwon Dong-Jin;Kim Young-Gil;Ahn Jae-Hyeong
    • The KIPS Transactions:PartB
    • /
    • v.13B no.2 s.105
    • /
    • pp.77-82
    • /
    • 2006
  • Digital halftoning is the technique to obtain a bilevel-toned image from continuous-toned image. Among halftoning methods, the error diffusion method gives better subjective quality than other halftoning ones. But it also makes edges of objects blurred. To overcome the defect, we proposes the modified error diffusion to enhance the edges using the property that human vision perceives the local average luminance and doesn't perceive a little variation of the spatial variation. The proposed method computes a spatialactivity, which is the difference between a pixel luminance and the average of its $3{\times}3$ neighborhood pixels' Iuminance weighted according to the spatial positioning. The system also usesof edge enhancement (IEE), which is computed from the normalized spatial activitymultiplied by the average luminance. The IEE is added to the quantizer's input pixel and feeds into the halftoning quantizer. The quantizer produces the halftone image having the enhanced edge. The computer experimental results show that the proposed method produces clearer bilevel-toned images than conventional methodsand the edge of objects is preserved well. Also the performance of the preposed method is improved, compared with that of the conventional method by measuring the edge correlation and the local average accordance at some ranges of viewing distance.

Performance Characteristic of a CsI(Tl) Flat Panel Detector Radiography System (CsI(TI) Indirect Flat Panel Detector의 선질에 따른 물리적 영상 평가)

  • Jeong, Hoi-Woun;Min, Jung-Hwan;Kim, Jung-Min;Park, Min-Seok;Lee, Gaung-Young
    • Journal of radiological science and technology
    • /
    • v.35 no.2
    • /
    • pp.109-117
    • /
    • 2012
  • The purpose of this work was to evaluate an amorphous silicon cesium iodide based indirect flat-panel detector (FPD) in terms of their modulation transfer function (MTF), Wiener spectrum (WS, or noise power spectrum, NPS), and detective quantum efficiency (DQE). Measurements were made on flat-panel detector using the International Electrotechnical Commission (IEC) defined RQA3, RQA5, RQA7, and RQA9 radiographic technique. The MTFs of the systems were measured using an edge method. The WS(NPS) of the systems were determined for a range of exposure levels by two-dimensional (2D). Fourier analysis of uniformly exposed radiographs. The DQEs were assessed from the measured MTF, WS(NPS), exposure, and estimated ideal signal-to-noise ratios. Characteristic curve in the RQA3 showed difference in the characteristic curve from RQA5, RQA7, RQA9. MTFs were not differences according to x-ray beam quality. WS(NPS) was reduced with increasing dose, and RQA 3, RQA5, RQA7, RQA9 as the order is reduced. DQE represented the best in the 1mR, RQA 3, RQA5, RQA7, RQA9 decrease in the order. The physical imaging characteristics of FPD may also differ from input beam quality. This study gives an initial motivation that the physical imaging characteristics of FPD is an important issue for the right use of digital radiography system.

Aerosol-extinction Retrieval Method at Three Effective RGB Wavelengths Using a Commercial Digital Camera (상용 디지털 카메라를 이용한 3가지 유효 RGB 파장에서의 미세먼지 소산계수 산출법)

  • Park, Sunho;Kim, Dukhyeon
    • Korean Journal of Optics and Photonics
    • /
    • v.31 no.2
    • /
    • pp.71-80
    • /
    • 2020
  • In this article, we suggest a new method for measuring an aerosol's extinction coefficient using a commercial camera. For a given image, we choose three pixel-points that are imaged for the same kinds of objects located in similar directions. We suggest and calculate aerosol extinction coefficients from these RGB gray levels and the different distances of the three objects. To compare our measurement results, we also measure extinction coefficients using lidar. Finally, we find that there are meaningful and sensible correlations between these two measurements, with a correlation coefficient of 0.86. We measure the aerosol extinction coefficient at three different RGB wavelengths using the same method. From these aerosol extinction coefficients at three different wavelengths, we find that the Angstrom exponent ranges from 0.7 to 1.6 over a full daytime period. We believe that these Angstrom exponents can give important information about the size of the fine particles.

Application Analysis of Digital Photogrammetry and Optical Scanning Technique for Cultural Heritages Restoration (문화재 원형복원을 위한 수치사진측량과 광학스캐닝기법의 응용분석)

  • Han, Seung Hee;Bae, Yeon Soung;Bae, Sang Ho
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.5D
    • /
    • pp.869-876
    • /
    • 2006
  • In the case of earthenware cultural heritages that are found in the form of fragments, the major task is quick and precise restoration. The existing method, which follows the rule of trial and error, is not only greatly time consuming but also lacked precision. If this job could be done by three dimensional scanning, matching up pieces could be done with remarkable efficiency. In this study, the original earthenware was modeled through three-dimensional pattern scanning and photogrammetry, and each of the fragments were scanned and modeled. In order to obtain images from the photogrammetry, we calibrated and used a Canon EOS 1DS real size camera. We analyzed the relationship among the sections of the formed model, efficiently compounded them, and analyzed the errors through residual and color error map. Also, we built a web-based three-dimensional simulation environment centering around the users, for the virtual museum.

The Position for Measuring BMD of the Distal Radius and The Study of the Correlation Between the Distal Radius and Lumba (원위 요골 골밀도의 측정 자세 및 요추 골밀도의 상관관계에 관한 연구)

  • Han, Man-Seok;Jeon, Chul-Min;Kim, Jong-Jin;Seo, Seon-Youl;Kim, Yong-Kyun
    • Journal of radiological science and technology
    • /
    • v.33 no.1
    • /
    • pp.19-24
    • /
    • 2010
  • The aim of this study was to evaluate the change of bone mineral density according to distal radius rotation and the correlations of the lowest BMD measured by DXA at the lumba versus distal radius. The eleven males were projected distal radius by DR X-ray and the measurement of BMD by DXA of the appropriate position of the forearm were performed on 21 males. The healthy 11 and 21 volunteers without any history of operations, anomalies, or trauma were enrolled. The experiment was performed by two methods. First, The DR X-ray was measured distal radius of 11 males in pronation and supination with three, six and nine degrees, including a neutral position. The ROI was measured by the m-view program on the PACS monitor. Second, The DXA was measured distal radius of 21 males in pronation and supination with five and ten degrees, including a neutral position to evaluate the changes of BMD according to the rotation. A correlation of the BMD in the distal radius with BMD that lumbar spine was performed, along with analysis of the data by SPSS 12.0v. The mean rotation angle of the distal radius about eleven males DR X-ray measured $7^{\circ}$ of pronation (82%, n = 9), $6^{\circ}$ of supination and $0^{\circ}$ of neutral of (9%, n = 1), The total average rotation angle in 11 male was $5.1^{\circ}$ of pronation. The rotation angle of the distal radius about twenty one males on DXA measured $7.2^{\circ}$ of pronation (43%, n = 9), $7^{\circ}$ of supination (24%, n = 5), and $0^{\circ}$ of neutral (33%, n = 7), The total average rotation angle in 21 people was $4.1^{\circ}$ of pronation. The correlation of the analysis of lumba and distal radius were r = 3.0, p = 0.18. consequently, The correlation was not significance. Because BMD of lumba was not coverd for BMD of the distal radius, with a neutral position, Pronation is needed for BMD in the distal radius with the rotation angle measuring at the lowest BMD. the rotation angle about five degrees of pronation of the distal radius is recommended.