• Title/Summary/Keyword: 데이터 획득/처리장치

Search Result 88, Processing Time 0.024 seconds

The fabrication and evaluation of CdS sensor for diagnostic x-ray detector application (진단 X선 검출기 적용을 위한 CdS 센서 제작 및 성능 평가)

  • Park, Ji-Koon;Lee, Mi-Hyun;Choi, Young-Zoon;Jung, Bong-Zae;Choi, Il-Hong;Kang, Sang-Sik
    • Journal of the Korean Society of Radiology
    • /
    • v.4 no.2
    • /
    • pp.21-25
    • /
    • 2010
  • Recently, various semiconductor compounds as radiation detection material have been researched for a diagnostic x-ray detector application. In this paper, we have fabricated the CdS detecton sensor that has good photosensitivity and high x-ray absorption efficiency among other semiconductor compounds, and evaluated the application feasibility by investigating the detection properties about energy range of diagnostic x-ray generator. We have fabricated the line voltage selector(LCV) for a signal acquisition and quantities of CdS sensor, and designed the voltage detection circuit and rectifying circuit. Also, we have used a relative relation algorithm according to x-ray exposure condition, and fabricated the interface board with DAC controller. Performance evaluation was investigated by data processing using ANOVA program from voltage profile characteristics according to resistive change obtained by a tube voltage, tube current, and exposure time that is a exposure condition of x-ray generator. From experimental results, an error rates were reduced according to increasing of a tube voltage and tube current, and a good properties of 6%(at 90 kVp) and 0.4%(at 320 mA) ere showed. and coefficient of determination was 0.98 with relative relation of 1:1. The error rate according to x-ray exposure time showed exponential reduction because of delayed response velocity of CdS material, and the error rate has 2.3% at 320 msec. Finally, the error rate according to x-ray dose is below 10%, and a high relative relation was showed with coefficient of determination of 0.9898.

Development of Dual-mode Signal Processing Module for Multi-slit Prompt-gamma Camera (다중 슬릿 즉발감마선 카메라를 위한 이중모드 신호처리 모듈 개발)

  • Park, Jong Hoon;Lee, Han Rim;Kim, Sung Hun;Kim, Chan Hyeong;Shin, Dong Ho;Lee, Se Byeong;Jeong, Jonh Hwi
    • Progress in Medical Physics
    • /
    • v.27 no.1
    • /
    • pp.37-45
    • /
    • 2016
  • In proton therapy, in vivo proton beam range verification is very important to deliver conformal dose to the target volume and minimize unnecessary dose to normal tissue. For this purpose, a multi-slit prompt-gamma camera module made of 24 scintillation detectors and 24-channel signal processing system is under development. In the present study, we have developed and tested a dual-mode signal processing system, which can operate in the energy calibration mode and the fast data acquisition mode, to process the signals from the 24 scintillation detectors. As a result of performance test, using the energy calibration mode, we were able to perform energy calibration for the 24 scintillation detectors at the same time and determine the discrimination levels for the detector channels. Further, using the fast data acquisition mode, we were able to measure a prompt-gamma distribution induced by a 45 MeV proton beam. The measured prompt gamma distribution was found similar to the proton dose distribution at the distal fall-off region, and the estimated beam range was $17.13{\pm}0.76mm$, which is close to the proton beam range of 16.15 mm measured by an EBT film.

Measurement of Refractive Index Profile of Optical Fiber Using the Diffraction Phase Microscope (회절위상현미경을 이용한 광섬유의 굴절률 프로파일 측정)

  • Jafar-Fard, Mohammad R.;Moon, Sucbei
    • Korean Journal of Optics and Photonics
    • /
    • v.23 no.4
    • /
    • pp.135-142
    • /
    • 2012
  • We have developed a measurement method of the refractive index profile of an optical fiber by using diffraction phase microscopy. In the microscope system, the reference light was extracted directly from the probe light that passed through the sample by means of pinhole filtering with a diffraction grating. The spatial interference pattern produced by the probe light and the reference light was processed to generate the phase image of the sample fiber. The index profile was obtained by the inverse Abel transform of the phase profile. In order to remove the background phase that originated from the index difference between the cladding and the surrounding medium, the background phase was calculated from the phase data of the cladding to make a core phase profile that can be directly transformed to the index profile of the core without the full phase image that includes the entire cladding part.

Design and Simulation of KOMPSAT-3 Payload CCD Clock Driver (다목적실용위성3호 탑재체 CCD 제어클럭 드라이버 설계 및 시뮬레이션)

  • Kim, Young-Sun;Kong, Jong-Pil;Heo, Haeng-Pal;Park, Jong-Euk;Yong, Sang-Soon
    • Aerospace Engineering and Technology
    • /
    • v.8 no.1
    • /
    • pp.49-57
    • /
    • 2009
  • The camera electronics in the KOMPSAT-3 payload provides the several control clocks in order to move the charges, which are converted from the light in the pixel, in the vertical and horizontal direction. Generally, the control clocks depend on the CCD internal design in the system. The KOMPSAT-3 payload uses the CCD controlled by 3-phase vertical clocks and 4-phase timing. The camera generates the various clocks such as the vertical clocks, the horizontal clocks, the summing clocks, the reset clocks and so on. The vertical clocks are deeply related to the camera performance and synchronized with satellite scan-rate even though they are relatively slow. Also, it gives the horizontal clocks without distortion under the very fast pixel-rate. This paper shows the design and simulation of the CCD clocks driver for the KOMPSAT-3 payload.

  • PDF

SAR Test-bed to Acquire Raw Data and Form Real-time Image (실시간 영상형성 및 원시데이터 획득용 SAR 테스트 베드)

  • Shin, Hyun-Ik;Kwon, Kyoung-Il;Yoon, Sang-Ho;Kim, Hyung-Suk;Hwang, Jeonghun;Ko, Young-Chang;You, Eung-Noh;Kim, Jin-Woo
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.20 no.2
    • /
    • pp.181-186
    • /
    • 2017
  • Synthetic aperture radar(SAR) has been widely used for reconnaissance. It provides high-resolution, day-and-night and weather-independent images for a multitude of applications. Because SAR coherently combines many viewing angles to effectively create a large aperture(narrow beam) radar, the test-bed should be capable of moving straightly SAR sensor for the integration angle to meet resolution. This paper describes the test-bed developed to test and evaluate the SAR performance. It forms high-quality images in real time and saves the raw data for the purpose of post processing on the ground.

Neural Network Modeling for Bread Baking Process (제빵 굽기 공정의 신경회로망 모형화)

  • Kim, Seung-Chan;Cho, Seong-In;Chun, Jae-Geun
    • Korean Journal of Food Science and Technology
    • /
    • v.27 no.4
    • /
    • pp.525-531
    • /
    • 1995
  • Three quality factors of bread during baking process were measured to develop neural network models for bread baking process. Firstly, volume and browning changes during bread baking process were measured using image processing technique and temperature changes inside the bread during process were measured by K-type thermocouples. Relationships among them showed nonlinearity. Secondly, multilayer perception structure with error back propagation learning was used to construct neural network models. Three neural network models for volume, browning, and bread temperature were developed respectively. Developed models showed good performance with predictive error of 4.62% for volume and browning changes after 30 seconds, 7.38% for volume and browning changes after 2 minutes, and 1.09% for temperature change inside the bread respectively.

  • PDF

Effect of Detector-Misalignment on TOF-PET Detector Performance (검출기 정렬 오차가 TOF-PET 검출기의 성능에 미치는 영향성 평가)

  • Yang, Jingyu;Kang, Jihoon
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.6
    • /
    • pp.841-846
    • /
    • 2019
  • Effect of misalignment on the performance was evaluated for the development of time-of-flight(TOF)-PET detector. A pair of TOF-PET detector consists of Lutetium-yttrium oxyorthosilicate(LYSO) scintillation crystal with a volume of 3 mm × 3 mm × 20 mm and Geiger-mode avalanche photodiodes(GAPD) photo-sensor with a active area of 3.07 mm × 3.07 mm. Analog output signals from TOF-PET detector were sent to the pre-amplifier and then fed into the gain adjust circuit for achievement of gain homogeneity for each detector. The amplified signals were recorded and digitized by data acquisition system based on oscilloscope. The effect of the detector misalignment between LYSO and GAPD was examined for four different alignment offsets of 0.0 mm, 0.5 mm, 1.0 mm and 1.5 mm for a pair of TOF-PET detector. The photopeak position decreased from ~400 mV to ~250 mV with increasing detector misalignment. the energy resolution and time resolution were degraded from 11.6% to 16.2%, and from 477 ps to 632 ps, respectively. This study demonstrated that PET detector performance was degraded considerably depending on the detector misalignment, which would be a critical issue for the development of TOF-PET detector.

System Development for Measuring Group Engagement in the Art Center (공연장에서 다중 몰입도 측정을 위한 시스템 개발)

  • Ryu, Joon Mo;Choi, Il Young;Choi, Lee Kwon;Kim, Jae Kyeong
    • Journal of Intelligence and Information Systems
    • /
    • v.20 no.3
    • /
    • pp.45-58
    • /
    • 2014
  • The Korean Culture Contents spread out to Worldwide, because the Korean wave is sweeping in the world. The contents stand in the middle of the Korean wave that we are used it. Each country is ongoing to keep their Culture industry improve the national brand and High added value. Performing contents is important factor of arousal in the enterprise industry. To improve high arousal confidence of product and positive attitude by populace is one of important factor by advertiser. Culture contents is the same situation. If culture contents have trusted by everyone, they will give information their around to spread word-of-mouth. So, many researcher study to measure for person's arousal analysis by statistical survey, physiological response, body movement and facial expression. First, Statistical survey has a problem that it is not possible to measure each person's arousal real time and we cannot get good survey result after they watched contents. Second, physiological response should be checked with surround because experimenter sets sensors up their chair or space by each of them. Additionally it is difficult to handle provided amount of information with real time from their sensor. Third, body movement is easy to get their movement from camera but it difficult to set up experimental condition, to measure their body language and to get the meaning. Lastly, many researcher study facial expression. They measures facial expression, eye tracking and face posed. Most of previous studies about arousal and interest are mostly limited to reaction of just one person and they have problems with application multi audiences. They have a particular method, for example they need room light surround, but set limits only one person and special environment condition in the laboratory. Also, we need to measure arousal in the contents, but is difficult to define also it is not easy to collect reaction by audiences immediately. Many audience in the theater watch performance. We suggest the system to measure multi-audience's reaction with real-time during performance. We use difference image analysis method for multi-audience but it weaks a dark field. To overcome dark environment during recoding IR camera can get the photo from dark area. In addition we present Multi-Audience Engagement Index (MAEI) to calculate algorithm which sources from sound, audience' movement and eye tracking value. Algorithm calculates audience arousal from the mobile survey, sound value, audience' reaction and audience eye's tracking. It improves accuracy of Multi-Audience Engagement Index, we compare Multi-Audience Engagement Index with mobile survey. And then it send the result to reporting system and proposal an interested persons. Mobile surveys are easy, fast, and visitors' discomfort can be minimized. Also additional information can be provided mobile advantage. Mobile application to communicate with the database, real-time information on visitors' attitudes focused on the content stored. Database can provide different survey every time based on provided information. The example shown in the survey are as follows: Impressive scene, Satisfied, Touched, Interested, Didn't pay attention and so on. The suggested system is combine as 3 parts. The system consist of three parts, External Device, Server and Internal Device. External Device can record multi-Audience in the dark field with IR camera and sound signal. Also we use survey with mobile application and send the data to ERD Server DB. The Server part's contain contents' data, such as each scene's weights value, group audience weights index, camera control program, algorithm and calculate Multi-Audience Engagement Index. Internal Device presents Multi-Audience Engagement Index with Web UI, print and display field monitor. Our system is test-operated by the Mogencelab in the DMC display exhibition hall which is located in the Sangam Dong, Mapo Gu, Seoul. We have still gotten from visitor daily. If we find this system audience arousal factor with this will be very useful to create contents.