• Title/Summary/Keyword: 동적 용량

Search Result 287, Processing Time 0.021 seconds

Time Series Patterns and Clustering of Rotifer Community in Relation with Topographical Characteristics in Lentic Ecosystems (정수생태계의 지형적인 요인 변화와 윤충류 출현 종 수 및 개체군 밀도 변동에 대한 연구)

  • Oh, Hye-Ji;Heo, Yu-Ji;Chang, Kwang-Hyeon;Kim, Hyun-Woo
    • Korean Journal of Ecology and Environment
    • /
    • v.54 no.4
    • /
    • pp.390-397
    • /
    • 2021
  • The time series data of rotifer community focusing on the species number and total density were collected from 29 reservoirs located at Jeonnam Province from 2008 to 2016 quarterly. The reservoirs had similar weather condition during the study period, but their sizes and water qualities were different. To analyze the temporal dynamics of rotifer community, the medians, ranges, outliers and coefficient of variation (CV) value of rotifer species number and abundance were compared. For the temporal trend analysis, time series of each reservoir data were compared and clustered using the dynamic time warping function of the R package "dtwclust". Small-sized reservoirs showed higher variability in rotifer abundance with more frequent outliers than large-sized reservoirs. On the other hand, apparent pattern was not observed for the rotifer species number. For the temporal pattern of rotifer density, COD, phytoplankton abundance fluctuation, and cladoceran abundance fluctuation have been suggested as potential factor affecting the rotifer abundance dynamics.

Analysis Program for Offshore Wind Energy Substructures Embedded in AutoCAD (오토캐드 환경에서 구현한 해상풍력 지지구조 해석 프로그램)

  • James Ban;Chuan Ma;Sorrasak Vachirapanyakun;Pasin Plodpradit;Goangseup Zi
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.27 no.4
    • /
    • pp.33-44
    • /
    • 2023
  • Wind power is one of the most efficient and reliable energy sources in the transition to a low-carbon society. In particular, offshore wind power provides a high-quality and stable wind resource compared to onshore wind power while both present a higher installed capacity than other renewables. In this paper, we present our new program, the X-WIND program well suitable for the assessment of the substructure of offshore wind turbines. We have developed this program to increase the usability of analysis programs for offshore wind energy substructures by addressing the shortcomings of existing programs. Unlike the existing programs which cannot solely perform the substructure analyses or lack pre-post processors, our X-WIND program can complete the assessment analysis for the offshore wind turbines alone. The X-WIND program is embedded in AutoCAD so that both design and analysis are performed on a single platform. This also performs static and dynamic analysis for wind, wave, and current loads, essential for offshore wind power structures, and includes pre/post processors for designs, mesh developments, graph plotting, and code checking. With this expertise, our program enhances the usability of analysis programs for offshore wind energy substructures, promoting convenience and efficiency.

Generation of calibration standard gases using capillary gas divider: uncertainty measurement and method validation (다중 모세관을 이용한 교정용 표준가스의 제조: 불확도와 유효성 평가)

  • Lee, Sangyun;Hwang, Eun-Jin;Jung, Hye-Ja;Lee, Kwang-Woo;Chun, Ki-Joon
    • Analytical Science and Technology
    • /
    • v.19 no.5
    • /
    • pp.369-375
    • /
    • 2006
  • Calibration gas mixtures were prepared using dynamic volumetric method according to ISO 6145-5 and the uncertainty was evaluated. Ten identical capillaries with 0.25 mm in inner diameter and 50 cm in length were applied in this system. Dilution ratio of parent gas was determined by the number of capillaries that passes parent gas and that passes balance gas through. Capillaries were made of Teflon which had good chemical stability against adsorption of gaseous substances. Mechanical valves were introduced in this system in order to minimize the thermal effect of solenoid valves. Concentration of prepared gases were compared with master grade standard gases in cylinders made by RiGAS Co. and calibration of the instrument were completed using comparison method according to ISO 6143. Experimental results showed that the coefficient of variance of diluted oxygen standard gases showed less then 0.2% in most dilution range, that of diluted hydrogen sulfide standard gases showed less then 1.0%. Therefore, it is proven that the standard gases prepared by this system are appropriate to be used as a calibration standards in ambient monitoring, etc.

Stand-alone Real-time Healthcare Monitoring Driven by Integration of Both Triboelectric and Electro-magnetic Effects (실시간 헬스케어 모니터링의 독립 구동을 위한 접촉대전 발전과 전자기 발전 원리의 융합)

  • Cho, Sumin;Joung, Yoonsu;Kim, Hyeonsu;Park, Minseok;Lee, Donghan;Kam, Dongik;Jang, Sunmin;Ra, Yoonsang;Cha, Kyoung Je;Kim, Hyung Woo;Seo, Kyoung Duck;Choi, Dongwhi
    • Korean Chemical Engineering Research
    • /
    • v.60 no.1
    • /
    • pp.86-92
    • /
    • 2022
  • Recently, the bio-healthcare market is enlarging worldwide due to various reasons such as the COVID-19 pandemic. Among them, biometric measurement and analysis technology are expected to bring about future technological innovation and socio-economic ripple effect. Existing systems require a large-capacity battery to drive signal processing, wireless transmission part, and an operating system in the process. However, due to the limitation of the battery capacity, it causes a spatio-temporal limitation on the use of the device. This limitation can act as a cause for the disconnection of data required for the user's health care monitoring, so it is one of the major obstacles of the health care device. In this study, we report the concept of a standalone healthcare monitoring module, which is based on both triboelectric effects and electromagnetic effects, by converting biomechanical energy into suitable electric energy. The proposed system can be operated independently without an external power source. In particular, the wireless foot pressure measurement monitoring system, which is rationally designed triboelectric sensor (TES), can recognize the user's walking habits through foot pressure measurement. By applying the triboelectric effects to the contact-separation behavior that occurs during walking, an effective foot pressure sensor was made, the performance of the sensor was verified through an electrical output signal according to the pressure, and its dynamic behavior is measured through a signal processing circuit using a capacitor. In addition, the biomechanical energy dissipated during walking is harvested as electrical energy by using the electromagnetic induction effect to be used as a power source for wireless transmission and signal processing. Therefore, the proposed system has a great potential to reduce the inconvenience of charging caused by limited battery capacity and to overcome the problem of data disconnection.

Use of Mammary Lymphoscintigraphy and Intraoperative Radioguided Gamma Probe in Sentinel Lymph Node Biopsy of Breast Cancer (유방암 환자의 전초림프절 생검에서 유방림프신티그라피와 수술 중 감마프로우브의 유용성)

  • Kim, Soon;Zeon, Seok-Kil;Kim, Yu-Sa
    • The Korean Journal of Nuclear Medicine
    • /
    • v.34 no.6
    • /
    • pp.478-486
    • /
    • 2000
  • Purpose: The sentinel lymph node is defined as the first draining node from a primary tumor and reflects the histologic feature of the remainder of the lymphatic basin status. The aim of this study was to evaluate the usefulness of lymphoscintigraphy and intraoperative radioguided gamma probe for identification and removal of sentinel lymph node in breast cancer. Materials and Methods: Lymphoscintigraphy was performed preoperatively in 15 patients with biopsy proven primary breast cancer. Tc-99m antimony sulfide colloid was injected intradermally at four points around the tumor. Imaging acquisition included dynamic imaging, followed by early and late static images at 2 hours. The sentinel lymph node criteria on lymphoscintigraphy is the first node of the highest uptake in early and late static images. We tagged the node emitting the highest activity both in vivo and ex vivo. Histologic study for sentinel and axillary lymph node investigation was done by Hematoxylin-Eosin staining. Results: On lymphoscintigraphy, three of 15 patients had clear lymphatic vessels in dynamic images, and 11 of 15 patients showed sentinel lymph node in early static image and three in late static 2 hours image. Mean detection time of sentinel lymph node on lymphoscintigraphy was $33.5{\pm}48.4$ minutes. The sentinel lymph node localization and removal by lymphoscintigraphy and intraoperative gamma probe were successful in 14 of 15 patients (detection rate: 93.3%). On lymphoscintigraphy, 14 of 15 patients showed $2.47{\pm}2.00$ sentinel lymph nodes. On intraoperative gamma probe, $2.36{\pm}1.96$ sentinel lymph nodes were detected. In 7 patients with positive results of sentinel lymph node metastasis, 5 patients showed positive results of axillary lymph node (sensitivity: 72%) but two did not. In 7 patients with negative results of sentinel lymph node metastasis, all axillary nodes were free of disease (specificity: 100%). Conclusion: Sentinel lymph node biopsy with lymphoscintigraphy and intraoperative gamma probe is a reliable method to predict axillary lymph node metastasis in breast cancer, and unnecessary axillary lymph node dissection can be avoided.

  • PDF

A Lower Bound Estimation on the Number of Micro-Registers in Time-Multiplexed FPGA Synthesis (시분할 FPGA 합성에서 마이크로 레지스터 개수에 대한 하한 추정 기법)

  • 엄성용
    • Journal of KIISE:Computer Systems and Theory
    • /
    • v.30 no.9
    • /
    • pp.512-522
    • /
    • 2003
  • For a time-multiplexed FPGA, a circuit is partitioned into several subcircuits, so that they temporally share the same physical FPGA device by hardware reconfiguration. In these architectures, all the hardware reconfiguration information called contexts are generated and downloaded into the chip, and then the pre-scheduled context switches occur properly and timely. Typically, the size of the chip required to implement the circuit depends on both the maximum number of the LUT blocks required to implement the function of each subcircuit and the maximum number of micro-registers to store results over context switches in the same time. Therefore, many partitioning or synthesis methods try to minimize these two factors. In this paper, we present a new estimation technique to find the lower bound on the number of micro-registers which can be obtained by any synthesis methods, respectively, without performing any actual synthesis and/or design space exploration. The lower bound estimation is very important in sense that it greatly helps to evaluate the results of the previous work and even the future work. If the estimated lower bound exactly matches the actual number in the actual design result, we can say that the result is guaranteed to be optimal. In contrast, if they do not match, the following two cases are expected: we might estimate a better (more exact) lower bound or we find a new synthesis result better than those of the previous work. Our experimental results show that there are some differences between the numbers of micro-registers and our estimated lower bounds. One reason for these differences seems that our estimation tries to estimate the result with the minimum micro-registers among all the possible candidates, regardless of usage of other resources such as LUTs, while the previous work takes into account both LUTs and micro-registers. In addition, it implies that our method may have some limitation on exact estimation due to the complexity of the problem itself in sense that it is much more complicated than LUT estimation and thus needs more improvement, and/or there may exist some other synthesis results better than those of the previous work.

The Influence of Botulinum Toxin Type A Masticatory Efficiency (보툴리눔 A형 독소가 저작효율에 미치는 영향)

  • Park, Hyung-Uk;Kwon, Jeong-Seung;Kim, Seong Taek;Choi, Jong-Hoon;Ahn, Hyung-Joon
    • Journal of Oral Medicine and Pain
    • /
    • v.38 no.1
    • /
    • pp.53-67
    • /
    • 2013
  • This study was aimed to evaluate the masticatory efficiency after botulinum toxin type A (BTX-A) injection during 12 weeks using objective and subjective test. Also, we compared the difference of masticatory efficiency between group that injected into the masseter muscle only (M-group) and group that injected into the masseter and temporalis muscle (M-T group). The mixing ability index (MAI) was used as the objective indicator, and visual analogue scale (VAS) and food intake ability (FIA) index were used as the subjective indicators. It was concluded that masticatory efficiency was significantly lowered after a BTX-A injection into the masticatory muscle, but it gradually recovered in a predictable pattern by the 12 weeks. The disturbance of subjective masticatory efficiency was lasted longer than objective masticatory efficiency. The masticatory efficiency was lower in M-T group than M group. It was statistically significant in the VAS and FIA at 4 weeks, but the MAI showed no significancy. After 4weeks, there was rapid recovery of muscle function in M-T group, and the difference between two groups was not significant. It could be concluded that there will be no serious disturbance of mastication compared to injection is done only into the masseter muscle, even if injection is done into the masseter and temporalis muscle in dose of this study. According to the food properties, it was confirmed that people feel more discomfort on taking hard and tough foods after BTX-A injection and not only hard foods, but also intake of soft and runny foods were influenced by botulinum toxin injection.