A Study on An Integrated GEO/TES with Geothermal Heat Exchanger and Thermal Ice Storage (지중열 교환기와 빙축열조(Thermal Ice Storage)를 연계시킨 통합 지중열-빙축열조 시스템(Integrated GEO/TES))

  • Lohrenz ED.;Hahn Jeongsang;Han Hyuk Sang;Hahn Chan;Kim Hyoung Soo
    • Economic and Environmental Geology
    • /
    • v.38 no.6 s.175
    • /
    • pp.717-729
    • /
    • 2005
  • Peak cooling load of large buildings is generally greater than their peak heating load. Internal and solar heat gains are used fur selection of adquate equipment in large building in cold winter climate like Canada and even Korea. The cost of geothermal heat exchanger to meet the cooling loads can increase the initial cost of ground source heat pump system to the extend less costly conventional system often chosen. Thermal ice storage system has been used for many years in Korea to reduce chiller capacity and shift Peak electrical time and demand. A distribution system designed to take advantage of heat extracted from the ice, and use of geothermal loop (geothermal heat exchanger) to heat as an alternate heat source and sink is well known to provide many benifits. The use of thermal energy storage (TES) reduces the heat pump capacity and peak cooling load needed in large building by as much as 40 to $60\%$ with less mechanical equipment and less space for mechanical room. Additionally TES can reduce the size and cost of the geothermal loop by 1/3 to 1/4 compared to ground coupled heat pump system that is designed to meet the peak heating and cooling load and also can eliminate difficuties of geothermal loop installation such as space requirements and thermal conditions of soil and rock at the urban area.

A study on the comparison by the methods of estimating the relaxation load of SEM-pile (SEM파일의 이완하중 산정방법별 이완하중량 비교 연구)

  • Kim, Hyeong-Gyu;Park, Eun-Hyung;Cho, Kook-Hwan
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.20 no.3
    • /
    • pp.543-560
    • /
    • 2018
  • With the increased development in downtown underground space facilities that vertically cross under a railway at a shallow depth, the demand for non-open cut method is increasing. However, most construction sites still adopt the pipe roof method, where medium and large diameter steel pipes are pressed in to form a roof, enabling excavation of the inside space. Among the many factors that influence the loosening region and loads that occur while pressing in steel pipes, the size of the pipe has the largest impact, and this factor may correspond to the magnitude of load applied to the underground structure inside the steel pipe roof. The super equilibrium method (SEM) has been developed to minimize ground disturbance and loosening load, and uses small diameter pipes of approximately 114 mm instead of conventional medium and large diameter pipes. This small diameter steel pipe is called an SEM pile. After SEM piles are pressed in and the grouting reinforcement is constructed, a crossing structure is pressed in by using a hydraulic jack without ground subsidence or heaving. The SEM pile, which plays the role of timbering, is a fore-poling pile of approximately 5 m length that prevents ground collapse and supports surface load during excavation of toe part. The loosening region should be adequately calculated to estimate the spacing and construction length of the piles and stiffness of members. In this paper, we conducted a comparative analysis of calculations of loosening load that occurs during the press-in of SEM pile to obtain an optimal design of SEM. We analyzed the influence of factors in main theoretical and empirical formulas applied for calculating loosening regions, and carried out FEM analysis to see an appropriate loosening load to the SEM pile. In order to estimate the soil loosening caused by actual SEM-pile indentation and excavation, a steel pipe indentation reduction model test was conducted. Soil subsidence and soil loosening were investigated quantitatively according to soil/steel pipe (H/D).

Study on the structure of the articulation jack and skin plate of the sharp curve section shield TBM in numerical analysis (수치해석을 통한 급곡선 구간 Shield TBM의 중절잭 및 스킨플레이트 구조에 관한 연구)

  • Kang, Sin-Hyun;Kim, Dong-Ho;Kim, Hun-Tae;Song, Seung-Woo
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.19 no.3
    • /
    • pp.421-435
    • /
    • 2017
  • Recently, due to the saturation of ground structures and the overpopulation of pipeline facilities requires to development of underground structures as an alternative to ground structures. Thus, mechanized tunnel construction of the shield TBM method has been increasing in order to prevent vibration and noise problems in construction of the NATM tunnel for the urban infrastructure construction. Tunnel construction plan for the tunnel line should be formed in a sharp curve to avoid building foundation and underground structures and it is inevitable to develop a shield TBM technology that suits the sharp curve tunnel construction. Therefore, this study is about the structural stability technology of the articulation jack, shield jack and skin plate for the shield TBM thrust in case of the mechanized tunnel construction that is a straight and sharp curve line. The construction case study and shield TBM operation principle are examined and analyzed by the theoretical approach. The torque of the cutter head, the thrust of the articulation jack and the shield jack, the amount of over cutting for curve is important respectively in shield TBM construction of straight and sharp curve line. In addition, it is very important to secure the stability of the skin plate structure to ensure the safety of the inside worker. This study examines the general structure and construction of the equipment, experimental simulation was carried out through numerical analysis to examine the main factors and structural stability of the skin plate structure. The structural stability of the skin plate was evaluated and optimizes the shape by comparing the loads of the articulation jack by selecting the virtual soil to be applied in a straight and sharp curve line construction. Since the present structure and operation method of the shield TBM type in domestic constructions are very similar, this study will help to develop the localized shield TBM technology for the new equipment and the vulnerability and stability review.

A Diagnosis of Ecological Health Using a Physical Habitat Assessment and Multimetric Fish Model in Daejeon Stream (물리적 서식지평가기법 및 어류 다변수 평가모델에 의거한 대전천의 생태학적 건강도 진단)

  • Kim, Ja-Hyun;An, Kwang-Guk
    • Korean Journal of Ecology and Environment
    • /
    • v.38 no.3 s.113
    • /
    • pp.361-371
    • /
    • 2005
  • The objective of study was to diagnose integrative ecological health of Daejeon Stream, one of the tributaries of Guem River, during May 2004 ${\sim}$ April 2005. The research approach was primarily based on a Qualitative Habitat Evaluation Index (QHEI) and the Index of Biological Integrity (IBI) using fish assemblage. These outcomes were compared with conventional chemical dataset. For the experiment, four sampling sites were chosen from Daejeon Stream and long-term water quality data during 1995 ${\sim}$ 2004 (obtained from the Ministry of Environment) were analyzed in the spatial and temporal aspects. For the biological health assessment, we developed a stream health assessment model (SHA model) far regional applications. We found that current water quality conditions, based on the COD, BOD, TN and TP, were enhanced by 1.6 ${\sim}$ 5.3 fold over the period of 1995 ${\sim}$ 2004 and that the parameters showed a typical longitudinal decline from the upstream to downstream reach. The differences of water quality between the two reaches were more than 4.4 times, indicating a large spatial variations within the stream. The health conditions, based on the SHA model, averaged 23 and varied from 20 to 26 depending on the sampling stations. Values of the QHEI varied from 39 (Poor condition) to 124 (Cood condition)and values of QHEI in the reach of S2 ${\sim}$ S4 had significantly lower than in the headwater site (S1). Also, biological stream health, based on the criteria of US EPA (1993), was judged as 'Poor condition', in the S4 where TN, TP, BOD and COD were highest. In the meantime, maximum value of SHA (26) was found in the upstream reach (S1) where the water quality and QHEI were best. We also found that compositions of sensitive species showed a linear function with water quality conditions and this pattern was evident in the tolerant species. Thus, the biological stream health, based on the SHA model, matched well water chemistry. Overall outcomes suggest that the biological health impact was a function of chemical degradation and physical habitat quality in the stream.

The implication of capital restructuring on urban development : Chicago politics as the local contingent facter for urban restructuring (자본재구조화가 도시발달에 미치 는 영향:시카고 정치와 재개발사업을 사례로)

  • Koh, Tae Kyung
    • Journal of the Korean Geographical Society
    • /
    • v.29 no.4
    • /
    • pp.420-437
    • /
    • 1994
  • The starting point of the research is the relation between capital restructuring and urban restructuring. The economic restructuring, which has been caused by the economic crisis in the early 1970s in the United States has brought a spatial restructuring at different geographic scales. The degree of the success of urban restructuring is contingent to the local economic and political environments. The local contingent factor such as local politics should not be neglected for investigating the restructuring process. Through the case study of Chicago, the research provides two inconsistencies in applying the structural approach to the local level: first, the lack of the theoretical link between crisis and restructuring; and second, the crucial importance of local politics in shaping urban development.

  • PDF

Feasibility Study for the Reconstruction of Jangan Primary School Building (서울 장안초등학교 재건축 계획 설계 연구 요약)

  • Kim, Seung-Je
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.3 no.3
    • /
    • pp.59-70
    • /
    • 1996
  • 장안초등학교는 한국전쟁 이후인 1955년에 개교된 초등학교이다. 처음에는 8학급의 가교사시설에 18학급으로 편성되어 초기부터 시설이 양적으로 부족하였다. 또한 이 지역의 학생수 증가로 거의 매년에 걸쳐 학급수의 증가와 교실증축이 함께 이루어 졌다. 현재 건물의 건립년도를 살펴보면 1965년 6월에 처음 신관 1층 부분이 건설되어 70년대와 80년대에 걸쳐 꾸준히 증축되어 왔으며, 대지 동측의 별관은 1993년 12월에 건설된 새건물로, 학교교사 건물이 30년된 건물과 최근의 건물이 함께 공존하고 있다. 철근콘크리트 건물이 구조적으로는 100년도 견딘다 하지만 실제로는 약 30년이면 콘크리트의 산성화가 가속화되면서 구조적으로 안전하지 못하다는 학설이 인정되어, 최근 30년이 경과된 학교 건축의 재건축이 사회적 문제로 대두되고 있다. 실제로는 25년이상 경과된 건물에서도 구조적인 하자가 발생하는 예 가 많아 교육부에서는 대체로 25년이상 경과된 건물에 대하여 재건축을 실시하고 있다. 장안초등학교는 20년에서 30년 경과된 건물이 많은 부분을 차지하는 관계로 재건축이 실시되는 예이다. 아직까지 사용이 가능하다고 판단되는 건물은 본관의 남측부분의 교사(1983년 증축)과 신관의 우측부분(1985년 9월 23일 증축)과 별관(1993년 12월 14일 신축)교사동을 들수 있다. 때문에 이 부분에 대하여 철거할 것인가 혹은 그대로 사용할 것인가에 대한 의견이 있어, 최종적으로 별관은 그대로 사용하는 것을 원칙으로 하고 본관 남측부분은 가장 마지막 건설시기에 철거하고 신관 우측부분은 규모가 작아 철거하기로 하였다. 학교건축은 다른 일반건물과는 달리 교육이라는 기능을 충분히 발휘할수 있는 공간구성이 필수적이라 할수 있다. 여기서 말하는 교육이란 예전의 주입식 교육이 아니라 21세기를 바라보는 정보화 세계화를 지향하는 교육으로 학생 개개인의 창의성과 자주성을 발휘시킬수 있는 교육이라는 점에 대하여 의견은 없을 것이다. 이러한 교육이란 다양한 교육방법을 전제로 하며 하나의 학년을 하나의 학습그룹으로 생각하는 것은 중요한 출발점이 될 것이다. 한 학년의 그룹을 교대상의 기본으로하여 이러한 그룹에 대하여 일제학습, 그룹학습, 팀티칭, 개별학습이 이루어 질수 있는 공간을 제공하는 점을 본 장안초등학교 기본계획에서 출발점으로 하였다. 물론 학교전체 학생을 콘트롤할 수 있는 교육방법도 존재한다. 선진 외국의 예를 살펴보면 아동의 능력별 교육을 위하여 무학년제(Non-Grade)를 도입하는 경우도 있지만 아직 우리나라에서는 학급단위가 중요시되고 있다. 이 학급단위는 교육단위이면서 생활지도 단위이기도 하다. 이러한 점을 인식하여 학교건축의 간장 기본 단위가 되는 보통교실 계획을 보통교실과 오픈스페이스를 연속시킨 유니트로 계획하여 일제학습, 그룹학습, 팀티칭, 개별학습 등이 이루어 질수 있도록 하였다. 실제로는 36학급을 계획할 경우, 한학년의 6개 학급이 하나의 공통된 공간내에 그룹핑 되는 것이 바람직하지만(제3안의 배치에서 제안하여 보았지만 북측교실, 오픈스페이스의 통로화등의 문제점이 있었다), 그 규모가 너무 커서 3개학급을 하나의 유니트로 하였다. 물론 한학년이 동일한 층에 배치시켜 서로의 관련성을 높게 하였다. 특별교실 계획은 보통교실과의 관련성과 장래 지역개방의 역할을 고려하여 계획하여야 할 것이다. 장안 초등학교의 경우는 별관을 그대로 사용 한다는 조건이 있기 때문에 기존의 편복도 형식의 교실에서는 보통교실 계획의 어려움이 있어 특별 교실동으로 고려하였다. 때문에 지역개방에 대해서는 문제점을 안고 있다. 체육관은 기준령에는 권장시설로 되어 있지만 학교시설에 필수적인 시설이라 생각한다. 체육은 국민건강에 직결되기 때문이다. 또한 체육관 건설은 실외체육 실내체육에 대응할 뿐 아니라 학교 행사등에 유용히 사용되기 때문에 더욱 필요시설이라 할수 있겠다. 또한 지역개방을 위하여 정문 혹은 후문 가까이에 배치시키는 것은 필수적이다. 별관, 체육관, 운동장, 후문측에 12학급용의 단독건물 등의 기본적인 제약조건을 고려하여 배치하자면 자연히 교실동들이 분산되는 결과를 낳게된다. 이러한 각각의 교사동을 A동을 중심으로 구름다리로 연결하여 동선의 불편함을 해소시켰다. 주차장은 후문 가까이에 약 10정도의 주차공간이 확보가능하다. 이외에는 운동장을 사용하는 방법과 체육관의 1층부분을 필로티로 하여 그곳에 20대 정도 주차시키는 방안이 있다. 주차는 많을수록 편리는 하겠지만 제한된 대지에 모두 만족 시켜주기는 불가능하다. 공공용의 주차와 소방에 필요한 동선이 요구된다. 특히 도심주차난을 생각할 때는 차라리 적극적으로 지하주차장을 계획하는 방안이 있을 것이다. 마지막으로 현재 67학급은 초대형 규모로 초등학교 규모로는 적합하지 못하다. 장래를 고려하여 48학급에서 최종적으로 36학급으로 계획하였으나 한동안은 67학급이 그대로 유지될 것으로 보인다. 신설 초등학교가 가까운 시기에 개교될 것을 기대한다.

  • PDF

Efficient Conservation and Management of Waterside Parks by Promoting Ecology Awareness of Visitors (이용객 생태 인식 증진을 통한 수변공원의 효율적인 보전 및 관리)

  • Choi, Jong Yun;Kim, Seong-Ki;Kim, Jeong-Cheol;Yun, Hak Jong
    • Korean Journal of Environment and Ecology
    • /
    • v.33 no.2
    • /
    • pp.237-251
    • /
    • 2019
  • This study evaluated the ecological value of waterside parks by investigating the animal distribution and ecological feature in 92 waterside parks and analyzed the change of ecological awareness by users and non-users of waterside parks through ecological education and promotion based on the investigation results. The result confirmed inhabitation of various animals including 9 endangered species (Pernis ptilorhynchus orientalis, Accipiter soloensis, Falco subbuteo, Charadrius placidus, Felis bengalensis euptilura, Lutra lutra, Kaloula borealis, Polyphylla laticollis manchurica, and Leptalina unicolor) in waterside parks. Although waterside parks were constructed to be hydrophilic areas for human use, some of them with high natural characteristics are valued as biological habitat. We investigated user status in 5 areas (Daejeon, Sejong, Cheongju, Kongju, and Buyeo) located at Guem river basin to evaluate people's perception of waterside parks and carried out the ecological education and promotion based on the investigation result. The survey of 200 people showed that there were more users of waterside parks than non-users and that people in their 40's showed the highest use rate. The use frequency of waterside parks located in Daejeon and Cheongju was lower than in other areas (Sejong, Kongju, and Buyeo). We considered it was because Daejeon and Cheongju were urban areas and had relatively more leisure areas such as sports facilities and cafe than other areas, and thus the residents had a lower reliance on waterside parks. Moreover, users used waterside parks more frequently when they were nearer to users' residence. It is because most users perceived waterside parks as the leisure sports facility and thus preferred them to be within walking distance. The users' perception of waterside parks as the ecological space "to be preserved" increased after the ecological education and promotion. The change of the perception was higher among users (80%) than non-users (38%). Therefore, ecological education and promotion were potentially more effective to people who user waterside parks and thus had a higher understanding of the characteristics and specification. In conclusion, 1) although waterside parks were constructed for human use, some parts had high ecological value for the distribution of endangered species and outstanding natural beauty, and 2) it is necessary to change the perception of waterside parks from the hydrophilic attribute to the conservation attribute. Such change of perception would contribute to establishing waterside parks that feature both hydrophilic and conservation attributes in the management or upgrading plan of waterside parks in the future.

A study on the fire characteristics according to the installation type of large smoke exhaust port in a small cross sectional tunnel fire (소단면 대심도 터널 화재시 대배기구의 설치형태에 따른 화재특성 연구)

  • Choi, Pan-Gyu;Baek, Doo-San;Yoo, Ji-Oh;Kim, Chang-Yong
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.21 no.1
    • /
    • pp.201-210
    • /
    • 2019
  • Recently, due to the efforts to mitigate traffic congestion and expansion of space efficiency, the construction of underground roads has been increased in big-scale cities. Since tunnels in the city have a higher chance for a fire leading to a great tragedy during a severe traffic jam than mountain tunnels, it is highly likely that it will be constructed as a tunnel, having a small cross section, for small vehicles. However, if they are constructed as such small-vehicle tunnels, it would be possible to reduce the design fire intensity while the concentration of harmful gases would increase due to a reduction in the small cross sectional area, led by a decrease in the tunnel height. In this study, behaviors of fire smoke by the installation interval and format of large-scale exhaust-gas ports were examined and compared in the analysis of temperatures and CO concentrations of a tunnel and its results were as the following. Although there were no significant differences in the smoke spreading distance between installation intervals, but in this study, 100 m was found to be the most effective installation interval. The smoke exhaustion performance was found to be excellent in the order of $4m{\times}3m$, $6m{\times}2m$, and $3m{\times}2m$ (2 lane) of the smoke spreading distance. Although there was no significant difference in the smoke spreading distance between formats of large-scale exhaust-gas ports, it was found that the smoke spreading distance was larger than other cases when it was $3m{\times}2m$ in the fire growing process. The analysis of smoke spreading distances by the aspect ratio showed that a smoke spreading distance was shorted when its the smoke spreading distance was found to be shorter when its traverse distance was relatively longer than its longitudinal distance.