• Title/Summary/Keyword: 동공크기

Search Result 108, Processing Time 0.03 seconds

Analysis of Variation in Pupil Size of Elementary Students on the Types of Generating Scientific Hypothesis (과학적 가설 생성 유형에 따른 초등학생의 동공크기 변화 분석)

  • Choi, Sungkyun;Shin, Donghoon
    • Journal of The Korean Association For Science Education
    • /
    • v.37 no.3
    • /
    • pp.483-492
    • /
    • 2017
  • The purpose of this study is to analyze the variation in pupil size as shown in the scientific hypothesis generation process of students in Elementary School. The subjects for research consisted of 20 fifth-year students at Seoul B elementary school who agreed to participate in the research. The task consisted of four scientific hypothesis-generating tasks. SMI's Eye Tracker(iView $X^{TM}$ RED) was used to collect eye movement data. Experiment 3.6 and BeGaze 3.6 softwares were used to plan experiment and analyzed the task performance process and eye movement data. The findings of this study are twofold. First, there were four types that generate hypothesis about the tasks. Second, in the moment of generating hypothesis, participants' pupils have grown bigger. And while thinking of generating hypothesis or elaborating hypothesis, there were no big changes. These results show the moment of generating hypothesis is affected by emotional factors besides cognitive factors.

The Changes in Contrast Sensitivity and Glare Sensitivity when Wearing Circle Contact Lenses after the Refractive Surgery (시력교정술 후 써클콘택트렌즈 착용 시 대비감도 및 눈부심감도 변화)

  • Kwon, Ki Nam;Park, Sang Hee;Kim, So Ra;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.21 no.1
    • /
    • pp.23-34
    • /
    • 2016
  • Purpose: In the present study, the effect of circle contact lenses wear on contrast sensitivity and glare sensitivity in a refractive surgery group was investigated. Methods: The contrast sensitivity and glare sensitivity were evaluated using by CGT-1000 for a non-refractive surgery group as control group(40 eyes) and a refractive surgery group(30 eyes) applied plano circle contact lenses, and pupil size was also measured. The correlation between contrast/glare sensitivity and the pupil size was analyzed. Results: In the refractive surgery group, contrast sensitivity in the range of high spatial frequency decreased with wearing circle contact lenses, and amount of decrease for the refractive surgery group was larger than for the control group. The correlation between pupil size and the change of contrast sensitivity was decreased by wearing circle contact lenses, and the correlation was lower in the refractive surgery group than the control group. Furthermore, the wear of circle contact lenses affected on glare sensitivity. In analyzing the change of glare sensitivity by pupil size, the glare was larger in the refractive surgery group than control group. Circle contact lenses in refractive surgery group were not fitted on the center of cornea. Conclusions: In the present study, it is suggested that the sufficient understanding and consideration about the decrease of contrast sensitivity and the increase of glare by wearing circle contact lenses after the refractive surgery is necessary.

Changes of Refractive Errors Caused by Corneal Shape and Pupil Size (각막지형과 동공크기에 의한 굴절교정값의 변화)

  • Noh, Yeon Soo;Kim, Sang-Yeob;Moon, Byeong-Yeon;Cho, Hyun Gug
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.3
    • /
    • pp.383-387
    • /
    • 2014
  • Purpose: To investigate the effect of corneal unique shape to changes of refractive full corrections when pupil size changes. Methods: Subjective refraction for monocular full correction was performed to 30 subjects ($23.33{\pm}1.78$ of age, 60 eyes) in two room conditions, 760 lx and 2 lx, respectively. Pupillary diameter was measured in two conditions and the change pattern was analyzed using a peak data of corneal topography. Results: Pupillary diameter was 3.74~4.00 mm in 760 lx and 5.52~5.90 mm in 2 lx. By comparison with refractive data in 760 lx, those data in 2 lx was changed as follows: more (-) spherical power of 17 eyes (28.3%), more (+) spherical power of 10 eyes (17.7%), more (-) cylinderical power of 17 eyes (28.8%), less (-) cylinderical power of 9 eyes (15.3%), and astigmatic axis rotation of 36 eyes (62.1%). From peak data of corneal topography, the changing pattern of two principal meridians was classified into 4 types. Conclusions: Expansion of the corneal refractive surface accompanied with pupillary dilation may be a main factor that effects the changing a values of subjective refraction because of unique corneal shape. Therefore, subjective refraction should be performed under the nearest lighting condition to a main living environment.

Effect of Hydrolytic Temperature on Pore Structure of Alkoxide-derived Aluminas (Alkoxide 법으로 합성한 알루미나의 동공구조에 미치는 가수분해 온도의 영향)

  • 조정미;정필조
    • Journal of the Korean Ceramic Society
    • /
    • v.25 no.3
    • /
    • pp.217-224
    • /
    • 1988
  • Pore structures of Alkoxide-derived aluminas are investigated by BET Nitrogen Sorption method. Aluminas are derived from hydrolysis of aluminum isopropoxide at 3$^{\circ}$and 8$0^{\circ}C$ with stoichiometric quantities of water in use. The resulting hydrolysates are then subjected to thermal treatment for a fixed period of time from 200$^{\circ}$to 50$0^{\circ}C$ in gradual fashions. The hydrolysates obtained at 3$^{\circ}C$ increase their pore volumes with increasing heat treatment, exhibiting their pore-size distributio as twinpeaked. In contrast, the reverse is true to the hydrolysates obtained at 8$0^{\circ}C$, showing their pore size distribution as single-peaked. This suggests that the pore shapes of the former shall be slit-shaped, whilst whose as the latter shall be of a ink-bottle shape. All the evidence indicates that the hydrolytic temperatures play an important role not only in determining the pore shapes of the alumina samples, but in controlling the liberation of structural water in the alumina layers. It is also, surmized that the subsequent heat treatment may at best affect the mode of pore size distribution for the resulting alumina product(s).

  • PDF

Corneal Asphericity and Optical Performance after Myopic Laser Refractive Surgery (굴절교정수술을 받은 근시안의 각막 비구면도와 광학적 특성 평가)

  • Kim, Jeong-Mee;Lee, A-Young;Lee, Koon-Ja
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.2
    • /
    • pp.179-186
    • /
    • 2013
  • Purpose: To compare corneal asphericity, visual acuity (VA), and ocular and corneal higher-order aberrations (HOAs) between myopic refractive surgery and emmetropia groups. Methods: Twenty three subjects ($23.0{\pm}2.5$ years) who underwent myopic refractive surgery and twenty emmetropia ($21.0{\pm}206$ years) were enrolled. The subjects'criteria were best unaided monocular VA of 20/20 or better in both two groups. High and low contrast log MAR visual acuities were measured under photopic and mesopic conditions. Corneal and ocular HOAs were measured using Wavefront Analyzer (KR-1W, Topcon) for 4 mm and 6 mm pupils. Corneal asphericity was taken by topography in KR-1W. Results: There was no significant difference in VA between two groups under either photopic or mesopic conditions. In ocular aberrations, there were significant differences in total HOAs, fourthorder and spherical aberration (SA) for a 6 mm between two groups (p=0.045, p<0.001, and p<0.001, respectively). In corneal aberrations, there was a significant difference in SA for 4 mm (p=0.001) and 6 mm (p<0.001) pupils between two groups and there were statistically significant differences in total HOAs (p<0.001) and fourth-order aberrations (p<0.001) between two groups for a 6 mm pupil. There was a significant correlation in emmetropia between Q-value and SA in ocular aberrations for 4 mm and 6 mm pupils (r=0.442, p=0.004, and r=0.519, p<0.001) and in corneal aberrations for 4 mm and 6 mm pupils (r=0.358, p=0.023, and r=0.646, p<0.001). No significant correlations were found between Q-value and SA in refractive surgery group. Conclusions: VA in myopic refractive surgery is better than or similar to emmetropia. Nevertheless, the more increasing pupil size is, the more increasing aberrations are. Thus, it could have an influence on the quality of vision at night.

Video Summarization Using Eye Tracking and Electroencephalogram (EEG) Data (시선추적-뇌파 기반의 비디오 요약 생성 방안 연구)

  • Kim, Hyun-Hee;Kim, Yong-Ho
    • Journal of the Korean Society for Library and Information Science
    • /
    • v.56 no.1
    • /
    • pp.95-117
    • /
    • 2022
  • This study developed and evaluated audio-visual (AV) semantics-based video summarization methods using eye tracking and electroencephalography (EEG) data. For this study, twenty-seven university students participated in eye tracking and EEG experiments. The evaluation results showed that the average recall rate (0.73) of using both EEG and pupil diameter data for the construction of a video summary was higher than that (0.50) of using EEG data or that (0.68) of using pupil diameter data. In addition, this study reported that the reasons why the average recall (0.57) of the AV semantics-based personalized video summaries was lower than that (0.69) of the AV semantics-based generic video summaries. The differences and characteristics between the AV semantics-based video summarization methods and the text semantics-based video summarization methods were compared and analyzed.

The Evaluation of Visual Quality by Employing Double-pass Principle in Circle Contact Lens Wearers after Refractive Surgery (시력교정술 후 써클콘택트렌즈 착용시 double-pass 원리를 이용한 시력의 질 평가)

  • Kwon, Ki Nam;Kim, So Ra;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.3
    • /
    • pp.277-284
    • /
    • 2015
  • Purpose: The study aimed to evaluate the effect of circle contact lens wearing on visual quality of the eyes after a refractive surgery. Methods: The objective visual quality was evaluated for 40 eyes who did not get refractive surgery and 30 eyes who got a refractive surgery after applying plano circle contact lenses on their eyes, respectively. Modulation transfer function (MTF), objective scatter index (OSI) and the focusing ratio on retina (Strehl ratio) were measured by using optical quality analysis system (OQAS) and the correlation between pupil size and objective visual quality was analyzed by measuring the pupil size. Results: When wearing circle contact lens on the eyes after refractive surgery, MTF and Strehl ratio were reduced and OSI was increased compared with the eyes without refractive surgery. The eyes after a refractive surgery showed more significant difference changes in MTF, OSI and Strehl ratio according to the pupil size compared with those without refractive surgery. Conclusions: The results showed that wearing of circle contact lens after the refractive surgery has deteriorated the objective visual quality based on the quality of focused image on the retina. Therefore, we suggest that sufficient understanding and consideration about the deterioration of visual quality is necessary in the case of circle contact lens wearing after refractive surgery.

The Study of Kinetic Visual Acuity in College Students (대학생의 동적시력에 관한 연구)

  • Shim, Moon-Sik;Kim, Sang-Hyun;Kang, Hye-Sook;Shim, Hyun-Suk
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.17 no.4
    • /
    • pp.419-424
    • /
    • 2012
  • Purpose: We were to obtain the basic data for studying kinetic visual acuity through the comparative analysis in kinetic visual acuity, visual acuity, refractive error, pupil size, and hand reaction time for college students. Methods: We had tested the kinetic visual acuity, visual acuity, refractive error and hand reaction time using the kinetic visual acuity tester (KOWA AS-4A), the hand reaction time program and auto-refractometer for thirty-nine male and same female optometry students with more than +0.1 LogMAR visual acuity in both eyes. And the results were examined gender differences of kinetic visual acuity and the factors correlation. Results: In the measured values of male, pupil size were 6.00 mm, hand reaction time 0.23 msec, refractive error -1.66 D, visual acuity -0.07, kinetic visual acuity 0.59 and pupil size 5.86 mm, hand reaction time 0.24 msec, refractive error -2.08 D, visual acuity -0.02, kinetic visual acuity 0.46 in female. It was significant difference for kinetic visual acuity values but other factors were not. The kinetic visual acuity and left visual acuity had the highest correlation, r=-0.406. The kinetic visual acuity indicated more excellent values in the case of increasing visual acuity and decreasing myopia amount. Conclusions: It was able to see that male college students were better than female for kinetic visual acuity and the visual acuity were related to kinetic visual acuity.

Pupil Data Measurement and Social Emotion Inference Technology by using Smart Glasses (스마트 글래스를 활용한 동공 데이터 수집과 사회 감성 추정 기술)

  • Lee, Dong Won;Mun, Sungchul;Park, Sangin;Kim, Hwan-jin;Whang, Mincheol
    • Journal of Broadcast Engineering
    • /
    • v.25 no.6
    • /
    • pp.973-979
    • /
    • 2020
  • This study aims to objectively and quantitatively determine the social emotion of empathy by collecting pupillary response. 52 subjects (26 men and 26 women) voluntarily participated in the experiment. After the measurement of the reference of 30 seconds, the experiment was divided into the task of imitation and spontaneously self-expression. The two subjects were interacted through facial expressions, and the pupil images were recorded. The pupil data was processed through binarization and circular edge detection algorithm, and outlier detection and removal technique was used to reject eye-blinking. The pupil size according to the empathy was confirmed for statistical significance with test of normality and independent sample t-test. Statistical analysis results, the pupil size was significantly different between empathy (M ± SD = 0.050 ± 1.817)) and non-empathy (M ± SD = 1.659 ± 1.514) condition (t(92) = -4.629, p = 0.000). The rule of empathy according to the pupil size was defined through discriminant analysis, and the rule was verified (Estimation accuracy: 75%) new 12 subjects (6 men and 6 women, mean age ± SD = 22.84 ± 1.57 years). The method proposed in this study is non-contact camera technology and is expected to be utilized in various virtual reality with smart glasses.

Pupil tracking using Hybrid camera setup for Subhologram display (서브 홀로그램 디스플레이를 위한 하이브리드 카메라 기반 동공 추적)

  • Choo, Hyon-Gon;Park, Min-Sik;Kim, Hyun Eui;Moon, Kyung Ae;Kim, Jin Woong
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2013.11a
    • /
    • pp.112-113
    • /
    • 2013
  • 서브 홀로그램 디스플레이는 디지털 홀로그래피 디스플레이의 제한된 시역을 관찰자의 동공 크기로 맞게 구현하여 사용자가 더 넓은 범위에서 더 큰 영상을 느끼도록 만드는 홀로그래픽 디스플레이이다. 본 논문에서는 서브홀로그램 방식에서 시야 창 문제를 해결하기 위해, Depth 카메라와 스테레오 카메라의 하이브리드 구성을 이용하여 정밀한 사용자 동공 추적 기법에 대해서 제안한다. 저해상도의 깊이 카메라의 얼굴 인식 정보를 바탕으로 고해상도 스테레오 카메라에서의 얼굴 및 눈의 후보영역을 찾고, 고해상도 스테레오 카메라에서 후보 영역 내의 동공 위치를 잦아서 빠르면서도 정밀한 동공 추적이 가능하도록 하였다.

  • PDF