• Title/Summary/Keyword: 동전기-펜턴 공정

Search Result 7, Processing Time 0.021 seconds

Electrokinetic-Fenton Process for Removal of Phenanthrene (동전기-펜턴 공정을 이용한 phenanthrene 오염토양의 정화)

  • 양지원;박지연;김상준;이유진;기대정
    • Journal of Soil and Groundwater Environment
    • /
    • v.9 no.1
    • /
    • pp.47-53
    • /
    • 2004
  • Feasibility of electrokinetic process combined with Fenton-like reaction was investigated for the removal of phenanthrene from contaminated soil. Transport of hydrogen peroxide by electroosmosis and decomposition of phenanthrene by Fenton-like reaction were observed in a model system. Electrical potential gradient and electroosmotic flow (EOF) at 10 mA were higher than those at 5 mA. High accumulated EOF resulted in high removal efficiency of phenanthrene because the large amount of hydrogen peroxide was transfered through the soil. Removal efficiency of phenanthrene by water washing was 8.5% for 7 days. The highest removal efficiency including phenanthrene decomposition was 95.6% for 14 days. After the operation, soil samples with removal efficiency of 95.6% showed low concentrations of phenanthrene and its intermediates. From this result, it was presumed that phenanthrene was decomposed to small molecules or mineralized to water and carbon dioxide due to continuous supply of hydrogen peroxide by electroosmotic flow.

Role of Electrode Reaction of Electrolyte in Electrokinetic-Fenton Process for Phenanthrene Removal (동전기-펜턴 공정에서 전해질의 전극반응이 처리효율에 미치는 영향)

  • Park Ji-Yeon;Kim Sang-Joon;Lee You-Jin;Yang Ji-Won
    • Journal of Soil and Groundwater Environment
    • /
    • v.11 no.1
    • /
    • pp.7-13
    • /
    • 2006
  • The effects of electrolytes were investigated on the removal efficiency when several different electrolytes were used to change the electrode reaction in an electrokinetic (EK)-Fenton process to remediate phenanthrene-contaminated soil. Electrical potential gradient decreased initially due to the ion entrance into soil and then increased due to the ion extraction from soil under the electric field. Accumulated electroosmotic flow was $NaCl>KH_2PO_4>MgSO_4$ at the same concentration because the ionic strength of $MgSO_4$ was the highest and $Mg(OH)_2$ formed near the cathode reservoir plugged up soil pore to inhibit water flow. When hydrogen peroxide was contained in electrolyte solution, removal efficiency increased by Fenton reaction. When NaCl was used as an electrolyte compound, chlorine ($Cl_2$) was generated at the anode and dissolved to form hypochlorous acid (HClO), which increased phenanthrene removal. Therefore, the electrode reaction of electrolyte in the anode reservoir as well as its transport into soil should be considered to improve removal efficiency of EK-Fenton process.

Removal of Phenanthrene by Electrokinetic-Fenton Process in a 2-dimensional Soil System (동전기-펜턴 공정을 이용한 2차원 토양 정화장치에서의 phenanthrene 제거)

  • Park Ji-Yeon;Kim Sang-Joon;Lee You-Jin;Yang Ji-Won
    • Journal of Soil and Groundwater Environment
    • /
    • v.10 no.5
    • /
    • pp.11-17
    • /
    • 2005
  • Characteristics of phenanthrene removal in the Electrokinetic (EK)-Fenton process were investigated in a 2-dimensional test cell in a viewpoint of the effect of gravity and electrosmotic flow (EOF). When the constant voltage of 100 V was applied to this system, the current decreased from 1,000 to 290 mA after 28 days, because soil resistance increased due to the exhaustion of ions in soil by electroosmosis and electromigration. Accumulated EOF in two cathode reservoirs was 10.3 L and the EOF rate was kept constant for 28 days. At the end of operation, the concentration of phenanthrene was observed to be very low near the anode and increased in the cathode region because hydrogen peroxide was supplied from anode to cathode region following the direction of EOP. Additionally, the concentration of phenanthrene decreased at the bottom of the test cell because the electrolyte solution containing hydrogen peroxide was largely transported toward the bottom due to a low capillary action in the soil with high porosity. Average removal efficiency of phenanthrene by EK-Fenton process was 81.4% for 28 days. In-situ EK-Fenton process would overcome the limitations of conventional remediation technologies and effectively remediate the contaminated sites.

Effect of ionic Strength of Electrolyte on Phenanthrene Removal in Electrokinetic-Fenton Process (동전기-펜턴 공정에서 phenanthrene 제거에 대한 전해질 이온세기의 영향)

  • Park Ji-Yeon;Kim Sang-Joon;Lee You-Jin;Yang Ji-Won
    • Journal of Soil and Groundwater Environment
    • /
    • v.10 no.4
    • /
    • pp.18-25
    • /
    • 2005
  • Characteristics of phenanthrene removal in an electrokinetic (EK)-Fenton process were investigated in a viewpoint of concentration and ionic strength of electrolytes. When three kinds of electrolytes (NaCl, $KH_2PO_4,\;and\;MgSO_4$) were used, the increase in electrolyte concentration caused the decrease of electrical potential gradient. The increase of electrical conductivity was due to the increase of ionic concentration in soil. The decrease of accumulated electroosmotic flow (EOF) with increase in electrolyte concentration was due to the decrease of zeta potential. The removal efficiency was in proportion to accumulated EOF which depended on ionic strength. Total energy expenditure without electrolyte was 10-30 times higher than its with 0.5 M electrolyte. The lower removal efficiency was caused by the lower energy expenditure with 0.5 M one. An effective EK-Fenton process was determined from considering the removal efficiency and the energy expenditure, simultaneously.

동전기-펜턴 토양정화공정에서 공정변수에 따른 분해성능 비교

  • 양지원;박지연;김상준;이유진
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2002.09a
    • /
    • pp.239-242
    • /
    • 2002
  • Removal of phenanthrene by electrokinetic (EK) method combined with Fenton-like process was studied in a model system. Sand and phenanthrene were selected as a model soil and a representative PAH. Sand was contaminated at the concentration of 500 mg phenanthrene/kg dry sand. Bentonite and kaolinite were inserted into the space between reservoir and contaminated soil. When hydrogen peroxide supplied to a soil system from the anode reservoir was transported through the soil by EK process, the Fenton-like reaction was occurred by naturally existing iron minerals in soil. When hydrogen peroxide was supplied into the system, it showed higher removal efficiency than when just water was used. Maximum removal efficiency of phenanthrene was 81.2 % for 7 days.

  • PDF

3차원 토양 실험장치에서 동전기-펜턴 공정의 전기삼투흐름 모사

  • 박지연;김상준;이유진;기대정;양지원
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2003.09a
    • /
    • pp.158-161
    • /
    • 2003
  • Removal of phenanthrene by electrokinetic method combined with Fenton-like process was studied in a model system. The scale of reactor was 100cm in length, 100cm in width, and 70cm in height. The distance between electrodes was 70cm. Indonesia kaoline was selected as a model soil. When constant voltage of 100 V was applied to this system, current decreased from 200 mA to 100 mA for 14 days. Total accumulated EOF was about 55,000 mL. The concentration of phenanthrene near anode was very low because direction of electroosmosis was from anode to cathode and hydrogen peroxide was supplied to anode reservoir. Phenanthrene concentration was increased as the location was far from anode because hydrogen peroxide was gradually decomposed and then the rate of hydroxyl radical production was decreased.

  • PDF

2차원 토양 실험장치에서 동전기-펜턴 공정의 이해

  • 양지원;박지연;김상준;이유진;기대정
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2003.04a
    • /
    • pp.310-313
    • /
    • 2003
  • Removal of phenanthrene by electrokinetic method combined with Fenton-like process was studied in a model system. The scale of reactor was 120 cm in length, 10 cm in width, and 50 cm in height. Sand was selected as a model soil. Bentonite was filled in the space between reservoir and contaminated soil to control the flow rate of water. When constant voltage of 100 V was applied to this system, current varied from 1000 mA to 290 mA for 28 days. pH of anode and cathode reservoirs became to 2 and 13, respectively. Removal efficiency of phenanthrene was more than 60 %.

  • PDF