• Title/Summary/Keyword: 등가 임피던스

Search Result 244, Processing Time 0.025 seconds

Method of deriving the acoustic impedance and sound absorption coefficient of materials by manipulating electrical impedance of a loudspeaker (스피커의 전기적 임피던스를 이용한 시료의 음향임피던스와 흡음계수 도출 기법)

  • Doo, Sejin
    • The Journal of the Acoustical Society of Korea
    • /
    • v.40 no.3
    • /
    • pp.254-260
    • /
    • 2021
  • When measuring the sound absorption coefficient of a specimen, a reverberation room which is costly or an impedance tube which has limitations in measuring low frequencies have been engaged. In this paper, a new measurement method of acoustic impedance or sound absorption coefficient has been suggested, which does not need microphones and only uses electrical impedance measurement data and derived Thiele/Small parameters of a speaker. The theory of this method has been described using equivalent circuit of the loudspeaker and acoustic properties of a test specimen are measured to demonstrate the validity of this method. It was confirmed that this method can easily measure the sound absorption coefficient in the low frequency band, which was previously difficult to trust. The advantages, limitations, and applicability of this method are discussed.

Bioelectrical Impedance Analysis of Multi-frequency using Portable Small Impedance Measuring System (휴대용 소형임피던스 측정시스템을 이용한 다중주파수의 생체임피던스 해석)

  • Kim, Min Soo;Cho, Young Chang
    • Journal of the Korea Convergence Society
    • /
    • v.8 no.2
    • /
    • pp.121-126
    • /
    • 2017
  • In this study, we measured the bioelectrical impedance of whole body in various frequency bands by non-invasive method by four electrode method using a portable small impedance measurement system developed to understand the bioimpedance characteristics of intracellular fluid and extracellular fluid components through a skin equivalent model. The measurements were performed on 10 male subjects (mean age $24{\pm}3.0$, body mass index(BMI) $20.3kg/m^2$) for four weeks and the bioimpedances were measured at multi-frequencies (1 kHz, 5 kHz, 50 kHz, 70 kHz, 100 kHz and 500 kHz). Experimental results show that the impedance is the highest in the low frequency range of 1 kHz and the lowest in the high frequency range of 500 MHz. Especially, it was confirmed through experiments that the impedance is rapidly lowered above 50 kHz band. In addition, it was confirmed that similar characteristics to the measured values of the bioimpedance measuring system were obtained in the simulations for understanding the impedance characteristics of the intracellular fluid and the extracellular fluid through the skin equivalent circuit model.

Electrochemical Impedance Analysis of Polyaniline-Film on Platinum Electrodes (백금 전극에 입힌 폴리아닐린의 전기화학적 임피던스)

  • Chon, Jung-Kyoon;Min, Byoung Hoon
    • Journal of the Korean Chemical Society
    • /
    • v.39 no.9
    • /
    • pp.722-727
    • /
    • 1995
  • The electrochemical impedance spectra of polyaniline film prepared by cyclic voltammetry have been investigated in 0.1 M aqueous sulfuric acid solution. Charge transfer resistances were rather low at the oxidized states in agreement with the conductive behavior reported at these potentials. The corresponding exchange current densities were very high. Large values of capacitance associated with the polymer have been found which vary as a function of the electrode potentials. An equivalent electrical circuit has been deduced from the impedance data. It was therefore possible to obtain the parameters of the ionic mass transport within the film.

  • PDF

The Impedance Modeling of the Lithium Battery for BESS (BESS용 리튬 배터리의 임피던스 모델링)

  • Lee, Jong-Hak;Kim, Soo-Hong;Kim, Tae-Hyeong;Kim, Sang-Hyun;Kwon, Byeong-Ki
    • Proceedings of the KIPE Conference
    • /
    • 2011.07a
    • /
    • pp.109-110
    • /
    • 2011
  • 본 논문은 배터리 에너지 저장 시스템(Battery Energy Storage System, BESS)에 사용된 대용량 리튬이온 배터리의 등가 모델링을 제안하였다. 리튬 배터리의 전기화학적 특성을 고려한 임피던스 등가모델을 선정한 후 등가모델의 파라미터를 추출하였으며, 추출된 파라미터와 SOC(State-of Charge)와의 관계를 살펴보았다. 본 연구를 통하여 얻어진 파라미터를 이용하면 BESS 제어시 배터리 특성을 파악할 수 있으므로, 배터리의 최적제어 및 시스템의 신뢰성을 높일 수 있을 것으로 기대된다.

  • PDF

Design Analysis of Impedance Matching Circuit by Phasor Plot (페이저도에 의한 임피던스 정합회로 설계 해석)

  • Weon, La-Kyoung
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.26 no.11
    • /
    • pp.1686-1696
    • /
    • 2022
  • The impedance matching circuit design technique based on the phasor plot introduced in this paper is based on the impedance triangle of electric circuit. It is a technique that designs through the construction of a phasor figure using the values given to the matching circuit design. The design pattern is based on L-type, inverted L-type, T-type, and 𝜋-type, and unknown reactance elements are determined through phasor shapes. In this paper, using a design by phasor plot, we design several cases, such as the case where the input and output ports are pure resistance and have reactance. It was confirmed that the design value was verified by serial-parallel equivalent conversion to achieve matching. This design technique can immediately grasp the phase or size of input/output power, so it is expected to be applied mainly in a low frequency band due to rapid design change and application.

Improvement of connector performance using analysis of characteristic impedance (특성임피던스 분석을 사용한 커넥터 성능향상)

  • Yang, Jeong-Kyu;Kim, Mun-Jung
    • Proceedings of the KAIS Fall Conference
    • /
    • 2010.05a
    • /
    • pp.71-73
    • /
    • 2010
  • 본 논문에서는 커넥터의 S-파라미터로 특성임피던스를 계산하고 커넥터의 성능개선을 위해 설계변경을 한다. FEM(Finite Elements Method) 시뮬레이터로 커넥터의 S-파라미터를 계산하고 회로 시뮬레이터에서 동일한 R, L, C 값을 가지는 등가 회로모델을 추출한다. 인덕턴스와 커패시턴스로 특성임피던스를 계산하고 임피던스 부정합 상태를 확인한다. 특성임피던스 공식으로부터 커패시턴스를 증가시켜 임피던스 정합을 유도하고 커패시턴스는 신호선의 평행한 면적을 확장하여 증가시킨다. 결과적으로 반사손실이 약 5 dB 개선되었고 신호선 유효면적의 증가로 임피던스가 감소하여 삽입손실도 개선되었다.

  • PDF

Impedance spectroscopy depending on voltage in organic light-emitting diodes (유기발광소자의 전압의존성에 따른 임피던스 분석)

  • Ahn, Joon-Ho;Lee, Joon-Ung;Lee, Won-Jae;Lee, Sung-Ill;Song, Min-Jong;Kim, Tae-Wan
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.07a
    • /
    • pp.481-482
    • /
    • 2005
  • 유기발광소자의 발광층의 전압에 따른 임피던스의 변화를 살펴보았다. 임피던스는 전압의 변화에 따른 의존성을 보이며, 그에 따른 임피던스와 Cole-Cole 반원의 변화를 전기전도기구와 비교하여 살펴보았다. 소자의 구조는 ITO/$Alq_3$/Al의 구조로 발광층의 두께는 60 nm로 열증착하여 실험하였다. 실험에서 전기전도기구의 Ohmic 영역, SCLC 영역, 부성저항영역, TCLC 영역에서 각각 임피던스를 측정하였고, 전압의 증가에 따라 임피던스의 크기가 감소하고, 위상각은 0V에서 용량성을 보이다가 발광영역에서 저항성을 나타내는 것을 알 수 있었다. 또한 전압에 따른 Cole-Cole 반원을 살며보면 전압이 증가할수록 반원의 크기가 감소하는 것을 알 수 있으며, 이를 통해 간단한 등가회로를 예측할 수 있었다.

  • PDF

Calculation of Radiation Impedance in Consideration of Acoustic window (음향윈도우 영향을 고려한 방사임피던스의 계산)

  • Kim JungSoon;Kim MooJoon;Kim ChunDuck;Ha KangLyeol
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • autumn
    • /
    • pp.451-452
    • /
    • 2004
  • 본 연구에서는 방사임피던스의 계산에 있어서, 음향윈도우의 물질상수 및 두께의 변화에 따른 영향을 고려하였다. 전송 선로형 등가회로를 방사면과 음향 매질 사이에 삽입함으로써 방사면에서 본 자기 방사임피던스의 변화를 평면 및 곡면 배플에 대하여 계산하고 그 결과를 고찰하였다.

  • PDF

Grid Impedance Estimation Method Using Negative Sequence Current Injection (역상분 전류 주입을 이용한 계통 등가 임피던스 추정 기법)

  • Park, Chan-sol;Song, Seung-Ho;Im, Ji-Hoon
    • Proceedings of the KIPE Conference
    • /
    • 2015.07a
    • /
    • pp.526-527
    • /
    • 2015
  • 본 논문은 계통에 전력을 변동하여 계통 임피던스를 추정하는 기법의 문제점을 분석하고 개선된 역상분 전류 주입을 이용한 임피던스 추정 기법을 제안한다. 기존의 계통 임피던스 추정 기법에서는 유, 무효 전력의 크기를 변화시키고, 그에 따른 두동작점에서 측정된 전압의 변동량을 통해 계통 임피던스를 계산한다. 하지만 일반적인 계통 연계형 인버터에는 전원 전압의 위상을 추종하는 PLL이 동작하고 있으며, 이 PLL은 정상 상태에서 얻을 수 있는 전류 주입에 따라 발생하는 d-q축 전압의 변동량을 왜곡시켜 추정 오차를 유발한다. 따라서 본 논문에서는 불평형 전원을 독립적으로 제어하는 듀얼 제어기와 정상분 PLL 기법을 사용하여 역상분 전류에 의한 역상분전압의 변동량만으로 PLL에 의한 PCC 전압의 정상 상태 측정 오차를 제거하여 계통 임피던스를 정확히 추정하는 기법을 제안한다.

  • PDF

Impedance Characteristics of Overhead Medium-Voltage Power lines for Power Line Communication (전력선통신을 위한 고압 배전선로의 임피던스 특성)

  • Chun Dong-wan;Park Young-jin;Kim Kwan-ho;Shin Chull-chai
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.42 no.11
    • /
    • pp.67-78
    • /
    • 2005
  • In this paper, impedance characteristics of overhead medium-voltage (MV) power line for power line communication (PLC) is analyzed. For analysis, a two-port equivalent network model of MV power lines is derived. By applying the equivalent model and basic transmission line theory, input impedance at the signal induction part is calculated. And also calculated input impedance of power line itself that the medium voltage coupler and coaxial cable effect are removed. For verification, impedance of power lines is measured at a test field for an MV PLC. The results show that impedance of MV power line itself is between $200\;{\Omega}\;and\;300\;{\Omega}$ and converges to a half of their characteristic impedance with increasing frequency. And also measured data is very similar to calculated data.