• Title/Summary/Keyword: 등가골조법

Search Result 11, Processing Time 0.023 seconds

Design of Flat Plate Systems Using the Modified Equivalent Frame Method (수정된 등가골조법을 이용한 플랫플레이트 시스템의 설계)

  • Park, Young-Mi;Oh, Seung-Yong;Han, Sang-Whan
    • Journal of the Korea Concrete Institute
    • /
    • v.20 no.1
    • /
    • pp.35-41
    • /
    • 2008
  • In general, flat plate systems have been used as a gravity load resisting system (GLRS) in building. Thus, this system should be constructed with lateral force resisting system (LFRS) such as shear walls and brace frames. GLRS should retain the ability to undergo the lateral drift associated with the LFRS without loss of gravity load carrying capacity. And flat plate system can be designed LFRS as ordinary moment frame with the special details. Thus, flat plate system designed as GLRS or LFRS should be considered internal forces (e.g., unbalanced moments) and lateral deformation generated in vicinity of slab joints render the system more susceptible to punching shear. ACI 318 (2005) allows the direct design method, equivalent frame method under gravity loads and allows the finite-element models, effective beam width models, and equivalent frame models under lateral loads. These analysis methods can produce widely different result, and each has advantage and disadvantages. Thus, it is sometimes difficult for a designer to select an appropriate analysis method and interpret the results for design purposes. This study is to help designer selecting analysis method for flat plate system and to verify practicality of the modified equivalent frame method under lateral loads. This study compared internal force and drift obtained from frame methods with those obtained from finite element method under gravity and lateral loads. For this purposes, 7 story building is considered. Also, the accuracy of these models is verified by comparing analysis results using frame methods with published experimental results of NRC slab.

Estimation of Interstory Drift for Moment Resisting Reinforced Concrete Frames Using Equivalent SDOF System (등가 1자유도계를 이용한 철근콘크리트 골조건물의 층간변위 응답 산정)

  • Kang, Ho-Geun;Jun, Dae-Han
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.8 no.5 s.39
    • /
    • pp.25-33
    • /
    • 2004
  • To evaluate the seismic capacity of a multistorey building structures in performance based seismic design, it is needed to convert MDOF model into equivalent SDOF model. This paper presents predictions for interstory drift of multistorey structures using method of converting a MDOF system into an equivalent SDOF model. The principal objective of this investigation is to evaluate appropriateness of converting method through performing nonlinear time history analysis of a multistory building structures and an equivalent SDOF model. Comparing the interstory drift of multistorey structures calculated by time history analysis and those evaluated by an equivalent SDOF model, the adequacy and the validity of converting method is verified. The conclusion of this study is following; A method of converting a MDOF system into an equivalent SDOF model through the nonlinear time history response analysis is valid. Inelastic first mode shapes are expected to be more accurate than elastic first mode shapes in obtaining interstory drift of multistorey structures from equivalent SDOF model.

Evaluation of Nonlinear Response for Moment Resisting Reinforced Concrete Frames Based on Equivalent SDOF System (등가 1 자유도계에 의한 철근콘크리트 모멘트 골조구조의 비선형 지진응답 평가법의 검토)

  • 송호산;전대한
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.7 no.1
    • /
    • pp.9-16
    • /
    • 2003
  • To evaluate the seismic performance of multistory building structures use an equivalent SDOF model to represent the resistance of the structure to deformation as it respond in its predominant mode. This paper presents a method of converting a MDOF system into an equivalent SDOF model. The principal objective of this investigation is to evaluate appropriateness of converting method through perform nonlinear time history analysis of a multistory building structures and an equivalent SDOF model. The hysteresis rules to be used an equivalent SDOF model is obtained from the pushover analysis. Comparing the peak inelastic response of a moment resisting reinforced concrete frames and an equivalent SDOF model, the adequacy and the validity of the converting method is verified. The conclusion of this study is following; A method of converting a MDOF system into an equivalent SDOF model through the nonlinear time history response analysis is valid. The representative lateral displacement of a moment resisting reinforced concrete frames is close to the height of the first modal participation vector \ulcorner$_1{\beta}$${_1{\mu}}=1$. It can be found that the hysteresis rule of an equivalent SDOF model have influence on the time history response. Therefore, it necessary for selecting hysteresis rules to consider hysteresis characteristics of a moment resisting reinforced concrete frames.

Lateral Stiffness of Steel Moment Frames Having Dogbone Seismic Connection (독본(dogbone) 내진접합부를 갖는 철골 모멘트골조의 횡강성 평가)

  • 이철호
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.15 no.4
    • /
    • pp.639-647
    • /
    • 2002
  • A simplified analytical procedure is presented to estimate the reduction of elastic lateral stiffness of steel moment frames arising from the radius-cut dogbone weakening. With the original radius-cut dogbone shape, it is almost impossible or too complicated to integrate analytically the mathematical expressions encountered when applying the conjugate beam method to compute the beam deflection component. In this study, the problem is circumvented by replacing the original radius-cut dogbone with an equivalent dogbone of constant width. The equivalence between the two is established by imposing an equal dogbone elongation criterion. This approach is justified by using a calibrated finite clement analysis. Then, the elastic lateral deflection components from the column, panel zone, and beam are derived for a typical beam-column subassembly. The derived results can be used to evaluate the reduction of the frame lateral stiffness. Case studies conducted within some practical ranges of frame configurations show that the reduction in frame lateral stiffness due to the presence of dogbone cut is on the order of 1 to 2 percent and is reasonably negligible in practical sense.

Modified Nonlinear Static Pushover Procedures of MDOF Bridgesfor Seismic Performance Evaluation (내진성능평가를 위한 다자유도 교량의 수정 비선형 등가정적해석법)

  • Cho, Chang-Geun;Kim, Young-Sang;Bae, Soo-Ho
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.10 no.4
    • /
    • pp.175-184
    • /
    • 2006
  • Two methods of the nonlinear static pushover analysis have been presented for the performance-based seismic design and evaluation of MDOF continuous bridges. Guidelines for buildings presented in FEMA-273 applying the Displacement Coefficient Method (DCM) and in ATC applying the Capacity Spectrum Method(CSM) have been modified for MDOF bridges. Two methods are compared with the time- history analysis. The lateral load distribution pattern for seismic loads has been examined in the static pushover analysis. The force-based fiber frame finite element has been implemented in the modeling of reinforced concrete piers.

A Study on the New Computational Methods for the Negative Moment at Column Support in PSC Flat Plate (PSC 연속 평판슬래브의 지점 부모멘트 산정법 연구)

  • 박선규;이범식;한만엽
    • Computational Structural Engineering
    • /
    • v.11 no.4
    • /
    • pp.177-186
    • /
    • 1998
  • PSC 연속 평판슬래브의 설계는 부정정 평판슬래브에 대한 정확한 해석의 어려움 등으로 등가보이론과 등가골조이론에 의한 근사식을 수정없이 사용하거나 컴퓨터를 이용한 해석에 의존하고 있으나 해석결과를 간단하게 정확히 평가할 수 있는 기법은 없는 실정이다. 또한 PSC 연속 평판슬래브의 부재력은 긴장재의 곡선형태에 따라 변하므로 실제 설계시 PS 긴장재의 정확한 곡선식을 찾는 것은 매우 중요하다. 본 연구에서는 비부착 PSC 연속 평판슬래브를 설계할 때 기둥과 기둥을 연결하는 PS 긴장재의 기하학적 곡선형태를 결정하는 방법과, PS 긴장력으로 인해 발생하는 평판슬래브의 기둥부 휨모멘트에 대하여 판이론을 기초로 간편하게 계산하는 방법을 제안하였다. 본 연구에서 제안된 이론으로 계산된 PSC 연속 평판슬래브에 대한 해석값과 유한요소 해석에 의한 지점 부모멘트를 비교 검토하여, 본 논문에서 제시한 기법의 타당성을 입증하였다. 따라서 본 연구는 설계자에게 컴퓨터의 해석결과를 간단하고 정확하게 검증할 수 있도록 하였다.

  • PDF

Current Control Device using TB-Equipped Circuit Equivalent Impedance Estimation and RF Relay (회로 등가임피던스 추정 및 RF 릴레이 장착한 TB를 이용한 방식전류제어장치)

  • Lee, Dong-Jun;Park, Seong-Mi;Park, Sung-Jun
    • Proceedings of the KIPE Conference
    • /
    • 2019.07a
    • /
    • pp.358-359
    • /
    • 2019
  • 철교나 석유비축기지 탱크저판 및 각종 매설관로 등 대부분 철 성분 골조는 시간이 경과하면 주변의 환경에 따라 부식이 급격히 일어난다. 이러한 철강재가 부식되는 철강재가 시설물의 주요 구성물이 되고 있는 시설물의 수명을 크게 단축시키는 주요원인이 되고 있다. 이에 대한 대비책으로 방청도료나 코팅을 이용하는 방법과 달리, 전기적으로 전위차를 같게 하여 부식을 방지하는 전기방식법을 적용함에 있어 방식전류가 불균일한 경우 양극 소모가 불균일함에 따라 교체시기 문제를 극복하기 위해 회로 등가 임피던스 추정 및 RF 릴레이 장착한 TB를 이용한 방식전류제어장치를 개발하였다.

  • PDF

Capacity Spectrum Method Based on Inelastic Displacement Ratio (비탄성변위비를 이용한 능력 스펙트럼법)

  • Han, Sang-Whan;Bae, Mun-Su
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.12 no.2
    • /
    • pp.69-80
    • /
    • 2008
  • In this study, improved capacity spectrum method (CSM) is proposed. The method can account for higher mode contribution to the seismic response of MDOF systems. The CSM has been conveniently used for determining maximum roof displacement using both demand spectrum and capacity curve of equivalent SDOF system. Unlike the conventional CSM, the maximum roof displacement is determined without iteration using inelastic displacement ratio and R factor calculated from demand spectrum and capacity curve. Three moment resisting steel frames of 3-, 9- and 20-stories are considered to test the accuracy of the proposed method. Nonlinear response history analysis (NL-RHA) for three frames is also conducted, which is considered as an exact solution. SAC LA 10/50 and 2/50 sets of ground motions are used. Moreover, this study estimates maximum story drift ratios (IDR) using ATC-40 CSM and N2-method and compared with those from the proposed method and NL-RHA. It shows that the proposed CSM estimates the maximum IDR accurately better than the previous methods.

A Study on Forced Vibration Tests on a Structure with Stud Type of Vibration Control Damper (스터드형 진동제어 강재댐퍼가 장착된 3층 강구조 골조의 강제진동실험에 관한 연구)

  • Lee, Seung-Jae
    • Journal of Korean Association for Spatial Structures
    • /
    • v.6 no.2 s.20
    • /
    • pp.115-121
    • /
    • 2006
  • In recent years vibration control damper made of low yield point steel is expected to play an important role in controlling structural vibration induced earthquake and wind. But their dynamic characteristics and energy dissipation effects on the whole structure model are not clarified. In this paper, firstly, we presents the results of cyclic tests on low yield steel dampers. Secondly, forced vibration tests on existence three stories steel structure model with low yield point steel dampers are presented. Lastly, it is estimated energy amount which is dissipated through the hysteresis dampers by using two types of analytical models, hysteresis model and equivalent linear model.

  • PDF

Effective Beam Width for Flat-Plate Systems Having Edge Beams under Lateral Loads (수평하중을 받는 테두리보가 있는 플랫플레이트 시스템의 유효보폭계수)

  • Han, Sang-Whan;Cho, Ja-Ock;Park, Young-Mi
    • Journal of the Korea Concrete Institute
    • /
    • v.20 no.2
    • /
    • pp.213-219
    • /
    • 2008
  • The purpose of this study is to propose frame analysis method for flat plate slabs having edge beam under lateral loads. Flat plate system is defined as the system only with slab of uniform thickness and column. However, the slab system generally incorporate edge beams at exterior connection in actual design. ACI 318 (2005) allows three methods for conducting flat plate system analysis subjected to lateral loads. There are the finite element method (FEM), the equivalent frame method (EFM), and the effective beam width method (EBWM). Among methods, the EBWM enables us to analyze practically by substituting the actual slab to beam element. In this model, the beam element has a thickness equal to that of the slab, and effective beam width equal to some fraction of the slab transverse width. However, the established EBWM was generally proposed for variables of geometry or stiffness reduction factor and seldom proposed for the effect of edge beams. This study verifies that, in the case of flat plate system having edge beams at exterior connections, the lateral stiffness is considerably larger than without edge beams. Therefore it need to analysis method for considered the effect of edge beams. In this study, an analysis model is proposed for the flat plate system having edge beams under lateral loads by considering the effect of edge beams. To verify the accuracy of proposed model, this study compared results of the proposed EBWM with results of FEM of flat plate systems having edge beams under lateral loads. Also, the proposed approach is compared with experimental results of former research.