• Title/Summary/Keyword: 동력측정장치

Search Result 86, Processing Time 0.02 seconds

The effect of the revolution and forwarding speed of the rotary blade on the tilling power requirement (로우터리 경운(耕耘)날의 회전속도(回轉速度) 및 작업속도(作業速度)가 경운소요동력(耕耘所要動力)에 미치는 영향(影響))

  • Kwon, Soon Goo;Kim, Soung Rai
    • Korean Journal of Agricultural Science
    • /
    • v.11 no.1
    • /
    • pp.160-175
    • /
    • 1984
  • This study was carried out to analyze the effects of the revolution and forwarding speed of the rotary blade and the edge curves which were $30^{\circ}$ and $40^{\circ}$, on the power requirement of rotary tillage. In this study, the revolutions of the rotary blade considered were 204, 243, 285, 360 rpm, and the forwarding speeds of the rotary system considered were 29.40cm/sec, 46.93em/sec. The power requirements of rotary blade were measured by a dynamic strain gage systems at the soil bin which was filled with artificial soil. The results of the study were summarized as follows: 1. The response surface analysis showed that the revolution and forwarding speed of the rotary shaft had an interacting influence on the torque requirement of the rotary blade. The mathematical model developed by the above was repersented as follow. $$T=a_0+a_1V+a_2R +a_3VR+a_4VR^2$$ where, $a_0=constant$ $a_1,\;a_2,\;a_3,\;a_4=coefficients$ V=forwarding speed of the rotary system. (em/sec) R=revolution of the rotary shaft. (rpm) T=tilling torque requirement. (kg-m) 2. When the maximum tilling torque requirement was analyzed, ${\partial}T/{\partial}R$ was decreased with the increasing revolution of rotary shaft, while ${\partial}T/{\partial}V$ was increased, which was minimum at 200~220 rpm. When the forwarding speeds were increased, ${\partial}T/{\partial}R$ was decreased with increasing rate. 3. When the mean tilling torque requirement was analyzed, ${\partial}T/{\partial}V$ was constant at 320~360 rpm and ${\partial}T/{\partial}R$ was decreased with increasing rate along with the increasing revolution of rotary shaft. 4. When the mean tilling torgue requirement per unit volume of soil was analyzed, ${\partial}T/{\partial}V$ was minimum at 270~300 rpm. ${\partial}T/{\partial}R$ for the forwarding speeds of 29.40cm/sec and 46.93cm/sec was same as that for 280~290 rpm. 5. Increasing the edge curves of the rotary blades, the tilling torque requirement was increased. But other studies showed that the smaller the edge curve, the more straw could be wrapped on blades which resulted in increasing torque requirements. Therefore, the edge curve of rotary blade should be considered for the future study.

  • PDF

An Experimental Study of Fuel Economy and Emission Characteristics for a Heavy-Duty DME Bus (대형 DME버스의 연비 및 배기가스 특성에 관한 연구)

  • Oh, Yong-Il;Pyo, Young-Duk;Kwon, Ock-Bae;Beak, Young-Sun;Cho, Sang-Hyun;Lim, Ock-Taeck
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.36 no.4
    • /
    • pp.371-376
    • /
    • 2012
  • The experimental test was conducted for a heavy-duty DME bus in JE-05 exhaust gas test mode using a chassis dynamometer, exhaust gas analyzers, and a PM measurement system. The heavy-duty DME bus was not equipped with after-treatment systems such as DOC or DPF. The dynamic behavior, emission characteristics, and fuel economy of the bus were investigated with an 8.0-liter, 6-cylinder conventional diesel engine. The results showed that the dynamic behavior in DME mode was almost the same as in diesel mode. However, there was little difference among the two operation modes for $NO_x$ and CO emissions. THC emissions were lower for DME mode than for diesel mode. Also, the amount of PM emissions was remarkably lower than for the diesel mode because DME contains a greater amount of oxygen than diesel. The data showed that $CO_2$ emissions were almost similar in the two modes but fuel economy (calculated using heating value) was lower for DME mode than for diesel mode.

A Study on Characteristics of Drag Reduction Additive under High Temperature Range (고온영역에서 계면활성제의 마찰저감 성능 특성에 관한 연구)

  • Cho, Sung-Hwan;Ryu, Jae-Sung;Jung, Sang-Hoon
    • Journal of Energy Engineering
    • /
    • v.19 no.2
    • /
    • pp.116-120
    • /
    • 2010
  • Overall total length of hydraulic pipe to transport the hot water in the domestic district heating network is above 3,000 Km approximately. This long pipe network requires a lots of the transport pumping power by surface friction of fluid. In this study, the drag reduction(DR) of Amin Oxide $C_{18}$ as non-ionic surfactant according to the fluid velocity, temperature and surfactant concentration under the condition of above $80^{\circ}C$ fluid temperature were investigated experimentally. Results showed that new amin oxide $C_{18}$ surfactant had DR of maximum 30% in fluid temperature of $80^{\circ}C$ and had 15% DR in fluid temperature over $100^{\circ}$ under short time test condition. And amine oxide had 155 hours duration time to keep the DR characteristic in the fluid temperature of $80^{\circ}$ and 1000 ppm concentration. But duration time of DR was decreased when fluid temperature increased.

The Characteristics Study of Vehicle Evaporative Emission and Performance according to the Bio-Fuel Application (바이오 연료 적용에 따른 차량 증발가스 및 성능특성 연구)

  • Noh, Kyeong-Ha;Lee, Min-Ho;Kim, Ki-Ho;Kim, Sin;Park, Cheon-Kyu
    • Journal of the Korean Applied Science and Technology
    • /
    • v.34 no.4
    • /
    • pp.874-882
    • /
    • 2017
  • As the interest on the air-pollution is gradually rising up at home and abroad, automotiv e and fuel researchers have been working on the exhaust emission reduction from vehicles through a lot of approaches, which consist of new engine design, innovative after-treatment systems, using clean (eco-friendly alternative) fuels and fuel quality improvement. This research has brought forward three main issues : evaporative, performance, air pollution. In addition, researcher studied the environment problems of the bio-ethanol, bio-butanol, bio-ETBE (Ethyl Tertiary Butyl Ether), MTBE (Methyl Tert iary Butyl Ether) fuel contained in the fuel as octane number improver. The researchers have many dat a about the health effects of ingestion of octane number improver. However, the data support the con clusion that octane number improver is a potential human carcinogen at high doses. Based on the bio-fuel and octane number improver types (bio-ethanol, bio-butanol, bio-ETBE, MTBE), this paper dis cussed the influence of gasoline fuel properties on the evaporative emission characteristics. Also, this p aper assessed the acceleration and power performance of gasoline vehicle for the bio-fuel property. As a result of the experiment, it was found that all the test fuels meet the domestic exhaust gas standards, and as a result of measurement of the vapor pressure of the test fuels, the bio - ethanol : 15 kPa and the biobutanol : 1.6 kPa. thus when manufacturing E3 fuel, Increasing the biobutanol content reduces evaporation gas and vapor pressure. In addition, Similar accelerating and powering performance was shown for the type of biofuel and when bio-butanol and bio-ethanol were compared accelerated perf ormance was improved by about 3.9% and vehicle power by 0.8%.

Study on Nozzle Type and Proper Discharge Pressure of Sprayer for Vehicle Disinfecting System (차량소독장치용 노즐형태와 분무기의 적정토출압력에 관한 연구)

  • Lim, Young-Il;Chang, Dong-Il;Kim, Jeong-Chul;Park, Dong-Suk;Lee, Seung-Joo;Kang, Beom-Sun;Kim, Suk;Gutierrez, Winson M.;Lee, Tae-Hoon;Choi, Chung-Heon;Chang, Hong-Hee
    • Journal of agriculture & life science
    • /
    • v.50 no.3
    • /
    • pp.119-127
    • /
    • 2016
  • The current disinfection method of vehicles being applied in South Korea has various shortcomings. So, the epidemic has generated continuously at livestock farms. It is very important to develop an effective disinfection system for reduction of the epidemic. And various basic data is required for this development. Therefore, this study was performed to identify the nozzle type and proper discharge pressure of sprayers. The experiment was conducted from January 10, 2012 until February 28, 2012. All the performance measurement experiments were repeated five times. The subjects of experiment were the A, B and C company's products. The sprayed capacity, angle of spray and the covering area ratio were measured for each product. As a result, the sprayed capacity, angle of spray and the covering area ratio were increased as the discharge pressure of the sprayer was increased. In conclusion, the conical shaped of the nozzle is considered more appropriate than V-shaped, and the proper discharge pressure is expected to be at least 20kg/㎠.

Effect of Cooling Water Capacity on the Engine Performance for Small Diesel Engine (냉각수(冷却水) 용량(容量)이 소형(小型) 디젤기관(機關)의 성능(性能)에 미치는 영향(影響))

  • Myung, Byung Soo;Kim, Soung Rai
    • Korean Journal of Agricultural Science
    • /
    • v.13 no.2
    • /
    • pp.265-278
    • /
    • 1986
  • This study was attempted to improve the thermal efficiency of 6 kW water-cooled diesel engine on power tiller. The engine performance tests were conducted to find out the effect of cooling water capacity of 2700cc, 2800cc, 2900cc, 3000cc, 3100cc on power, brake specific fuel consumption (BSFC), torque, temperature of cooling water and lubricating oil and friction losses of the engine with D. C. dynamometer. The results obtained in the study are summarized as follows: 1. The performance of the engine tested was adequated to Korea Industrial Standard but actual economy power was 10% higher than the labeled rated power of the engine. The BSFC of the engine tested 297.8g/kW-h which is belong a little higher level than hreign products. The temperature of cooling water was $101^{\circ}C$ which is higher than SAE standard ($88^{\circ}C$) 2. The friction losses of engine tested was 3.656 kW at 2200 rpm of rated rpm (piston speed 6.97m/sec) and is higher than those of foreign products. 3. When the cooling water capacity was increased from 2700cc to 3100cc the power output of the engine was increased from 6.7 kW to 7.13 kW at the rate of 6.4% and also the torque of the engine was increased from 28.85 N.m to 30.76 N.m at the rate of 6.39%. 4. When the cooling water capacity was increased from 2700cc to 3100cc, the BSFC was decreased 6.9g/kW-h from 310.9g/kW-h to 304.1g/kW-h, and after one half hour operation with full load, the temperature of cooling water was decreased $13^{\circ}C$ from $101^{\circ}C$ to $88^{\circ}C$ and also the temperature of lubricant oil was decreased $6.4^{\circ}C$ from $76.7^{\circ}C$ to $70.4^{\circ}C$. 5. The mechanical efficiency was increased from 70.08% to 71.08% when the cooling water capacity was increased from 2700cc to 3100cc.

  • PDF