• Title/Summary/Keyword: 대조도 대 잡음비

Search Result 128, Processing Time 0.026 seconds

Optimization of Image Quality according to Sensitivity and Tube Voltage in Chest Digital Tomosynthesis (디지털 흉부단층합성검사에서 감도와 관전압 변화에 따른 영상 최적화)

  • Kim, Sang-Hyun
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.4
    • /
    • pp.541-547
    • /
    • 2018
  • To evaluate the effect of dose and image quality for Chest Digital Tomosynthesis(CDT) using sensitivity and tube voltage(kV). CDT images of the phantom were acquired varying sensitivity 200, 320, 400 according to set tube voltage of 125 kV and 135 kV. The dose and Dose Area Product(DAP) according to change of sensitivity and kV were evaluated and Image quality was evaluated by PSNR, CNR, SNR using Image J. Dose were lowered 14~23% less than sensitivity 200, 125 kV and DAP were lowered 13~26% less than sensitivity 200, 125 kV. PSNR were over 27 dB, which were significant value and CNR, SNR were better as sensitivity value was lower. But there were different statistical significant to each item. CNR and SNR were not statistically significant at sensitivity 320, 135 kV(P>0.05). CDT can improve image quality with lower radiation dose using better than quality and correction power at digital radiography system.

Evaluation of Usefulness of IDEAL(Iterative decomposition of water and fat with echo asymmetry and least squares estimation) Technique in 3.0T Breast MRI (3.0T 자기공명영상을 이용한 유방 검사시 IDEAL기법의 유용성 평가)

  • Cho, Jae-Hwan
    • Journal of Digital Contents Society
    • /
    • v.11 no.2
    • /
    • pp.217-224
    • /
    • 2010
  • The purpose of this study was to examine the usefulness of IDEAL technique in breast MRI by performing a quantitative comparative analysis in patients diagnosed with DCIS. On a 3.0T MR scanner, fat-suppressed T2-weighted images and T1-weighted images before and after contrast enhancement were obtained from 20 patients histologically diagnosed with ductal carcinoma in situ (DCIS). The findings from the quantitative image analysis are the following: 1) On T2-weighted images, SNR were not significantly different in the lesion area itself between the CHESS and IDEAL groups, while the IDEAL group showed higher SNR at the ductal area and fat area than the CHESS group. In addition, the CNR were higher for the IDEAL group in those regions. 2) On T1-weighted images before enhancement, SNR were not significantly different in the lesion area itself between the CHESS and IDEAL groups, while the IDEAL group showed higher SNR at the ductal area and fat area than the CHESS group. In addition, the CNR were higher for the IDEAL group in those regions. 3) On T1-weighted images after enhancement, SNR were not significantly different in the lesion area itself between the CHESS and IDEAL groups, while the IDEAL group showed higher SNR at the ductal area and fat area than the CHESS group.

The Effectiveness of 3D FIESTA (Three Dimensional Fast Imaging Employing Steady-state Acquisition) MRI in Sudden Hearing Loss Patients (돌발성 난청 환자에서 3D FIESTA (three dimensional fast imaging employing steady-state acquisition) MRI의 유용성)

  • Cho, Jae-Hwan;Kim, Hyun-Ju;Park, Cheol-Soo
    • Journal of Digital Contents Society
    • /
    • v.11 no.4
    • /
    • pp.425-431
    • /
    • 2010
  • This study explored the effects and the effectiveness of the new method of 3D FIESTA by making quantitative comparison with the conventional 3D FSE method which is frequently employed on patients with sudden hearing loss in clinical settings. For this study, 3D FSE images acquired with 3.0T MR scanner and T2-weighted axial plane 3D FIESTA images were respectively taken from 40 patients diagnosed with Sensorineural Hearing Loss (SSHL). When obtaining those images, sagittal reconstructions oriented perpendicular to the nerve were performed in order to get sagittal images of both right and left internal auditory canal. The findings showed that both SNR and CNR were higher among the group to whom the 3D FIESTA method was applied than the group to whom the conventional 3D FSE method was applied.

Evaluation of New Material Mammopad (맘모패드의 새로운 재질에 관한 평가)

  • Moon, Young-Ju;Kim, Sang-Hyun
    • Journal of radiological science and technology
    • /
    • v.42 no.4
    • /
    • pp.265-270
    • /
    • 2019
  • Mammography is the most useful test for the early diagnosis of breast cancer. The MammoPad can be used for the purpose of reducing the pain felt by the patient due to the pressure of the breast. MammoPad cushion the pressure between the breasts and the equipment and reduce the patient's discomfort. A new material pad was fabricated to solve the problem of the H-pad which is currently in circulation. Quantitative evaluation of SNR and CNR and qualitative evaluation of imitation lesion using ACR Phantom were performed. In the quantitative evaluation, SNR and CNR of Non pad and Filter pad were not statistically significant.(p>0.05) In the qualitative evaluation, Fiber and Imitation lesion of H-pad and Filter pad were statistically significant(p<0.05), and all values of Calcification and Mass were not statistically significant. (p>0.05) In addition, Fiber, calcification, mass, and imitation lesion were not statistically significant in both Non pad and Filter pad.(p>0.05) Through this study, it was confirmed that the newly created Filter pad minimizes image quality degradation and can replace existing products.

Effect of Antibacterial Film Containing Silver Ions on MRI (은(Ag)이온이 함유된 항균필름이 MRI에 미치는 영향)

  • Shin, Byeong Geun;Kim, Seong Hu;Ahn, Seong Min
    • Journal of radiological science and technology
    • /
    • v.44 no.3
    • /
    • pp.219-224
    • /
    • 2021
  • The purpose of these experiments is often to scan infected patients with MRI. Therefore, it is to investigate whether the antibacterial film containing silver ions, which is a non-magnetic substance, affects magnetic resonance imaging. In this experiment, the ACR phantom was used, not the patient. The ACR phantom was wrapped in an antibacterial film and the SNR, CNR, sagittal localization image, and geometrical accuracy were compared before and after. The experiment was performed 10 times and the averaged values were compared. There were no significant differences in the results of all experiments. The FDA recommends removing metal and antibacterial film masks during MRI scans. The reason is that there was one case of injury with facial burns. When I touched the antibacterial film to check the fever during the 2 hour experiment, I did not feel any particular fever. In light of the experimental results, it would be helpful to use an antibacterial film when testing an infected patient. The reason is that there isn't a difference before and after the experiment of SNR, CNR, and sagittal localization images.

Radiation Dose and Image Quality of Low-dose Protocol in Chest CT: Comparison of Standard-dose Protocol (흉부 CT촬영에서 저선량 프로토콜의 선량과 화질: 표준선량 프로토콜과 비교)

  • Lee, Won-Jeong;Ahn, Bong-Seon;Park, Young-Sun
    • Journal of Radiation Protection and Research
    • /
    • v.37 no.2
    • /
    • pp.84-89
    • /
    • 2012
  • The purpose of this study was to compare radiation dose and image quality between low-dose (LDP) and standard-dose protocol (SDP). LDP (120 kVp, 30 mAs, 2-mm thickness) and SDP (120 kVp, 180 mAs, 1.2-mm thickness) images obtained from 61 subjects were retrospectively evaluated at level of carina bifurcation, using multi-detector CT (Brilliance 16, Philips Medical Systems). Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated at ascending aorta and infraspinatus muscle, from CT number and back-ground noise. Radiation dose from two protocols measured at 5-point using acrylic-phantom, and CT number and noise measured at 4-point using water-phantom. All statistical analysis were performed using SPSS 19.0 program. LDP images showed significantly more noise and a significantly lower SNR and CNR than did SDP images at ascending aorta and infraspinatus muscle. Noise, SNR and CNR were significantly correlated with body mass index (p<0.001). Radiation dose, SNR and CNR from phantom were significant differences between two protocols. LDP showed a significant reduction of radiation dose with a significant change in SNR and CNR compared with SDP. Therefore, exposure dose on LDP in clinical applications needs resetting highly more considering image quality.

Evaluation of Image Quality according to the Use of Attachable X-ray Table Equipped with Heating Device (가열장치를 구비한 부착형 X선 촬영대의 사용에 따른 화질 평가)

  • Song, Jongnam;Kim, Eungkon
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.4
    • /
    • pp.219-225
    • /
    • 2015
  • This study aims to evaluates the image quality of CR and DR that are scanned with the use of the attachable carbon heater X-ray scanner table equipped with heating device by measuring SNR and CNR before and after the attachment of the said table. In the aluminum staircase testing, CR increased SNR and CNR when attached with the table, while DR decreased SNR and CNR. In the human-body model phantom testing, CR increased SNR and CNR only in the low-energy low-dose radiation and the high-energy high-dose radiation, but decreased SNR and CNR under all other conditions. In conclusion, the use of such table can make the patient feel comfortable by removing his or her anxiety, thus helping the testing, but in the actual clinical application thereof, if the thickness and material of the bottom film and the protective film, including the carbon heater, are not considered, it affects the picture quality, thereby requiring continuous research on the use of such table.

The Value of Three-Dimensional Reconstructions of MRI Imaging using Maximum Intensity Projection Technique (유방 MRI의 최대강도투사 기법에 의한 3차원 재구성 영상의 유용성)

  • Cho, Jae-Hwan;Lee, Hae-Kag;Hong, In-Sik;Kim, Hyun-Joo;Jang, Hyun-Cheol;Park, Cheol-Soo;Park, Tae-Nam
    • Journal of Digital Contents Society
    • /
    • v.12 no.2
    • /
    • pp.157-164
    • /
    • 2011
  • The purpose of this study was to examine the usefulness of 3D reconstruction images in breast MRI by performing a quantitative comparative analysis in patients diagnosed with DCIS. On a 3.0T MR scanner, subtraction images and 3D reconstruction images were obtained from 20 patients histologically diagnosed with ductal carcinoma in situ (DCIS). The findings from the quantitative image analysis are the following: The 3D reconstruction images showed higher SNR at the lesion area, ductal area, and fat area that of the subtraction image. In addition, the CNR were not significantly different in the lesion area itself between the subtraction images and 3D reconstruction images.

Quantitative Assessment using SNR and CNR in Cerebrovascular Diseases : Focusing on FRE-MRA, CTA Imaging Method (뇌혈관 질환에서 신호대 잡음비와 대조도대 잡음비를 이용한 정량적평가 : FRE-MRA, CTA 영상기법중심으로)

  • Goo, Eun-Hoe
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.6
    • /
    • pp.493-500
    • /
    • 2017
  • In this study, data analysis has been conducted by INFINITT program to analyze the effect of signal to noise ratio(SNR) and contrast to noise ratio(CNR) of flow related enhancement(FRE) and computed tomography Angiography(CTA) on cerebrovascular diseases for qualitative evaluations. Based on the cerebrovascular image results achieved from 63 patients (January to April, 2017, at C University Hospital), we have selected 19 patients that performed both FRE-MRA and CTA. From the 19 patients, 2 were excluded due to artifacts from movements in the cerebrovascular image results. For the analysis conditions, we have set the 5 part (anterior cerebral artery, right and left Middle cerebral artery, right and left Posterior cerebral artery) as the interest area to evaluate the SNR and CNR, and the results were validated through Independence t Test. As a result, by averaging the SNR, and CNR values, the corresponding FRE-MRA achieved were: anterior cerebral artery ($1500.73{\pm}12.23/970.43{\pm}14.55$), right middle cerebral artery ($1470.16{\pm}11.46/919.44{\pm}13.29$), left middle cerebral artery ($1457.48{\pm}17.11/903.96{\pm}14.53$), right posterior cerebral artery ($1385.83{\pm}16.52/852.11{\pm}14.58$), left posterior cerebral artery ($1318.52{\pm}13.49/756.21{\pm}10.88$). by averaging the SNR, and CNR values, the corresponding CTA achieved were: anterior cerebral artery ($159.95{\pm}12.23/123.36{\pm}11.78$), right middle cerebral artery ($236.66{\pm}17.52/202.37{\pm}15.20$), left middle cerebral artery ($224.85{\pm}13.45/193.14{\pm}11.88$), right posterior cerebral artery ($183.65{\pm}13.47/151.44{\pm}11.48$), left posterior cerebral artery ($177.7{\pm}16.72/144.71{\pm}11.43$) (p < 0.05). In conclusion, MRA had high SNR and CNR value regardless of the cerebral infarction or cerebral hemorrhage observed in the 5 part of the brain. Although FRE-MRA consumed longer time, it proved to have less side effect of contrast media when compared to the CTA.

Evaluation of Tendency for Characteristics of MRI Brain T2 Weighted Images according to Changing NEX: MRiLab Simulation Study (자기공명영상장치의 뇌 T2 강조 영상에서 여기횟수 변화에 따른 영상 특성의 경향성 평가: MRiLab Simulation 연구)

  • Kim, Nam Young;Kim, Ju Hui;Lim, Jun;Kang, Seong-Hyeon;Lee, Youngjin
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.1
    • /
    • pp.9-14
    • /
    • 2021
  • Recently, magnetic resonance imaging (MRI), which can acquire images with good contrast without exposure to radiation, has been widely used for diagnosis. However, noise that reduces the accuracy of diagnosis is essentially generated when acquiring the MR images, and by adjusting the parameters, the noise problem can be solved to obtain an image with excellent characteristics. Among the parameters, the number of excitation (NEX) can acquire images with excellent characteristics without additional degradation of image characteristics. In contrast, appropriate NEX setting is required since the scan time increases and motion artifacts may occur. Therefore, in this study, after fixing all MRI parameters through the MRiLab simulation program, we tried to evaluate the tendency of image characteristics according to changing NEX through quantitative evaluation of brain T2 weighted images acquired by adjusting only NEX. To evaluate the noise level and similarity of the acquired image, signal to noise ratio (SNR), contrast to noise ratio (CNR), root mean square error (RMSE) and peak signal to noise ratio (PSNR) were calculated. As a result, both noise level and similarity evaluation factors showed improved values as NEX increased, while the increasing width gradually decreased. In conclusion, we demonstrated that an appropriate NEX setting is important because an excessively large NEX does not affect image characteristics improvement and cause motion artifacts due to a long scan.