• 제목/요약/키워드: 덤프밸브(dump valve)

검색결과 4건 처리시간 0.025초

전기체 구조시험의 덤프밸브 조절절차 개발; (Setup Procedure of Dump Valve for Full-Scale Airframe Test)

  • 김성찬;김성준;황인희
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 추계학술대회
    • /
    • pp.1252-1257
    • /
    • 2003
  • This paper present a procedure of meter-out flow control method for dump valve in full-scale airframe test. Emergency stop, which results in dump state, can be happened during full-scale airframe test by several causes. Because servo valve can't control hydraulics actuator in the dump state, pressure in cylinder chamber may rise abruptly and overload can be acted to the test article. In this paper, the procedure and technology of orifice setting are investigated to protect the test article from unexpected loads by dump. The test results show that the presented methods decrease peak loads and improve unloading characteristics of hydraulic actuators in the dump state.

  • PDF

과하중 방지기의 전기체 구조시험 적용에 관한 연구

  • 김성찬;채동철;김성준;황인희
    • 항공우주기술
    • /
    • 제2권2호
    • /
    • pp.11-17
    • /
    • 2003
  • 항공기 전기체 구조시험에 과하중 방지 밸브로 사용되는 미터-아웃방식의 유량제어 방법을 본 보고서로 소개하고자 한다. 전기체 구조시험에서는 여러 요인에 의해 비상시험 중지상태(덤프상태)가 발생하며, 이 상태가 되면 서보밸브의 전원이 차단되어 하중을 가하던 실린더의 양단에 외부조건에 따른 급격한 압력변화가 발생되고, 이 변화는 시험체에 과하중으로 가해진다. 본 연구에서는 덤프로 기인한 하중으로부터 시험체를 보호하기 위해 사용되는 오리피스 면적조절 기술에 대해 소개하였고 실제 시험에서 유압작동기의 덤프특성이 효과적으로 감소되고 있음을 확인하였다.

  • PDF

유압원격제어를 위한 덤프와 감압밸브의 특성에 관한 연구 (A Study on Characteristics of Dump and Reducing Valve for Hydraulic Remote Control System)

  • 오철환;김광;송창섭
    • 한국정밀공학회지
    • /
    • 제5권3호
    • /
    • pp.81-90
    • /
    • 1988
  • In recent, the requirement of remote control of hychaulic system is in- creasing. The actuator unit whose output position is proportional to input electrical signal needs a pressure reducer and a dump valve. The pressure reducer provides a constant regulated pressure and filters contaminants. The dump valve supplies proper pressure to the pressure reducer and unloads when the system is not operated. In this thesis, dump valve and pressure reducer with auxiliary function are studied. The choke in the pressure reducer prevents actuator from supplying higher pressure than necessary pressure at beginning, and the spring constant affects on the dynamic characterisics. In dump valve, it is proved that diameter of servo-slide hold and choke diameter of dump plunger affects on damping response.

  • PDF

원자력발전소 증기발생기 수위제어에 대한 실험적 연구 (An Experimental Study on the Level Control of the Steam Generator in Nuclear Power Plant)

  • 문제선;양명승;김기현;유재석;박영무
    • 에너지공학
    • /
    • 제6권2호
    • /
    • pp.170-175
    • /
    • 1997
  • 본 연구에서는 원자력발전소 내 증기발생기의 원만한 수위제어 향상을 위하여 고리 원자력발전소 모델을 기준으로 Full Linear Scale Down 1/10 크기의 증기발생기 Mock-up을 제작하여 증기 덤프 밸브 개폐시 수위의 수축(shrink), 팽창(swell) 현상을 확인해 보고, 그 원인을 규명하여 보았다. 이와 함께 본 연구를 위하여 개발한 Fuzzy제어기를 이 Mock-up의 제어기로 운용해 봄으로써 제작된 Mock-up이 실제 원자력 발전소 증기발생기의 경우와 같이 수위제어가 가능함을 확인하였고 이에 따라 향후 개발되어질 수 있는 제반 제어기들을 본 Mock-up에 도입, 운용해 봄으로써 제작한 Mock-up의 Simulator로서의 활용 가능성을 실험적으로 검증할 수 있도록 하였다.

  • PDF