• Title/Summary/Keyword: 디스크 파손

Search Result 25, Processing Time 0.027 seconds

Mechanical Strength Experiment of Carbon/Carbon Composite for Aircraft Brake Disk (탄소/탄소 브레이크 디스크의 기계적 강도 시험에 관한 연구)

  • 유재석;오세희;김천곤;홍창선;윤병일;김광수
    • Composites Research
    • /
    • v.13 no.6
    • /
    • pp.55-62
    • /
    • 2000
  • The strength test was done for the Carbon/Carbon rotor disk which is the critical part of a carbon/carbon brake system in an operating time. The loading fixture was designed for the static strength test of a single carbon/carbon brake disk using finite element analysis. To simulate the real dynamic system in a static condition, the friction surface of the rotor disk was fixed and static load was applied to the rotor slot in the circumferential direction. The described failure mechanism of the brake disk can be described as matrix cracking occurred first at the contact surface of the rotor slot, subsequent delamination from the cracked contact surface, and the final fracture at the notch of the rotor.

  • PDF

Surface Damage Mechanism of Hard Disk (하드디스크의 표면 파손 기구에 관한 고찰)

  • 정구현;김대은;김상국
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1996.11a
    • /
    • pp.716-720
    • /
    • 1996
  • In this work the surface damage mechanism of hard disk was investigated. Experiments were peformed to simulate the contact during start and stop. Evidence of significant surface damage appeared after 20,000 cycles. It was found that despite higher hardness, the slider showed more signs of damage than the disk. Optical microscopy showed that the surface was damaged by abrasive action as well as adhesion of wear debris.

  • PDF

Study on the Fracture of Automotive Clutch Disk due to Abnormal Vibration (자동차 클러치 디스크의 불규칙 진동에 의한 디스크 파손 연구)

  • Cho, Chong-Du;Lee, Heung-Shik
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.11a
    • /
    • pp.556-561
    • /
    • 2006
  • In this study, the failure of the automotive clutch disk was investigated. During the process of power transmission, clutch disk plates did repeated work of releasing and engaging the pressure plate. The effects of unbalance rotation in the abnormal vibration and torque amplitude under engaged state were measured from this experiment. In order to reduce the unbalance, a modified clutch disk shape was developed. With a three-dimensional model of the stopper pin, to predict fatigue fracture, finite element analysis was carried out and evaluated the improvement of the new clutch disk.

  • PDF

Surface Failure Phenomenon Due to Head/Disk Contact (헤드/디스크의 접촉으로 인한 표면파손 현상)

  • Chung, Koo-Hyun;Moon, Jae-Taek;Lee, Jung-Kyu;Kim, Dae-Eun
    • Proceedings of the KSME Conference
    • /
    • 2001.06c
    • /
    • pp.322-326
    • /
    • 2001
  • Hard disk drive(HDD) consists of a head/slider system which flies over the magnetic disk at an extremely low height. As the density of HDD increases the flying height of the head needs to be decreased. This increases the chance for contact between the slider and the disk. This paper addresses some key issues related to surface failure characteristics of HDD. It is shown that flying behavior of the slider during contact-start-stop cycle can be analyzed based on different regimes of air film lubrication, experimental methods for identifying the underlying mechanisms and improving the reliability of HDD are discussed.

  • PDF

Relationship between Hard Disk Surface Damage and Data Loss (하드디스크의 표면파손과 데이터 손실과의 관계)

  • 이성창;박용식;전규찬;김대은
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.17 no.2
    • /
    • pp.35-42
    • /
    • 2000
  • In recent years the recording density of hard disks has increased significantly largely due to the decreasing flying height. As a result of decreased flying height, the reliability issue become more critical. In this work the relationship between hard disk surface damage and data loss was investigated by using an actual hard disk drive. The purpose of this research was to identify the key factor which leads to data loss. It was shown that data loss is directly related to the physical damage of the Co-magnetic layer and there was no data loss when only carbon protective coating was damaged by the diamond tip.

  • PDF

Analysis of Damaged Instance and Forming Fault for Disc Part in Automotive Steel Wheel (자동차용 스틸휠 디스크부품의 성형불량 및 파손사례분석)

  • Lee, Sung-Hee;Kim, M.Y.;Kim, T.G.;Yun, H.Y.;Kang, S.W.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2006.05a
    • /
    • pp.234-238
    • /
    • 2006
  • In this research, an analysis of damaged instance and forming fault for disc part in automotive steel wheel was performed. Rolled steel material, which had been used in the manufacturing of the damaged disc part, was prepared for tensile test, quantitative analysis of chemical component and acquirement of scanning electron microscope images. Although the results of mechanical properties and chemical component ratio for the material satisfied the suggested specification, some material inherent problem was found in the scanning electron microscope images. Finally, in an analysis of chemical component for the damaged disc part used in road condition, mismatching of chemical component ratio between the suggested specification and test result was found.

  • PDF

Influence of the variation of its geometry on the disk failure (디스크 형상 변화에 따른 파손에 끼치는 영향)

  • Kim, Jong-Man;Hwang, Hyo-Kune;Dan, Byung-Ju;Kim, Wae-Yeul;Lee, Jin-Woo
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.31-35
    • /
    • 2004
  • The speed competition of optical disk drive has been accelerated with the fast advancement of its storage density and data transmission technology. The continuous increase of the spinning speed of CD meets the unexpected and catastrophic failure of disk during the operation. The effect of its thickness and outer radius of disk were investigated to reduce stresses and J-integral around the crack tip. The effect of its thickness was considered ahead of the crack tip. In the effect of outer radius of disk, linear elastic fracture mechanics was used to obtain the critical crack length, which indicates the onset length for unstable crack growth. This approach is so significant as to detect the growing crack by disk drive before the catastrophic failure, which will provide the standard size of its safety for high-speed disk drive.

  • PDF

A Study on the Surface Damage between Head/Disk Interfaces by Using AFM (AFM을 이용한 Head/Disk의 표면 파손에 관한 고찰)

  • 이성창;정구현;김대은
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.15 no.9
    • /
    • pp.167-174
    • /
    • 1998
  • In this work the surface damage of head and disk of a hard disk drive was analysed using an Atomic Force Microscope. The initial damage of the disk occurred by generation of extremely small wear particles. Also it was shown that wear particles tend to pile up near the front side of the slider. The surface damage mechanism of drag test and contact-start-stop test was found to be quite similar.

  • PDF

Development of Nondestructive System for Detecting the Cracks in KTX Brake Disk Using Rayleigh Wave (Rayleigh Wave를 이용한 KTX 제동 디스크의 균열 검측 시스템 개발)

  • Kim, Min Soo;Yeom, Yun Taek;Park, Jin-Hyun;Song, Sung Jing;Kim, Hak Joon;Kwon, Sung Duck;Lee, Ho Yong
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.37 no.1
    • /
    • pp.29-36
    • /
    • 2017
  • Recently, KTX (Korean Train Express) train stoppage accidents were mainly caused by malfunctioning equipment, aging and cracking of railway vehicles, crack breakages of brake disks, and breakages of brake disks. Breakage of brake disk can cause large-scale casualties such as high-speed collision and concern about derailment by hitting lower axle and wheel. Therefore, in this study, a brake disk with solid and ventilation type, which is the brake disk of a KTX train was modeled, and a dynamometer system was constructed to operate the disk. A Rayleigh wave was used to inspect the surface of the brake disk. An ultrasonic inspection module was developed for the brake disk by using a local immersion method due to the difficulty involved in ultrasonic inspection using an existing immersion method. In addition, the surface defects of the brake disk were evaluated using a dynamometer mock-up system and an ultrasonic inspection module of the brake disk.

The T-tree index recovery for distributed main-memory database systems in ATM switching systems (ATM 교환기용 분산 주기억장치 상주 데이터베이스 시스템에서의 T-tree 색인 구조의 회복 기법)

  • 이승선;조완섭;윤용익
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.22 no.9
    • /
    • pp.1867-1879
    • /
    • 1997
  • DREAM-S is a distributed main-memory database system for the real-time processing of shared operational datra in ATM switching systems. DREAM-S has a client-server architecture in which only the server has the diskstorage, and provides the T-Tree index structure for efficient accesses to the data. We propose a recovery technique for the T-Tree index structre in DREAM-S. Although main-memory database system offer efficient access performance, the database int he main-memory may be broken when system failure such as database transaction failure or power failure occurs. Therfore, a recovery technique that recovers the database (including index structures) is essential for fault tolerant ATM switching systems. Proposed recovery technique relieves the bottleneck of the server processors disk operations by maintaining the T-Tree index structure only in the main-memory. In addition, fast recovery is guaranteed even in large number of client systems since the T-Tree index structure(s) in each system can be recovered cncurrently.

  • PDF