• Title/Summary/Keyword: 두부규격방사선촬영

Search Result 45, Processing Time 0.031 seconds

A comparative study of guiding methods for natural head posture in cephalometrics (두부방사선규격사진 촬영 시 유도방법에 따른 자연두부자세의 차이 및 재현성에 관한 연구)

  • Song, Jin-Myoung;Lee, Ki-Heon;Hwang, Hyeon-Shik
    • The korean journal of orthodontics
    • /
    • v.35 no.5 s.112
    • /
    • pp.341-350
    • /
    • 2005
  • The Purpose of this study was to compare the degree of vortical head rotation and to evaluate the reproducibility of natural Head posture (NHP) according to two guiding methods, the head posture aligner (HPA) method and the solf balance posture (SBP) method. The subjects consisted of 30 adults. On the first day. lateral and frontal cephalometric radiographs were obtained through the two guiding methods. One mouth later. lateral and frontal cephalometric radiographs were obtained again through both guiding methods. The degrees of vertical head rotation of both guiding methods were compared and the reproducibility was evaluated for each guiding method. A comparison of the degrees of vortical head rotation for the two methods revealed that the vertical head posture was lower in the SBP method than in the HPA method by an average of $2.79^{\circ}$. All measurements obtained using the HPA and SBP methods with a time interval of one north did not show any significant difierence in lateral and frortal cephalometric radiographs. The results of the present study suggest that the SBP method may be used as an alternative to the HPA method in case the HPA method can not be applied.

Study on Research for Reducing Radiation Dose of Head and Neck for Cephalometric Radiography System (두부규격방사선촬영장치의 두경부 피폭 저감에 대한 연구)

  • OH, Yoonjin;Shin, Jae-won;Lee, Samyol
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.5
    • /
    • pp.291-298
    • /
    • 2016
  • Recently, the interest in the orthodontic treatment for children is increased by a rise in national income level. The number of cephalometric radiography that could diagnose a malocclusion and malposition between teeth and jawbone increased. It required attention to radiation exposure, because the subject of dental examination is children which are more sensitive to radiation and the head and neck, the object of that include radiation sensitive organ such as the thyroid, bone marrow, eyes, salivary gland, and so on. In this study, we measured two-dimensional dose distribution in cephalometric radiography system (VATEC Pax-400C) using Agfa CP-G Plus film and MagicMax Dosimeter, and calculated radiation organ dose of head and neck through MCNPX simulation. And then we designed a radiation protective device to decrease radiation dose. The dose distribution of the cephalometric radiography system irradiated the head and neck overall as well as the oral and maxillofacial parts. The radiation organ dose calculated that thyroid, oesophagus and eyes are irradiated high, and the radiation organ dose decreased about 70 ~ 80% by the application of the radiation protective device. The results of this study will be used construction of database for dental radiation exposure and research of reducing radiation dose.

Comparison of midsagittal reference plane in PA cephalogram and 3D CT (3차원 전산화 단층촬영의 Nasion, Sella, Basion으로 구성된 정중 시상 평면과 정면 두부방사선 규격사진의 정중 시상 평면 비교)

  • Cho, Jin-Hyoung;Moon, Ji-Yeon
    • The korean journal of orthodontics
    • /
    • v.40 no.1
    • /
    • pp.6-15
    • /
    • 2010
  • Objective: The aim of this study is to find the most helpful midsagittal reference plane for diagnosis in PA cephalometry compared with 3D CT. Methods: The subjects consisted of 25 adults who showed no facial asymmetry by gross inspection. 3D CT and posteroanterior cephalogram of the subjects were taken. To find the most helpful midsagittal reference plane in PA cephalometry, we considered five kinds of midsagittal planes from which the distances to five landmarks were measured and compared the result with that of 3D CT. The midsagittal plane for 3D CT was determined by the landmarks Nasion, Sella and Basion. Results: PA measurements using the midsagittal reference plane on a perpendicular plane lying through the midpoint of the right and left latero-orbitales was closest to those of 3D CT. Conclusions: It was considered that latero-orbitale perpendicular could be used as the helpful midsagittal reference plane to assess facial asymmetry in PA cephalometry.

The Validity of Head Posture Aligner in Posteroanterior Cephalometry (정모 두부 방사선 사진 촬영시 Head Posture Aligner의 유용성에 관한 연구)

  • Kim, Eun-Hee;Hwang, Hyeon-Shik
    • The korean journal of orthodontics
    • /
    • v.30 no.5 s.82
    • /
    • pp.543-552
    • /
    • 2000
  • The purposes of this study were to evaluate the reproducibility of posteroanterior(PA) cephalograms obtained by two methods, the Head Posture Aligner(HPA) method in natural head posture and the conventional method(operator-guided method), and to compare the vertical rotational differences of the head Posture between lateral and PA cephalograms according to the method. The sample was consisted of 30 adults. At first day, a PA cephalogram and a lateral cephalogram were obtained from each subject by two methods to investigate the difference of vertical rotational posture between lateral and PA cephalograms. Two weeks later, another PA cephalogram was obtained using each method to evaluate the reproducibility of head posture. Five height measurements and nine width measurements were used in the paired t-test to compare the reproducibility of the PA cephalometric measurements between two methods. The differences of vertical rotational posture between lateral and PA cephalograms were calculated from a computer program and compared according to the method used, and following results were obtained. 1. Height measurements obtained by operator-guided method showed significant differences according to the time interval and revealed low reproducibility. 2. Height measurements obtained by HPA method did not show significant differences according to the time interval and presented high reproducibility. 3. In the comparison of width measurement, two methods did not show distinct differences in reproducibility. 4. The difference of vertical rotational posture between lateral and PA cephalograms showed $0.8^{\circ}$ in the HPA method, more less than $2.5^{\circ}$ in the operator-guided method. The results of the present study suggest that the HPA may be helpful in the PA cephalometric radiography in terms of reproducibility.

  • PDF

The comparative study of three-dimensional cephalograms to actual models and conventional lateral cephalograms in linear and angular measurements (3차원 두부방사선규격사진의 정확성에 관한 연구 -실제 계측 및 측모 두부방사선 규격사진 계측과의 비교-)

  • BAE, Gi-Sun;Park, Soo-Byung;Son, Woo-Sung
    • The korean journal of orthodontics
    • /
    • v.27 no.1
    • /
    • pp.129-140
    • /
    • 1997
  • Conventional cephalometrics have inherent errors because their evaluation is performed in two-dimension for threedimensional object. To compensate these errors, three-dimensional cephalograms - derivation of three-dimensional data from conventional lateral and postero-anterior cephalograms - were developed. In this study, the accuracy and precision of three dimensional cephalograms were determined by means of 10 linear and 12 angular measurements on 36 acrylic skull models and by the comparison of conventional lateral cephalograms. The results were as follows 1. Mean difference between three-dimensional cephalograms and actual models in linear measurements was $0.94{\pm}0.62mm$ and mean rate of magnification of three-dimensional cephalograms was $100.31{\pm}0.91%$. There were no statistically significant differences between three-dimensional cephalograms and actual models in linear measurements(${\alpha}=0.1$). 2. Mean difference between conventional lateral cephalograms and actual models in linear measurements was $6.44{\pm}1.48mm$ and mean rate of magnification of lateral cephalograms was $106.99{\pm}1.45%$. There were statistically significant differences between lateral cephalograms and actual models in linear measurements(P<0.005). 3. Mean difference between three-dimensional cephalograms and actual models in angular measurements was $1.22{\pm}0.82^{\circ}$ and mean rate of magnification of three-dimensional cephalograms was $105.71{\pm}12.07%$. There were no statistically significant differences between three-dimensional cephalograms and actual models in angular measurements(${\alpha}=0.1$). 4. Mean difference between conventional lateral cephalograms and actual models in angular measurements was $1.70{\pm}0.94^{\circ}$ and mean rate of magnification of lateral cephalograms was $106.35{\pm}15.70%$. There were no statistically significant differences between lateral cephalograms and actual models in angular measurements(${\alpha}=0.1$). There were similarity between three-dimensional and lateral cephalograms in angular measurements.

  • PDF

EFFECTS ON THE ENLARGEMENT RATIOS DUE TO CHANGES OF HEAD POSTURE ON LATERAL HEADFILMS (측두 규격방사선사진 촬영시 두부의 위치변화가 확대율에 미치는 영향)

  • Seo, Young-Hun;Choi, Yeong-Chul
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.28 no.1
    • /
    • pp.185-194
    • /
    • 2001
  • This study was designed to evaluate the effects of angulation changes of head posture on the enlargement ratios of a lateral headfilm depending on the vortical or horizontal rotation of the objects. A device was constructed to measure regional changes of enlargement ratios. The device was held within the cephalostat and cephalograms recorded at each measured degrees of the device tilting, vertically and horizontally. The enlargement ratios of the horizontal, vertical, and angular measurements on the films taken at each tilted angulations were obtained and compared with those on the films taken without rotation. In summary, the enlargement ratios of the horizontal linear measurements were decreased during horizontal rotations. The enlargement ratios of vortical measurements of the right side on the film were increased and those of the left side were decreased by the horizontal rotations. Enlargement ratios of horizontal measurements were affected further than those of vertical measurements by the same angular changes of the horizontal rotations. Therefore, a disruption of parallelism between the object's midsagittal plane and the film could result in distortion of the image while vertical rotation around the object's porionic axis would not significantly affect the enlargement ratios on the headfilm.

  • PDF

DEVELOPMENT OF THREE DIMENSIONAL MEASURING PROGRAM WITH FRONTAL AND LATERAL CEPHALOMETRIC RADIOGRAPHS -PART 1. COMPUTATION OF THE THREE-DIMENSIONAL COORDINATES BY COMPENSATION OF THE ERROR OF THE HEAD POSITION IN ORDINARY NON-BIPLANAR CEPHALOSTAT- (정모 및 측모 두부 방사선 규격사진을 이용한 3차원 계측 프로그램의 개발 -1. 단일 방사선원으로 촬영된 두부 방사선사진의 두부 위치 보정을 이용한 3차원 좌표의 산출-)

  • Lee, Geun-Ho;Lee, Sang-Han;Jang, Hyon-Joong;Kwon, Tae-Geon
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.27 no.3
    • /
    • pp.214-220
    • /
    • 2001
  • The clinical application of the three-dimensional radiographic technique had been limited to standard Broadbent-Bolton cephalometer with biplanar stereoradiography. We developed a new method for compensating the error of head position in ordinary non-biplanar cephalostat. It became to possible to use the three dimensional cephalogram commonly in clinical bases. 1. The method of methemetical compensation of head positioning error in non-biplanar condition was evaluated with dry skull. The error of the method of first and the second trial was $0.46{\pm}1.21$, $0.33{\pm}0.90mm$, which means the error of the head positioning correction in conventional cephalogram was within clinical acceptance. 2. The reproducibility of this system for clinical application was 0.54 mm ($-2.99{\sim}2.26mm$) which defines the absolute mean difference of the first and second trial. Compare to the The landmark identification error $1.2{\pm}1.6mm$, the error of the measurement was within the range of landmark identification error. The result indicates the adequate clinical accuracy of the computation of three-dimensional coordinates by compensation of the error of the head position in ordinary non-biplanar cephalostat.

  • PDF

THREE DIMENSIONAL ANALYSIS OF MAXILLOFACIAL STRUCTURE BY FRONTAL AND LATERAL CEPHALOGRAM (두부 방사선 규격사진을 이용한 악안면 구조의 3차원적 분석법)

  • Kwon, Kui-Young;Lee, Sang-Han;Kwon, Tae-Geon
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.21 no.2
    • /
    • pp.174-188
    • /
    • 1999
  • The purpose of this study is to evaluate the precision and accuracy of a three dimensional cephalogram constructed by using the frontal and lateral cephalogram of twelve human dry skulls. After achieving the three dimensional image reconstruction program, we tried to apply this program to two dentofacial deformity patients. 1. Conventional nasion relator in cephalostat was used to reproduce the same head position for the same dry skull. The mean difference of the three dimensional cephalogram for the same dry skull was $0.34{\pm}0.33mm$. Closeness of repeated measures to each skull reveals the precision of this method for the three dimensional cephalogram. 2. Concerning the accuracy, the mean difference between the three dimensional reconstruction data and actual lineal measurements was $1.47{\pm}1.45mm$ and the mean magnification ratio was $100.24{\pm}4.68%$. This Diffrerence is attributed mainly to the ill defined cephalometric landmarks, not to the positional change of the dry skull. 3. Cephalometric measurement of lateral and frontal radiographs had no consecutive magnification ratio because of the different focus-object distance. The mean difference between the frontal and lateral cephalogram to the actual lineal measurements was $4.72{\pm}2.01mm$ and $-5.22{\pm}3.36mm$. Vertical measurements were slightly more accurate than horizontal measurements. 4. Applying to the actual patient analysis, it is recommendable to use this program for analyzing the asymmetry or spatial change after operation. The orthodontic bracket would be a favorable cephalometric landmark for constructing the three dimensional images.

  • PDF

Three-dimensional CT image study on the correction of gonial angle width enlarged on frontal cephalogram (정모두부방사선사진에서 하악골 우각부 영상확대 및 이의 보정에 관한 3차원 CT영상 연구)

  • Hwang, Hyeon-Shik;Eun, Chun-Sun;Hwang, Chung Hyon;Lim, Hoi-Jeong
    • The korean journal of orthodontics
    • /
    • v.35 no.4 s.111
    • /
    • pp.251-261
    • /
    • 2005
  • Enlargement is an inherent property of X-rays which occurs when straight hues diverse from small a focal spot. The purpose of the present study was to evaluate the validity of the correction of gonial angle width enlarged on frontal cephalogram, using frontal and lateral cephalograms taken orthogonally from each other. In 40 adult individuals, frontal and lateral cephalograms were taken at a $90^{\circ}$ angle using the Head Posture Aligner. The angle width was measured on the frontal cephalogram and subsequently. the corrected angle width was calculated using the magnification rate of two cephalograms. Measured and corrected angle widths were compared with the measurement from the 3D CT image. The measurement or the frontal cephalogram showed a 9.10mm of enlargement on average ranging from 7.92 to 11.31mm. Corrected angle width measurement showed a 0.14mm difference with the 3D CT image measurement, which was not statistically significant. The results of the study indicate that actual au91e width can be approached through calculation using frontal and lateral cephalograms taken orthogonally with the help of the Head Posture Aligner The study also showed that the magnitude of correction error did not show a significant correlation with the amount of menton deviation, and it suggests that the present correction method is valid even in individuals with severe facial asymmetry.

Treatment Outcome of Mandibular Advancement Device in Obstructive Sleep Apnea Patients- Polysomnographic and Cephalometric analyses (수면무호흡증 환자에서 수면다원검사와 두부규격방사선사진을 이용한 하악전방이동장치의 치료효과에 관한 연구)

  • Chung, Jin-Woo;Kim, Ebee;Kim, Sung-Hun
    • Journal of Oral Medicine and Pain
    • /
    • v.38 no.2
    • /
    • pp.203-213
    • /
    • 2013
  • Objecives : The purpose of the study was to evaluate treatment outcome of mandibular advancement device(MAD) in obstructive sleep apnea (OSA) patients using full night polysomnography and cephalometry. Methods : Twenty-seven OSA patients were confirmed by full night, lab-attended polysomnography. Cephalometric examinations were conducted to obtain SNA, ANB, $AH{\bot}MP$, AH-C3, SPT, PNS-U, NAS, SOAS, MOAS, and HAS. Mandibular advancement devices (MADs) were fabricated and delivered for all subjects. After acclimation period of MAD, the second polysomnographic examinations were conducted in the same manner. Polysomnographic variables were compared between before and after MAD placement. Also, correlation coefficients were calculated between apnea-hypopnea index (AHI) and each item of cephalometric parameters. Results : There were significant improvements in total AHI, lowest $SpO_2$, and total arousal index after MAD therapy. Also, there were significant improvements in NREM $SpO_2$ and NREM AHI, but not in REM $SpO_2$ and REM AHI with MAD. Stratifying the sleep stage, there were significant decrease in stage I and significant increases in stage II and REM, but change in stage III was not significant. SNA and SOAS were significantly correlated with total AHI and NAS was significantly correlated with supine AHI. ANB was significantly associate with the effect of MAD. Conclusions : MAD is an effective treatment in OSA patients comparing polysomnographic variables before and after treatment. Cephalometric examination can be useful to evaluate OSA patients and predict treatment outcome of MAD.