• 제목/요약/키워드: 데시칸트 제습기

검색결과 4건 처리시간 0.021초

실내 빙상장 및 부대시설에 데시칸트 제습기 적용 (Application of Desiccant Dehumidifier on Ice-rink and Subsidiary Facilities)

  • 박승태;방영석;최세영
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2005년도 동계학술발표대회 논문집
    • /
    • pp.533-538
    • /
    • 2005
  • The number of domestic ice-rink is little by little increasing recently. Therefore, the demand for air-conditioning system to adjust adequately the indoor condition of ice-rink is constantly increasing. But, if air-conditioning system for ice-rink isn't designed properly, the problems such as fogging, ice surface condensation, structural deterioration, odors, generation of dew condensation on the surface of a wall occur. The solutions for these problems are to lower the relative humidify of indoor. The objectives of this paper is to apply of desiccant dehumidifier on ice-rink, solve these problems.

  • PDF

하이브리드 데시칸트 선박도장용 제습기 (Hybrid Desiccant Dehumidifier for Shipbuilding Painting)

  • 박승태;금종수;김희재;김동혁
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.248-253
    • /
    • 2009
  • For the energy's effective utilization, the mixed humidifier has been developed and popularized by combining the cooling dehumidifier with the desiccant humidifier properly. This has contributed in many ways to the industry. Hybrid Desiccant Dehumidifier that would be shown in this study could be indispensible in site due to the reduced equipment, with more than 50% reduction in energy.

  • PDF

열펌프, 데시칸트 및 증발식 냉각기를 조합한 하이브리드 냉방 시스템의 동특성 해석 연구 (Dynamic Simulation of a Hybrid Cooling System utilizing Heat Pump, Desiccant and Evaporative Cooler)

  • 서정남;김영일;정광섭
    • 한국지열·수열에너지학회논문집
    • /
    • 제7권1호
    • /
    • pp.45-50
    • /
    • 2011
  • Hybrid desiccant cooling system(HDCS) consists of desiccant rotor, regenerative evaporative cooler, heat pump and district heating hot water coil. In this study, TRNSYS and EES, dynamic and steady simulation programs were used for studying hybrid desiccant cooling system which is applied to an apartment house from June to August. The results show that power consumption of the hybrid desiccant cooling system is 70 kWh in June, 199 kWh in July and 241 kWh in August. Sensible and latent heats removed by the hybrid desiccant cooling system are 300 kWh, 301 kWh in June, 610 kWh, 858 kWh in July and 719 kWh, 1010 kWh in August. COP of the hybrid desiccant cooling system is 8.6 in June, 7.4 in July and 7.2 in August. COP of the hybrid desiccant cooling system decreases when latent heat load increases. Operation time of the system is 70 hours in June, 190 hours in July and 229 hours in August. Since the cooling load is largest in August, the operation time of August is longest for maintaining the indoor temperature at $26^{\circ}C$. Due to the characteristics of hybrid desiccant cooling system for efficiently handling both sensible and latent loads, this system can handle sensible and latent heat loads efficiently in summer.