Development of Simulation Program of Double Cam Driving System for Rapier Loom (래피어 직기용 더블 캠 구동 시스템의 시뮬레이션 프로그램 개발)

  • Kim, Jong-Su
    • 연구논문집
    • /
    • s.29
    • /
    • pp.111-121
    • /
    • 1999
  • Weft insertion and Beating mechanism which weaves fabric with completion the pattern of warp yarn and weft yarn in the high speed rapier loom is driven by cam operating method. This mechanism has 4 cams on the coaxial line for driving. These cams form a pair by two. and perform a conjugate motion with each other. By this reason, it is necessary for two pairs to realize the synchronized motion through exact and optimal design. From this viewpoint, to analysis the whole cams' movement and to realize the high speed of rapier loom, I tried to develop the computer aided simulation program. In this study, I would like to introduce the simulation program about above-mentioned 4 kinds of cam mechanism which can display the profiles of 2 pairs of cam mechanism not to speak of mutual relationships of their movement on the monitor.

  • PDF

Motion Analysis of the Eccentric Driving Cam on Double Raschel Machine (더블 라셀기 편심캠 구동장치의 운동해석)

  • 권상석;김환국;김영규;전두환
    • Proceedings of the Korean Fiber Society Conference
    • /
    • 2001.10a
    • /
    • pp.147-150
    • /
    • 2001
  • 더블 라셀기(Double Raschel Machine)는 레이스와 메리야스 직물 등을 생산하기 위한 섬유기계로써 대부분의 섬유기계들이 그러하듯이 수많은 링크와 기구들로 이루어져 있다. 따라서, 이러한 복잡한 링크들로 이루어진 기계 구조물을 국산화 개발하기 위해서는 설계오류에 따른 수많은 시행착오와 시간이 소요된다. (중략)

  • PDF

Optimum Design of Beating Cam for High Speed Rapier Loom (고속 래피어 직기용 바듸침 캠의 최적설계)

  • Kim, Jong-Su;Kim, Dae-Won
    • 연구논문집
    • /
    • s.28
    • /
    • pp.89-100
    • /
    • 1998
  • This paper deals with the design and analysis of a beating cam. The beating device of a high speed rapier loom, weaving fabric by completion of warp-weft patterns, is driven by double cam type on the same axis. As the double cam, coupled with two cams, performs the mutual conjugate motion, the double cam must be very preciously designed for smooth. For the shape design of a double cam, an instant velocity center method is proposed. This method can determine the cam profile from the contact conditions of the cam and roller follower and the velocity relationships at the instant velocity center. And the practical applicability was verified by developing “DISKCAM of a CAD program. As the results in this paper, the shapes of two cams, which are in the conjugate motion, are designed by instant velocity center method. We applied 8-order polynominals for the beating as displace¬ment curves for shape determination of double cams. The data of displacement, velocity, and acceleration of beating cam can be used adjust in accurate operation and to develope an advanced beating device.

  • PDF

Digital duplication of provisional prosthesis to fabricate definitive prosthesis for full mouth rehabilitation using double scan technique (잠정수복물의 최종수복물로의 디지털 복제를 통한 완전구강 회복 증례: Double scan technique)

  • Hong, Young-Tack;Koak, Jai-Young;Kim, Seong-Kyun;Heo, Seong-Joo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.1
    • /
    • pp.63-70
    • /
    • 2021
  • Using computer-aided design and manufacturing technique improve quality of treatment in many aspect. This case reports the complete mouth rehabilitation of a patient with amelogenesis imperfecta utilizing digital technology. Clinical examination revealed loss of mastication due to insufficient occlusal stop, missing teeth, interdental spacing due to microdontia, insufficient overbite, and etc. Full veneer crowns for teeth were selected, followed by a fixed partial denture and implant placement was done using CAD-CAM guide template with bone graft for partially edentulous space. Definitive restorations were duplicated by double scanning provisional restorations and successfully delivered to the patient. These full mouth rehabilitation procedures resulted in satisfactory outcomes for the patient functionally and aesthetically.

Posterior rehabilitation considering mandibular movement with digital facebow transfer and virtual articulator: A case report (디지털 안궁이전과 가상교합기를 이용하여 하악의 운동을 고려한 구치부 수복 증례)

  • Kim, Min-Beom;Kwon, Ho-Beom;Lim, Young-Jun;Kim, Myung-Joo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.60 no.4
    • /
    • pp.431-441
    • /
    • 2022
  • The digital facebow device records the trajectory of the mandibular movement where it is then reflected on the computer-aided design software, leading to an improvement on treatment outcomes of prosthetic restorations. In this clinical case, using a digital technology, an implant placement and prosthetic restoration were done in a patient who has lost maxillary and mandibular molars. Following an intraoral scan, a surgical stent for implant surgery was fabricated based on digital diagnostic wax-up, and implants were installed. After six months of sufficient osseointegration, customized abutments and the first temporary prostheses were delivered. Then two months later, at an abutment level, an intraoral scan and digital facebow transfer device were used to mount the intraoral scan data on a virtual articulator, and record the mandibular movements. Once the second temporary prostheses were fabricated and delivered on a basis of the mandibular movement, the definitive zirconia prostheses were designed and delivered based on a stabilized occlusion that was duplicated via double scan technique.