A Comparative Study on the Transition of Purlin Coupling Method of Korean and Chinese Ancient Wooden Constructions (한중 목조건축 도리 결합방식 변천(變遷)에 관한 비교연구)

  • Cha, Ju-hwan
    • Korean Journal of Heritage: History & Science
    • /
    • v.47 no.4
    • /
    • pp.22-47
    • /
    • 2014
  • This study was to understand the basic principles of the East Asian wooden structure system research and analysis. The Korea and China ancient architecture internal structure research that the combination of girders and crossbeams position. The ancient wooden structures of eastern Asian countries, Korea and China are not much different from each other in the principles of the wooden architecture structure, combining pillars, purlins and crossbeams. However, it seems that age-division, local-division, national-division differs in detail techniques. China ancient wooden structures combination of purlin and crossbeam, and So-seul Timber(Chinese name: Chashou叉手, Tuojiao 托脚) seems to show differences according to the age of the fulcrum position, detailed approach is also different according to various historical dynasty. Before in the 15th century, Purlin and Crossbeam are coupled to each other, but since the 15th century, seems to have developed a technique combined with each other Girder and Crossbeam and to prevent buckling of the Crossbeam cross-sectional area increased dramatically. For Tuojiao in China Tang-Wudai dynasty(A.D. 618~979), can see that saw the top position Girder and Tuojiao no direct coupling, can be seen as maintaining the safety of the material than the material of the inner wooden structures prevent buckling of the purlin. Korea ancient wooden structures of Goryeo dynasty(A.D. 918~1391), So-seul Timber(Chinese name Tuojiao) why do not to use the fashion? To use Purlin Lower backing material techniques to prevent buckling is a popular trend to stable can be thought of as a preferred way to maintain. I think that with universality beyond the local-division, national-division and the two countries since the 15th century of Korea and China ancient wooden structures detailed mechanism for the purlin buckling. In middle-late Chosen dynasty, The effect of Deotgeolyi- techniques and fleeting beams reduce the purlin buckling that reduces the load transmitted from purlin and crossbeam of how to reduce the load on the roof portion of the architecture fleeting beams used, which of craftsmanship of the Chosen Dynasty building can be referred to as another technique for preventing buckling purlin. This Korea and China ancient architecture purlin beam structure and material So-seul Timber study. Seems to be able to provide a basic research study to restore and designed the old wooden architectures.

The Experiment for Performance Evaluation of Column-rafter-purlin Connections of an Arch-type Plastic Multi-span Greenhouse (플라스틱 연동온실 기둥-서까래-도리 접합부의 성능 평가 실험)

  • Choi, Man-kwon;Ryu, Hee-ryong;Cho, Myeong-whan;Yu, In-ho;Kim, Seung-yu
    • Journal of Bio-Environment Control
    • /
    • v.29 no.4
    • /
    • pp.473-479
    • /
    • 2020
  • In this study, the structural experiment was conducted with two types of specimens to investigate the mechanical behavior of the column-rafter-purlin connection of an arch-type greenhouse under monotonic loading. Based on the experimental results, the flexural performance was analyzed for two types of connections, and connection classification was attempted. Type B showed 77% of flexural performance compared to Type A, and both types showed that the rigidity and flexural strength did not reach the level of the full rigid. The behavior of the column-rafter-purlin connection was dominated by local buckling due to deformation of the weld and fasteners. As a result of connection classification by AISC standard, both Type A and B connections showed a result that did not meet the rigid connection performance assumed during design, and were classified as simple connection. Therefore, the connection performance evaluation and classification results show that the greenhouse design should be made in consideration of connection performance and in order to design a reliable greenhouse structure, a study on establishing clear design standards for the greenhouse connection is necessary.