Evaluation of Equivalent-Static Floor Acceleration for Seismic Design of Non-Structural Elements (비구조요소의 내진설계를 위한 등가정적 층가속도 평가)

  • Jun, Su-Chan;Lee, Cheol-Ho;Bae, Chang-Jun;Kim, Sung-Yong
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.36 no.3
    • /
    • pp.121-128
    • /
    • 2020
  • In this paper, the ASCE 7 equivalent static approach for seismic design of non-structural elements is critically evaluated based on the measured floor acceleration data, theory of structural dynamics, and linear/nonlinear dynamic analysis of three-dimensional building models. The analysis of this study on the up-to-date database of the instrumented buildings in California clearly reveals that the measured database does not well corroborate the magnitude and the profile of the floor acceleration as proposed by ASCE 7. The basic flaws in the equivalent static approach are illustrated using elementary structural dynamics. Based on the linear and nonlinear dynamic analyses of three-dimensional case study buildings, it is shown that the magnitude and distribution of the PFA (peak floor acceleration) can significantly be affected by the supporting structural characteristics such as fundamental period, higher modes, structural nonlinearity, and torsional irregularity. In general, the equivalent static approach yields more conservative acceleration demand as building period becomes longer, and the PFA distribution in long-period buildings tend to become constant along the building height due to the higher mode effect. Structural nonlinearity was generally shown to reduce floor acceleration because of its period-lengthening effect. Torsional floor amplification as high as 250% was observed in the building model of significant torsional irregularity, indicating the need for inclusion of the torsional amplification to the equivalent static approach when building torsion is severe. All these results lead to the conclusion that, if permitted, dynamic methods which can account for supporting structural characteristics, should be preferred for rational seismic design of non-structural elements.

The Design Eccentricity for Torsionally Unbalanced Structure (비틀림 거동을 하는 구조물의 설계 편심)

  • 조소훈;이명규
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.5 no.5
    • /
    • pp.63-72
    • /
    • 2001
  • In this paper, to satisfy the safety and economy immediately, we assume the center of lateral load in case the dynamic motion of the torsionally unbalanced structure is transformed into the static lateral load using modal analysis and proposes a method to control the design eccentricity in order to make the center of lateral load coincide with the center of strength. And when the structure is designed by proposed method, it is shown that the structure designed by proposed method does not demand excessive additional ductility in comparison with the structure designed by provisions of other seismic building code.

  • PDF

Estimation of Interstory Drift for Moment Resisting Reinforced Concrete Frames Using Equivalent SDOF System (등가 1자유도계를 이용한 철근콘크리트 골조건물의 층간변위 응답 산정)

  • Kang, Ho-Geun;Jun, Dae-Han
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.8 no.5 s.39
    • /
    • pp.25-33
    • /
    • 2004
  • To evaluate the seismic capacity of a multistorey building structures in performance based seismic design, it is needed to convert MDOF model into equivalent SDOF model. This paper presents predictions for interstory drift of multistorey structures using method of converting a MDOF system into an equivalent SDOF model. The principal objective of this investigation is to evaluate appropriateness of converting method through performing nonlinear time history analysis of a multistory building structures and an equivalent SDOF model. Comparing the interstory drift of multistorey structures calculated by time history analysis and those evaluated by an equivalent SDOF model, the adequacy and the validity of converting method is verified. The conclusion of this study is following; A method of converting a MDOF system into an equivalent SDOF model through the nonlinear time history response analysis is valid. Inelastic first mode shapes are expected to be more accurate than elastic first mode shapes in obtaining interstory drift of multistorey structures from equivalent SDOF model.

Structural Integrity Evaluation of Nuclear Seismic Category IIA 2" Globe Valve for Seismic Loads (지진하중을 받는 원자력 내진등급 2A 글로브 밸브의 구조 건전성 평가)

  • Chung, Chul-Sup
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.9 no.6
    • /
    • pp.1500-1505
    • /
    • 2008
  • To evaluate the structural integrity of the nuclear seismic category IIA bellows seal 2" globe valve under the seismic service conditions the seismic analysis was performed in accordance with ASME, section III, ND-3500, 1989 edition. The finite element computer program, ANSYS, Version 10.0, is used to perform both a mode frequency analysis and an equivalent static seismic analysis of the valve assembly. The mode frequency analysis results show the fundamental natural frequency is greater than 33 Hz and does not exist in seismic range, thus justifying the use of the static analysis. The stresses resulted from various loadings and their combinations are within the allowable limits specified in the above mentioned ASME code. The results of the seismic evaluation fully satisfied the structural acceptance criteria of the ASME code. Accordingly the structural integrity on the globe valve was proved.

Effect of Nonlinear Analysis Procedures for Seismic Responses of Reinforced Concrete Wall Structure (철근콘크리트 벽체구조물의 지진응답에 대한 비선형 해석기법의 영향)

  • Song, Jong-Keol;Jang, Dong-Hui;Chung, Yeong-Hwa
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.4A
    • /
    • pp.659-675
    • /
    • 2006
  • Recently, significant progress has been made in performance-based engineering methods that rely mainly on nonlinear static seismic analysis procedures. The Capacity Spectrum Method (CSM) and the Displacement Coefficient Method (DCM) are the representative nonlinear static seismic analysis procedures. In order to evaluate the applicability of the procedures to the seismic evaluation and design process of new and existing structures, the accuracy of both CSM and DCM should be evaluated in advance. The accuracy of seismic responses by the nonlinear static procedures is evaluated in comparison with the shaking table test results for the structural wall specimen subjected to the far field and near field earthquakes. Also conducted are comparative studies where the shaking table test results are compared with those from nonlinear dynamic analysis procedures, i.e., Single-Degree-of-Freedom (SDOF), equivalent SDOF and Multi-Degree-of-Freedom (MDOF) systems.

Evaluation of Seismic Performance of Mixed Building Structures by using the Nonlinear Displacement Mode Method (비선형 변위모드법을 적용한 복합구조물의 내진성능평가)

  • 김부식;송호산
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.7 no.6
    • /
    • pp.71-80
    • /
    • 2003
  • Though a nonlinear time history analysis may be provided to estimate more exactly the seismic performance of building structure, approximation methods are still needed in the aspect of practicality and simplicity, In converting a multi-story structure to an equivalent SDOF system, the mode vectors of the multi-story structure are assumed as the mode shape in elastic state regardless of elastic or elastic-plastic state. However, the characteristics of displacement mode are also changed after the yielding made in the structural elements, because the structure becomes inelastic in each incremental load step. In this research, a method of converting MDOF system to ESDOF system is presented by using nonlinear displacement mode considering the mode change of structures after the yielding. Also, the accuracy and efficiency of the method of the nonlinear displacement mode method of the estimate of seismic response of Mixed Building Structures were examined by comparing the displacements of the roof level of the multi-story building structures estimated from this converted displacement response of ESDOF with the displacement of the roof level through the nonlinear dynamic analysis of the multi-story building structures subjected to an actual earthquake excitation.

Dynamic Response Optimization of a Mobile Harbor Crane with a Moving Support (지지부가 움직이는 모바일하버용 크레인의 동적 응답 최적설계)

  • Kim, Hyun-Bum;Lee, Jae-Jun;Jang, Hwan-Hak;Park, Gyung-Jin
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.36 no.5
    • /
    • pp.497-504
    • /
    • 2012
  • The mobile harbor is a new innovative system that delivers containers from a containership to a harbor without good infrastructure. A crane is installed on the deck of the mobile harbor and transfers the containers. The structure of the crane is influenced by the inertia force that occurs from a moving support. Thus an accurate safety verification considering the moving support is required. Lightweight of the crane structure is also significant in the design for low production cost and efficient operation. Dynamic response optimization can be exploited to achieve these two requirements. Equivalent static loads method is employed for dynamic response optimization of the crane. The equivalent static loads method transforms dynamic loads to equivalent static loads, and static response structural optimization with the transformed equivalent static loads are solved. The process proceeds in a cyclic manner. A new method is proposed to consider the moving supports and the structure of the mobile harbor is optimized using the proposed method.

Improved Modal Pushover Analysis of Multi-span Continuous Bridge Structures (다경간 연속 교량 구조물의 지진응답 평가를 위한 개선된 모드별 비탄성 정적 해석법에 관한 연구)

  • Kwak, Hyo-Gyoung;Hong, Seong Jin;Kim, Young Sang
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.3A
    • /
    • pp.497-512
    • /
    • 2006
  • In this paper, a simple but effective analysis procedure to estimate seismic capacities of multi-span continuous bridge structures is proposed on the basis of modal pushover analysis considering all the dynamic modes of structure. Unlike previous studies, the proposed method eliminates the coupling effects induced from the direct application of modal decomposition by introducing an identical stiffness ratio and an approximate elastic deformed shape. Moreover, in addition to these two introductions, the use of an appropriate distributed load {P} makes it possible to predict the dynamic responses for all kinds of bridge structures through a simpler analysis procedure. Finally, in order to establish the validity and applicability of the proposed method, correlation studies between rigorous nonlinear time history analysis and the proposed method are conducted for multi-span continuous bridges.

A Parametric Study on Tensile Stress of a Hybrid Floating Structure System (매개변수 연구를 통한 하이브리드형 부유식 구조물의 인장응력 발생 분석)

  • Zi, Goangseup;Lee, Seung-Jung;Kwak, Yeon-Min;Jeong, Youn
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.32 no.5B
    • /
    • pp.313-320
    • /
    • 2012
  • A hybrid floating structure system combined with pontoon and semi-submersible type modules is proposed. This new system can reduce tensile forces of bottom slabs which could cause fatal damage of concrete floating structures. We performed a parametric study on the dimensions of this new system and investigate the sensitivity of the parameters to the behavior. In order to investigate various cases efficiently, we developed a simple two-step static analysis method for the fluid-structure interaction. An optimum system is derived from the investigation of the analysis results, weights and drafts of the hybrid structure. This study shows that introducing this new system to concrete floating structures is an effective way to reduce the tensile force of the bottm slab of such a floating structure. Also, it was found that when the length of the semi-submersible module is about 15%, the behavior would be optimal in the considered case.

Analysis of Vibration-Noise Characteristics of a Passenger Car (승용차의 진동 소음 특성 해석)

  • 성명호;이장무;김석현;박동철
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1993.10a
    • /
    • pp.87-92
    • /
    • 1993
  • 본 연구에서는 반연성해석(Semi-coupling analysis) 즉 음향 응답이 구조와 음향 시스템의 모달 계수로 표현되는 방법과 구조-음향 연성계수를 이용한 소음저감의 예를 제시한다. 이전까지의 연성해석에서는 해석의 신뢰성을 위 하여 실험에서 구한 구조 모우드를 사용하였다. 그러나 설계단계에서 차실소 음을 예측하고 설계변경의 자료를 제시하기 위해서는 유한요소법을 이용한 예측이 필수적이다. 본 연구에서는 부분 구조 합성법, 주요 결합부에 상세 유한요소 모델의 정적해석등에 의한 등가모델링 기법, 감도해석을 이용한 결 합부 모델링기법을 이용한 유한요소법 구조모우드해석과 그 결과를 이용한 연성해석의 결과를 보여준다.

  • PDF