• Title/Summary/Keyword: 등가골조 모델

Search Result 24, Processing Time 0.028 seconds

An equivalent model for the seismic analysis of high-rise shear wall apartments (고층 벽식 아파트의 지진해석을 위한 등가모델)

  • Kim, Tae-Wan;Park, Yong-Koo;Kim, Hyun-Jung;Lee, Dong-Guen
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.11 no.5
    • /
    • pp.11-21
    • /
    • 2007
  • Currently in the country, the necessity of seismic analyses is increasing due to the increase of demand and interest in seismic design. Especially, shear wall apartments are constructed mostly for a residental building so seismic analyses for the apartment are actively executed. For the seismic analysis of the shear wall apartment, it may be not efficient in time and effort to model the entire structure by a finite element mesh. Therefore, an equivalent model is needed to simulate the dynamic behavior of the structure by decreasing the number of degrees of freedom. In this study, a method to form an equivalent model that is simple and easy to use was proposed utilizing effective mass coefficient that is highly correlated to mode shape of the structure. This equivalent model was obtained by replacing a shear wall structure with an equivalent frame structure having beams and columns. This model can be used very effectively when excessive seismic analyses are necessary in a short period because it can be operated in any commercial program and reduce the analysis time. Also, it can model floor slabs so it can represent the actual behavior of shear wall apartments. Furthermore, it is very excellent since it can represent the asymmetry of the structure.

Fragility Analysis of RC Moment Resisting Framewith Masonry Infill Walls (비내력벽을 가진 RC모멘트저항골조의 취약도 해석)

  • Ko, Hyun;Park, Yong-Koo;Choi, Byeong-Tae;Kim, Min-Gyun;Lee, Ui-Hyun;Lee, Dong-Guen
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2009.04a
    • /
    • pp.442-445
    • /
    • 2009
  • 지진에 대한 건축물의 확률적 성능평가에 대해서는 지진하중에 대한 건축물의 손상확률 또는 파괴확률을 나타내는 지진취약도 함수를 작성하여 대상 건축물에 대한 지진위험도를 평가하는 방법을 이용하고 있으며 이에 대한 많은 연구가 이루어지고 있다. 본 연구에서는 지진하중과 구조물 재료특성의 불확실성을 고려하고 대상 건축물의 지진취약도 해석을 통하여 비내력벽의 유무에 따른 건축물의 지진거동 및 내진성능을 평가하였다. 비내력벽을 보편화된 모형화 방법인 등가의 대각 압축 스트럿으로 고려하여 비내력벽의 유무에 따른 저층 철근콘크리트 건축물을 모형화하였으며 지진하중의 강도는 유효최대지반가속도를 이용하여 각 건축물에 대하여 지진취약도를 작성하였다. 취약도해석 결과로 연약층을 가지고 있는 건축물의 경우는 손상확률이 골조만 있는 경우보다 크며 동일한 해석모델의 경우에도 해석방법에 따라서 취약도 곡선의 형태가 다름을 알 수 있었다.

  • PDF

Modified Nonlinear Static Pushover Procedures of MDOF Bridgesfor Seismic Performance Evaluation (내진성능평가를 위한 다자유도 교량의 수정 비선형 등가정적해석법)

  • Cho, Chang-Geun;Kim, Young-Sang;Bae, Soo-Ho
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.10 no.4
    • /
    • pp.175-184
    • /
    • 2006
  • Two methods of the nonlinear static pushover analysis have been presented for the performance-based seismic design and evaluation of MDOF continuous bridges. Guidelines for buildings presented in FEMA-273 applying the Displacement Coefficient Method (DCM) and in ATC applying the Capacity Spectrum Method(CSM) have been modified for MDOF bridges. Two methods are compared with the time- history analysis. The lateral load distribution pattern for seismic loads has been examined in the static pushover analysis. The force-based fiber frame finite element has been implemented in the modeling of reinforced concrete piers.

A Study on Forced Vibration Tests on a Structure with Stud Type of Vibration Control Damper (스터드형 진동제어 강재댐퍼가 장착된 3층 강구조 골조의 강제진동실험에 관한 연구)

  • Lee, Seung-Jae
    • Journal of Korean Association for Spatial Structures
    • /
    • v.6 no.2 s.20
    • /
    • pp.115-121
    • /
    • 2006
  • In recent years vibration control damper made of low yield point steel is expected to play an important role in controlling structural vibration induced earthquake and wind. But their dynamic characteristics and energy dissipation effects on the whole structure model are not clarified. In this paper, firstly, we presents the results of cyclic tests on low yield steel dampers. Secondly, forced vibration tests on existence three stories steel structure model with low yield point steel dampers are presented. Lastly, it is estimated energy amount which is dissipated through the hysteresis dampers by using two types of analytical models, hysteresis model and equivalent linear model.

  • PDF

Fragility Analysis of RC Moment Resisting Frame with Masonry Infill Walls (비내력벽을 가진 RC모멘트저항골조의 취약도 해석)

  • Ko, Hyun;Park, Yong-Koo;Lee, Dong-Guen
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.22 no.4
    • /
    • pp.355-362
    • /
    • 2009
  • Many of residential buildings, which have pilotis in lower stories to meet the architectural needs, are recently constructed in Korea. Usually, infill walls located in the upper stories of these buildings may cause a soft first story, which is very weak from the earthquake resistance. In the design of the buildings, the infill walls of upper stories are usually considered as non-structural elements and thus they are not included in the analytical model. However, the infill walls may affect the seismic behavior of the residential buildings. Therefore, the differences in seismic behaviors of RC buildings with and without masonry infill walls are required to be investigated. In this study, seismic fragility analyses were performed for masonry infilled low-rise RC moment-resisting frames. And seismic behaviors of RC moment-resisting frame with/without masonry infill walls were evaluated. Two types of structural system with the same frame and different allocation of infill walls are used to evaluate the influence of masonry infill walls on seismic behavior of RC moment-resisting frames. The infill walls were modeled as bi-equivalent diagonal struts. The fragility analyses show that the seismic performance of RC moment-resisting frames with soft story is below the desirable building seismic performance level recommended by current seismic codes, indicating high vulnerability of RC moment-resisting frames with soft story.

Damping System Design for Apartment Buildings Using Equivalent Frame Model (등가프레임모델을 이용한 공동주택의 감쇠시스템 설계)

  • Kim, Jong-Ho;Lee, Myoung-Kyu;Chun, Young-Soo;Lee, Dong-Chul
    • Journal of the Korea Concrete Institute
    • /
    • v.26 no.3
    • /
    • pp.351-360
    • /
    • 2014
  • The purpose of this research is to introduce the simplified equivalent frame model for the equivalent lateral force procedure, the response spectrum procedure and nonlinear procedure according to ASCE7-10 in order to reduce the time of performance and reasonably evaluate the effect of applying the damping system with the various conditions for the analysis and the variable. In this research, the seismic performance assessment and the design of the damping system were conducted through the nonlinear time history analysis based on the performance based seismic design in ASCE7-10 in regard to applying the damping system to apartment buildings which is lately issued. The optimal design based on the 75% of seismic base shear was performed for an apartment building. The seismic performance assessment were conducted to check the safety of the building, and the economic evaluation was performed by comparing the amount of resource for the optimal designed building with the amount of resource for the original building. In addition, hysteresis dampers was applied to the apartment building, and the suggested equivalent frame model was performed using the damping system design in ASCE7-10, then its control effects were proved in the full scale model of the apartment building which was used in this research.

A Modified Equivalent Frame Model for Flat Plate Slabs Under Combined Lateral and Gravity Loads (조합하중시의 플랫 플레이트 슬래브 시스템에 대한 수정된 등가골조 모델)

  • Oh, Seung-Yong;Park, Young-Mi;Han, Sang-Whan
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.11a
    • /
    • pp.369-372
    • /
    • 2006
  • Flat plate slab systems have been commonly used as a gravity force resisting systems, which should be constructed with lateral force resisting systems such as shear walls and moment resisting frame. ACI 318(2005) allows the Direct design method, the equivalent frame method (ACI-EFM) under gravity loads and the finite-element models, effective beam width models and equivalent frame models under lateral loads. ACI-EFM can be used for gravity loads as well as lateral loads analysis. But the method may not predict the behavior of flat plate slabs under lateral loads. Thus Previous study developed a Modified equivalent frame method(Modified-EFM) which could give more precise answer for flat plate slab under lateral loads. This study is to verified the accuracy of a Modified-EFM under combined lateral and gravity loads. The accuracy of this model is verified by comparing the results using the Modified-EFM with the results of finite element analysis. For this purpose, 7 story building is considered. The analysis results of other existing models are included. The analysis results show that Modified-EFM produces comparable drift and slab internal moments with those obtained from finite element analysis.

  • PDF

Modified Equivalent Frame Models for Flat Plate slabs Under Lateral Load (수평하중을 받는 플랫 플레이트 슬래브 해석을 위한 수정된 등가골조모델)

  • Park Young Mi;Cho Kyung Hyun;Han Sang Whan;Lee Li Hyung
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.05a
    • /
    • pp.272-275
    • /
    • 2004
  • This study is to propose a modified equivalent frame method under lateral loading. ACI 318-02 allows the equivalent frame method to conduct slab analysis subjected to lateral loads. However, current method can not predict the behavior of the slabs particularly under lateral loading because the equivalent frame method in the ACI 318 has been developed against gravity loads. This study provides more precise model for the analysis of the flat plate slabs under lateral loading. The model reflect the force transfer mechanism of slabs, column and torsional member more accurately than the existing model. The accuracy of this model is verified by compared with finite element method analysis results.

  • PDF

A Comparison Study of Equivalent Strut Models for Seismic Performance Evaluation of Masonry-Infilled Frame (조적채움벽 골조의 내진성능평가를 위한 등가 스트럿 모델의 비교연구)

  • Yu, EunJong;Kim, MinJae;Jung, DaeGye
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.18 no.2
    • /
    • pp.79-87
    • /
    • 2014
  • Masonry-infilled walls have been used in reinforced concrete(RC) frame structures as interior and exterior partition walls. Since these walls are considered as nonstructural elements, they were only considered as additional mass. However, infill walls tend to interact with the structure's overall strength, rigidity, and energy dissipation. Infill walls have been analyzed by finite element method or transposed as equivalent strut model. The equivalent strut model is a typical method to evaluate masonry-infilled structure to avoid the burden of complex finite element model. This study compares different strut models to identify their properties and applicability with regard to the characteristics of the structure and various material models.

Pushover Analysis of an Unbraced 5-Story Steel Framed Structure for Arrangement of Semi-Rigid Connection (반강접 접합부 배치에 따른 비가새 5층 철골골조구조물의 비탄성 정적해석)

  • Kang, Suk-Bong;Kim, Sin-Ae
    • Journal of Korean Society of Steel Construction
    • /
    • v.22 no.4
    • /
    • pp.325-334
    • /
    • 2010
  • In this study, an unbraced five-story steel-framed structure was designed in accordance with KBC2005 to understand the features of structural behavior for the arrangement of semi-rigid connections. A pushover analysis of the structural models was performed, wherein all the connections were idealized as fully rigid and semi-rigid. Additionally, horizontal and vertical arrangements of the semi-rigid connection were adopted for the models. A fiber model was utilized for the moment-curvature relationship of the steel beam and the column, and a three-parameter power model was adopted for the moment-rotation angle of the semi-rigid connection. The top displacement, base-shear force, required ductility for the connection, sequence of the plastic hinge, and design factors such as the overstrength factor, ductility factor, and response modification coefficient were investigated using the pushover analysis of a 2D structure subjected to the equivalent static lateral force of KBC2005. The partial arrangement of the semi-rigid connection was found to have secured higher strength and lateral stiffness than that of the A-Semi frame, and greater ductility than the A-Rigid frame. The TSD connection was found suitable for use for economy and safety in the sample structure.