• Title/Summary/Keyword: 대지전위 상승

Search Result 52, Processing Time 0.032 seconds

Ground Surface Potential Distribution near Ground Rod Associated with Soil Structures (대지구조에 따른 접지봉 주번의 대지표면전위분포)

  • Lee, Bok-Hee;Jung, Hyun-Uk;Baek, Young-Hwan
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.1
    • /
    • pp.142-147
    • /
    • 2007
  • This paper presents the distributions of ground surface potential rises as functions of soil structure and buried depth of ground rod. To propose fundamental data relevant to the reduction of electric shock of human beings due to ground surface rise, the ground surface potential rises near the ground rod were computed and measured. Ground surface potential rises near ground rod strongly depend on the soil structure, and an increase of the buried depth of ground rod results in a decrease of the ground surface potentials. The maximum ground surface potential appeared at the just above point of ground rod. Also, the measured results were in reasonably agreement with the data computered by grounding analysis program.

Fault current flow characteristics of CT secondary circuit connected isolated ground meshes (분리된 접지망에서 CT 2차회로 고장전류 Flow 특성)

  • Lee, Sang-Kil;Kim, Gyeong-Yeol;Choi, Hyung-Joo
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.772-773
    • /
    • 2011
  • 발전단지내 발전소와 변전소 접지망이 서로 연결되지 않고 독립적으로 구성된 경우 설비보호를 위한 보호회로가 큰 대지전위 차로 인해 손상되거나 보호설비가 오동작할 우려가 있다. 본 논문에서는 독립된 접지망간 연결된 보호회로에 대지전위 차로 인해 발생할 수 있는 문제를 분석하였으며 고장전류가 유입된 접지망 전위가 상승하면 CT(Current Transformer)회로가 이중접지 된 곳에서는 보호회로가 오동작할 수 있는 조건이 형성되고, 이중접지가 안되었다 할지라도 대지전위 상승이 회로를 통해 전달되어 회로와 외함간 절연파괴가 일어날 수 있으므로 보호회로 케이블이 발전소와 변전소간 연결된 곳에서는 반드시 접지망을 연결하여야 한다는 것을 확인할 수 있었다.

  • PDF

Analysis of Electric Potential Distribution due to Condition of Grounding Environment (접지환경 조건에 따른 지중함의 전위분포 해석)

  • Kim, Chong-Min;Bang, Sun-Bae;Han, Woon-Ki;Kim, Han-Sang;Shim, Keon-Bo
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.2074-2075
    • /
    • 2007
  • 본 연구에서는 침수된 저압 지중함에서 발생될 수 있는 누전 사고시 지중함내의 접지조건이 주변의 대지전위분포에 미치는 영향을 고찰하였다. 저압 지중함 실증실험장을 설계 구축하였으며 3가지 접지조건의 경우에 대해 대지전위 측정 실험을 실시하였다. case 1과 case2와 같은 실증실험을 통해 저압 지중함에 설치되어 있는 접지선은 저압 지중함에서 대지전위 분포에 거의 영향이 없음을 확인하였으며, case 3과 같은 실증실험을 통해 저압 지중함 철재틀에 접지단자를 본딩 할 경우 저압 지중함 주변의 대지전위 상승이 거의 발생되지 않음을 확인하였다. 따라서 저압 지중함 철재틀에 접지단자를 본딩 할 경우 혹시 발생될 수 있는 지중함의 누전에 의한 감전사고를 매우 효과적으로 방지할 수 있을 것이다.

  • PDF

Design of Grounding System for Rock Area by Ground Resistivity measurement (암반지형에서의 대지저항률 측정을 통한 접지설계)

  • Lee, Jeong-Hun;An, Ho Sung;Maeng, JongHo;Mun, Seong Duk;Ahn, Heesung
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.394-395
    • /
    • 2015
  • 접지시스템은 전력계통에서 사고가 발생하거나 접지가 시공된 시설물에 낙뢰가 침입하는 경우와 같이 고장 전류나 써지가 발생하였을 때 대지로 신속하게 방전시켜 전력기기의 파손 및 고장을 방지하고 대지 전위 상승을 억제하여 인체에 대한 안전성을 확보를 해야한다. 본 논문에서는 대지저항률이 높은 암반지형에서 접지시스템을 설계하기 위해서 대지저항률을 측정하여 토양모델을 모의하였으며, 접지망 설계를 통해 대지 전위 상승을 모의하여 인체 안전 측면을 검토하고자 한다.

  • PDF

Study on the Safety of the Grounding Rods in the Distribution System (IEEE Std 80에 따른 배전용 접지동봉의 안전성 검토)

  • Kang, Moon-Ho;Lee, Heung-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.470-471
    • /
    • 2006
  • 다중 접지 배전계통에서 발생하는 이상전압으로부터 전력설비의 안정적인 운영과 인체안전을 위해 주로 봉상 접지전극을 이용하여 대지방전경로를 구성하고 있다. 그리고 접지종류별로 접지 저항값을 규정하고 이를 시공에 적용하고 있다. 지락고장이 발생하면 접지전극으로 유입되는 고장전류에 비례하여 대지전위가 상승하기 때문에 이에 대한 인체 안전성측정 및 검토가 필요하다. 따라서 본 논문에서는 IEEE Std 80에서 제시하는 안전성 기준에 기초하여 다중 접지 배전계통에서 접지전극으로 널리 사용되는 봉상 접지전극을 대상으로 상용주파전류를 인가하여 대지전위상승에 따른 접촉전압을 측정하였으며, CDEGS 프로그램을 이용하여 보폭전압을 모의하였다. 또한 이 값을 IEEE Std 80에서 제시하는 최대 허용 보폭전압과 접촉전압과 비교하여 인체 안전성을 검토하였다.

  • PDF

765kV 심형기초 철탑의 정상 접지저항

  • 한국전력기술인협회
    • Electric Engineers Magazine
    • /
    • v.195 no.11
    • /
    • pp.30-34
    • /
    • 1998
  • 가공송전선의 접지는 주로 내뢰설계에 그 목적이 있지만 전력계통의 안정도, 전력계통의 고장검출과 철탑주변의 접촉전압 및 보폭전압에도 영향을 미치고 있는 것이 사실이다. 특히 전력계통에서 지락사고가 발생할 경우 지락전류가 송전철탑에 시설되어 있는 가공지선과 대지로 분류하는 정도에 따라 지락지점에서의 대지전위 상승이 크게 좌우된다.

  • PDF

DESIGN OF OPTIMUM GROUNDING BY THE RESISTIVITY ANALYSIS OF MULTI-LAYERED SUBSURFACE (다층 대지비저항 해석에 의한 최적 접지설계)

  • HyoungSooKim
    • Journal of the Korean Geophysical Society
    • /
    • v.6 no.3
    • /
    • pp.179-188
    • /
    • 2003
  • The object of grounding of electrical facility is to protect human and machine damage from the power supply interruption high voltage by use of the accident current dissipating into the ground. Generally, it is not easy to make suitable ground design for inhomogeneous subsurface geology and the variability of accident current in magnitude and duration time. To make efficient ground, ground potential rise must be controlled in the way of overall lowering and evenness. This study shows the case of optimized ground design by use of subsurface resistivity structure from electrical soundings.

  • PDF

수변전설비의 최적관리와 트러블 대책⑦

  • 한국전력기술인협회
    • Electric Engineers Magazine
    • /
    • v.242 no.10
    • /
    • pp.11-14
    • /
    • 2002
  • 철탑, 건물 또는 피뢰침에 낙뢰가 들어오게 되면 그 접지극 부근의 대지전위가 상승하고 다른 접지극에서 기기로 뇌 써지가 역류하기도 하고 피뢰기와 보호소자를 역섬락시켜 배전선측, 통신선측으로 뇌 써지가 흐른다. 한편 철탑이 건물의 옥상에 있는 경우는 피뢰침이 건물의 철골, 철근과 연결되어 있으므로 뇌써지는 건물에도 흐르고 그것도 접속되어 있는 기기의 지지물을 통하여 다른 접지계통에 유입된다.

  • PDF

A Study on Development of Lightning and Surge Protection System for Electrical Fire Prevention (전기화재 예방을 위한 낙뢰 및 써지 보호시스템 개발에 관한 연구)

  • Kwak, Dong-Kurl
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.13 no.3 s.40
    • /
    • pp.27-32
    • /
    • 2006
  • The occurrence frequency of lightning and surge from the weather accident is increasing recently, which the damage scale have been enlarged every year. A protection system development to solve these problems have been risen to a multinational concern field. In this paper, a novel protection system is proposed to restrain lightning and various surges which happen in electricity and communication equipment. The proposed protection system is designed to the structure to restrain the rise of the earth potential which is become to the problem of conventional protection system. The secondary damage as a result does not happen. The practicality of the developed surge protection system is proved through various accident occurrence simulator.

  • PDF

Evaluations on the Potential Interferences between Ground Rods (봉상 접지전극 상호간의 전위간섭에 대한 평가)

  • Lee, Bok-Hee;Lee, Su-Bong;Lee, Tae-Hyung;Jung, Hyun-Uk;Kil, Hyung-Jun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.5
    • /
    • pp.92-98
    • /
    • 2006
  • This paper deals with the potential interferences between ground rods. To propose a method for reducing the potential interference caused by grounding electrodes, the theoretical analysis and the reduced scale model tests, which we related to the measurement and computation of ground potential rise and potential interference caused by actual-sized grounding electrodes where current is injected, were carried out. The ground potential rise and potential interference coefficients were measured by using the hemispherical water tank grounding simulator and calculated by CDEGS software as a function of the distance between grounding electrodes. The ground potential rises and potential interference coefficients strongly depend on the distance between grounding electrodes, and the measured results were compared with the computer calculated data and were known in good agreement.