• Title/Summary/Keyword: 동결모래

Search Result 27, Processing Time 0.022 seconds

Field Appliciability Evaluation of Eco-friendly Mixed Soil (친환경 혼합토의 현장적용성 평가)

  • Park, Kyungsik;Oh, Sewook;Bae, Wooseok
    • Journal of the Korean GEO-environmental Society
    • /
    • v.15 no.2
    • /
    • pp.17-25
    • /
    • 2014
  • In the present study, it were performed an unconfined compression test and a field applicability test according to a mixed ratio of SS, soil type and curing period to analyze strength and deformation characteristic in order to evaluate engineering characteristics of soil mixed pavements using the eco-friendly soil stabilizer (SS). The test results revealed that SS mixed soil shows fast strength development at the initial curing time while 28-day strength amounted for 97% of the final strength. Furthermore, coarse-grained dredged sand (DS) and weathered granitic soil (WGS) have a larger ratio of deformation coefficient with respect to unconfined compressive strength than fine-grained dredged clay (DC) and organic soil (OS). Moreover, a comparison test between natural and forced drying conditions was conducted and test result showed 54% to 67% of strength degradation while having 55% to 63% of strength degradation in the freezing and thawing test result. Finally, a repeated loading test result showed that DS experiences up to 35% of strength reduction compared to initial strength under 10,000 times loading in maximum. Thus, it was validated that an appropriate amount of fine-grained sand is necessary to secure resistance capability to repeated loading.

The Study of Appropriate Mixture Ratio and Replacement Ratio of Bottom Ash Mixture Compaction Pile in Soft Ground (연약지반에서 저회혼합다짐말뚝의 적정 혼합비 및 치환율 산정에 관한 연구)

  • Do, Jong Nam;Chu, Ick Chan;Chae, Hwi Young;Chun, Byung Sik
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.32 no.4C
    • /
    • pp.139-147
    • /
    • 2012
  • In this study, various laboratory tests using bottom ash, which has similar engineering properties with sand, were conducted in order to solve the problem of clogging in granular compaction pile and to address sand supply and demand. In particular, testing was performed to help reduce clogging and minimize voids in a crushed stone compaction pile constructed in soft ground. Based on compaction tests and large diameter direct shear tests, an optimum mixing ratio was determined to be 80:20 (crushed stone to bottom ash) because an 80:20 mixing ratio showed the highest shear strength. Test results showed that as the bottom ash content increased above 20%, internal friction angle decreased. Another test method showed freezing and thawing had little effect when the replacement ratio was over 40%. Therefore, bottom ash mixed compaction piles in soft ground are most economical at a 40% replacement ratio.

A Study on the Development Lightweight Aggregate using Clink Ash for Reduction in Freezing Ground (지반의 동결저감 대책기술을 수립하기 위한 클링커애쉬 인공경량골재 개발에 관한 연구)

  • Moon, Jong-Wook
    • Fire Science and Engineering
    • /
    • v.23 no.6
    • /
    • pp.116-125
    • /
    • 2009
  • This study is progressed function ratio, it's trued taste by an experiment to present data for human work light weight aggregate development that use clink ash progressed liquid limit, small success limit, wear loss in quantity, sand equivalent, sieve cutting examination. 80 : 20's match of function rain examination is 1.4, and that use rubble Goljae as ckink ash lightweight aggregate's capacity ratio increases by 1.0 increase of function rain many. Also, examination multiplied delicate flavor gradually according to increase of the mixing rate, and absorption coefficient increased. This is judged by phenomenon that appear by special quality upper clink ash of polystyrene bid and porosity's increase between lightweight aggregate. It is case that use aggregate of wear loss in quantity is 13.5 in sand equivalent and a wear loss in quantity experiment and although case that mix 20% increases by 14.4, this phenomenon by weak tissue of lightweight aggergate be judge. When it's as a these experiment, the statue prevention floor of a street improvement specifications is prescribing so that satisfy by sand equivalent 20, CBR 10. This is showed result that this satisfies in quality standard all in match experiment ago that see.

Permeability Reduction of Soils by Biomass Injection (미생물 균체의 주입을 통한 토양의 투수계수 감소)

  • 송영우;김건하;구동영
    • Journal of the Korean Geotechnical Society
    • /
    • v.15 no.6
    • /
    • pp.273-283
    • /
    • 1999
  • When microorganism is injected into porous medium such as soils, biomass is retained in the pore. Soil pore size and shape are varied from the initial condition as a result of biofilm formation which makes hydraulic conductivity reduced and friction rate between soil aggregates increased. In this research, hydraulic conductivity reduction was measured after microorganism are inoculated and cultured with synthetic substrate and nutrient. In addition, this research evaluated the applicability of biomass-soil mixture to the field condition as an alternative cover material in landfill by measuring hydraulic conductivity change after repetitive freeze-thaw cycles. Hydraulic conductivity of silty soil decreased by approximately 1/50 after biomass inoculation and cultivation. Biofilm attached on soil aggregates is resistant to acidic or basic condition. After repetitive freeze-thaw cycles, however, hydraulic conductivity increase implies that biomass clogging can be impaired.

  • PDF

Field Application and Maintenance of sidewalk concrete block for PV Power Generation (태양광 발전을 위한 보도형 콘크리트 블록의 현장 적용과 유지관리)

  • Kim, Bong-Kyun;Kim, Yun-Yong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.23 no.5
    • /
    • pp.75-83
    • /
    • 2019
  • In order to fulfill the obligation to voluntarily reduce greenhouse gas emissions under the Paris Climate Agreement, the proportion of coal and nuclear power generation is reduced worldwide and national efforts are being made to spread renewable energy including solar power generation. Korea also intends to increase the proportion of renewable energy generation to 30~35% by 2040 by introducing laws and regulations. In addition, while the country is trying to apply solar power generation to sidewalks and roads, there is no research related to it in Korea. Therefore, as a precedent study to develop solar power generation roads, solar power generation concrete blocks applicable to sidewalks and plazas were developed and the applicability was evaluated by constructing them on the site. As a result of indoor experiment, compressive strength was measured by 25.5~35.7MPa and flexural strength was measured by 5.1~10.5MPa, which showed that all domestic standards were satisfied. However, the higher the unit cement amount, the lower the strength was measured according to the mixing of the broken fine aggregate. The absorption rate was 5.7%, which satisfied the domestic standard of 7% or less. As a result of the freeze-thawing test, the reduction rate of the compressive strength after 100 cycles was up to 6.3%. As a result of measuring the settlement amount after construction, the maximum of 2.498mm was measured and irregular settlement occurred in the overall area, which is because the resolution of the sand layer was poor during construction. Maintenance techniques of sidewalk concrete block and solar panel need to be established more efficiently through long-term operation in the further.

A Study on the Basic and Compression Characteristics of Lightweight Waste for Use as Fill Materials (성토재 적용을 위한 경량폐기물의 기본물성 및 압축특성 연구)

  • Lee, Sung-Jin;Kim, Yun-Ki;Koh, Tae-Hoon;Lee, Su-Hyung;Shin, Min-Ho
    • Journal of the Korean Geotechnical Society
    • /
    • v.27 no.5
    • /
    • pp.61-74
    • /
    • 2011
  • This is a fundamental research on use as fill material of lightweight waste such as bottom ash and tire shred. We carried out the test for particle size distribution, specific gravity, density, shear strength, permeability and vertical compression settlement, considering water content change and temperature effect of several waste materials. Bottom ash, which is lighter than soils, has similar permeability and particle size distribution to those of weathered soils. But permeability may differ depending on the particle size distribution. The shear strength aspect of bottom ash and tire shred mixed materials are similar to that of natural fill materials. In the 1-D vertical compression settlement test, we could be assured that bottom ash and tire shred mixed materials showed similar compression settlement to that of sand under actual vertical stress. Furthermore, materials including bottom ash showed smaller compression settlement than that of weathered soils in the long-term settlement test under wetting and freezing-thawing condition.

Assessment of the Correlation between Segregation Potential and Hydraulic Conductivity with Fines Fraction (세립분 함유량에 따른 동상민감성 지수와 수리전도도의 상관관계 평가)

  • Jin, Hyunwoo;Kim, Incheol;Eun, Jongwan;Ryu, Byung Hyun;Lee, Jangguen
    • Journal of the Korean Geotechnical Society
    • /
    • v.37 no.12
    • /
    • pp.47-56
    • /
    • 2021
  • The cryosuction (negative pore pressure) in freezing soils causes groundwater migration from the frozen fringe to freezing front for ice lens formation. Frost heave and heaving pressure by ice lens cause damage to ground infrastructure. In order to prevent damage by the frost heave, various frost susceptibility criteria have been proposed. The SP (Segregation Potential) is the most widely used classification criterion for frost susceptibility in cold regions. The expansion of the ice lens by the migration of the groundwater is a key role in frost heave mechanism, and thus it is necessary to evaluate the hydraulic conductivity. In this paper, soil mixtures of coarse-fines (sand-silt) were prepared in various weight fractions and used for frost heave and column permeability test. For each case, the SP and the hydraulic conductivity were derived and correlations were analyzed. As a results, the transition threshold of the SP and the hydraulic conductivity were shown at 20% and 50% of the silt weight fraction, respectively. Although there are difference between these transition thresholds, these two coefficients show a specific correlation. In the future, additional study should be conducted for detailed analysis of the threshold transition values between SP and hydraulic conductivity.