• Title/Summary/Keyword: 대동맥판막 성형술

Search Result 73, Processing Time 0.02 seconds

Small Aortic Annulus in Aortic Valve Replacement; Comparison between Aortic Annular Enlargement Group and Patient-prosthesis Mismatch Group (협소한 대동맥판륜 환자에서의 대동맥판막 치환술; 대동맥판륜 확장술군과 환자-인공판막 부조화군의 비교)

  • Kim, Jae-Hyun;Oh, Sam-Sae;Yie, Kil-Soo;Shin, Sung-Ho;Baek, Man-Jong;Na, Chan-Young
    • Journal of Chest Surgery
    • /
    • v.40 no.3 s.272
    • /
    • pp.200-208
    • /
    • 2007
  • Background: The effect of patient-prosthesis mismatch (PPM) on the clinical outcome following aortic valve replacement (AVR) remains controversial. This study compared the surgical outcomes of AVR between patients with a patient-prosthesis mismatch and those having undergone an aortic annular enlargement. Material and Method: Six hundred and twenty seven adult patients, who underwent AVR with stented bioprosthetic or mechanical valves, between January 1996 and February 2006, were evaluated. PPM was defined as an indexed effective orifice area (iEOA) ${\leq}0.85cm^2/m^2$, and Severe if the iEOA${\leq}0.65cm^2/m^2$ PPM was present in 103 (16.4%, PPM group) patients, and severe in 11 (1.8%, SPPM group). During the period of the study, 21 patients underwent an AVR with annular enlargement (AE group). Result: The mean iEOA of the AE group was larger than that of the PPM group ($0.95\;vs.\;0.76cm^2/m^2,\;p=0.00$). The AE group had longer CPB, ACC and operation times than the PPM group, and showed a tendency toward higher operative mortality (14.3% vs. 2.9%, p=0.06). The SPPM group had higher AV pressure gradients (peak/mean) than the AE group (72/45 mmHg vs. 38/25 mmHg, p=0.02/0.06) and suffered more AV related events (AV reoperation or severe aortic stenosis)(45.5% vs. 9.5%, p=0.03). LV masses were not regressed in the patients who experienced an AV related event. Conclusion: During AVR in patients with a small aortic annulus, annular enlargement should be carefully applied taking into account the high risk of operative mortality due to annular enlargement and co-morbidities of patients. Aortic annular enlargement; however, should be considered as an alternative method in patients expected to have a severe PPM after an AVR.

Reduction Aortoplasty with Suture Plication Technique for Dilatation of the Ascending Aorta associated with Aortic Valve Disease (대동맥판막 질환과 동반된 상행대동맥 확장에 대한 봉합봉축법에 의한 대동맥 축소성형술)

  • Na Chan-Young;Oh Sam-Sae;Lee Chang-Ha;Whang Seong Wook;Lee Cheol;Lim Hong Gook;Kim Jae Hyun;Seo Hong Ju;Kim Gun Gyk;Baek Man-Jong
    • Journal of Chest Surgery
    • /
    • v.38 no.3 s.248
    • /
    • pp.221-228
    • /
    • 2005
  • Reduction aortoplasty has been advocated for dilatation of the ascending aorta associated with aortic valve disease in older, high-risk patients. We report our results with modification of reduction aortoplasty and aortic valve replacement. Material and Method: Between July 2001 and December 2002, 14 consecutive patients who underwent modification of reduction aortoplasty, suture plication technique without excision of the dilated aortic wall, were reviewed. The mean age was 63.7$\pm$6.7 (50 to 75) years. Ten patients had congenital bicuspid aortic valve, Twelve patients had severe aortic valve stenosis and 6 had regurgitation of grade III$\~$IV. The diameter of the ascending aorta was measured before and immediately after surgery and 6 and 12 months postoperatively using echocardiography or computed tomography. Follow-up was complete in an average of 14.7$\~$5.4 (7 to 24) months. Result: There were no early postoperative deaths and no bleeding complications. Reduction aortoplasty with suture plication technique decreased the diameter of ascending aorta from 49.4$\pm$3.5 mm preoperatively to 33.2$\pm$3.4 mm postoperatively (p <0.001). During follow-up, there were no late deaths and no aneurysm recurrence on the ascending aorta. Conclusion: Suture plication technique of reduction aortoplasty without excision of the dilated aortic wall offers good early and short-term results in older, high-risk patients with dilatation of the ascending aorta associated with aortic valve disease. Surgical long-term results of our technique should be evaluated in further studies.

Fibrocalcific Embolism of Right Coronary Artery Combined with Aortic Valvular Stenosis (대동맥판협착증에 동반된 우관상동맥의 석회성 색전증)

  • 장성욱;박정옥;김영권;이명용;류재욱;박성식;서필원;김삼현
    • Journal of Chest Surgery
    • /
    • v.36 no.11
    • /
    • pp.858-861
    • /
    • 2003
  • The main cause of ischemic heart disease combined with aortic valve disease is the systemic atherosclerotic process. Coronary artery embolism by a particle from the calcified aortic valvular tissue is very rare. A 73-year-old female patient was admitted due to chest tightness of recent onset. Two dimensional echocardiogram showed severe calcific aortic valve stenosis. Preoperative coronary angiogram exhibited a stenotic lesion at the distal right coronary artery, which seemed to be embolic in origin. The coronary embolus was removed through the coronary arteriotomy and then the arteriotomy site was repaired by onlay patch angioplasty technique. Aortic valve was replaced by a bioprosthetic valve. The embolus was reported as a fibrocalcified particle of diseased valve.

Surgical Treatment for Multivalvular Heart Disease (중복 심장판막 질환의 외과적 치료)

  • Kim, Jin; Jo, Jung-Ku;Kim, Kong-Soo
    • Journal of Chest Surgery
    • /
    • v.29 no.8
    • /
    • pp.875-882
    • /
    • 1996
  • Multlvalvular heart surgery was performed In 78 cases, in the Department of Thoracic & Cardiovascu far Surgery of Chonbuk national University Hospital from november 1983 to March 1994. There Where 31 men and 47 women. whose ranged from 14 to 63 years. The causes of the valvular lesions were 57 rheumatic origin, 18 degenerative, 1 previous endocarditls, 1 prosthetic valve mal-function. There were 25 double valve replacement with or wit out tricuspid valve repair, i M VR and aortic valve repair, 18 MVR and tricuspid valve repair, 1 MVR and aortic and tricuspid valve repair, 10 AVR and mi- tral valve repair, 1 AVR and tricuspid valve repair, 8 mitral aortic valve repair, 13 mitral and tricuspid valve repair. They were improved mean New York Heart Association functional cldss, from 2.72% 121 Early deaths were 5 cases(6.4%). The cause of death wet'e low cArdiac output syndrome. veritricular tachycardia, massive bleeding and cerebral thromboembolism. All the survivors belonged to New York Heart Association functional class I or ll at discharge. The patients who had had valve replacement operation were medicated with warfarin to maintain the level of 30∼ 50% of normal prothrombin time. During follow-up(93.6%, mean 49.9 months), 2 late deaths were developed. One was due to intracranial hemorrhage and the other congestive heart failure. The pre-operative New York Heart Association Functional class IV was statistically sig ificant operat- ive risk factors(p< 0.05).

  • PDF

Early Results of Aortic Valve-sparing Procedures in Patients with Annuloaortic Ectasia (대동맥륜대동맥확장(Annuloaortic Ectasia) 환자에서 대동맥판막을 보존하면서 시행된 대동맥근부 및 상행대동맥 치환술의 단기 성적)

  • Sung Kiick;Park Kay-Hyun;Lee Young Tak;Jun Tae-Gook;Yang Ji-Hyuk;Kim Su Wan;Kim Jin Sun;Cho Sung Woo;Kim Si Wook;Choi Jin Ho;Park Pyo Won
    • Journal of Chest Surgery
    • /
    • v.38 no.7 s.252
    • /
    • pp.483-488
    • /
    • 2005
  • Aortic valve-sparing procedures could reduce valve-related morbidity, but may increase operative risks; therefore, these procedures could not be performed routinely. We attempted to find out the early results while focusing on the operative risks associated with these procedures in our hospital. Material and Method: From May 1996 to July 2003, 26 patients underwent these procedures including 15 patients with Marfan syndrome and 1 patient with Behcet disease. There were 17 men and 9 women with mean age of $37.9\pm19.2$ years (range: 6 months-74 years). Ten patients had ascending aortic dissection, 18 patients had more than moderate degree of aortic valve insufficiency (AI). Two types of valve-sparing procedures were performed: valve reimplantation in 14 and root remodeling in 12 patients. Associated procedures were performed as follows: aortic valve plasty in 6, mitral valve plasty in 5, hemi-arch replacement in 4, total arch replacement in 2, coronary artery bypass surgery in 1 and Maze procedure in 1 patient(s). Result: In four patients, valve-sparing procedures were converted to Bentall procedures during operation. Including these patients, there was no operative deaths, 3 patients underwent re-operation due to bleeding, 1 patient had permanent pacemaker. The median duration of ICU stay was 45.5 hours, the median duration of hospital stay was 10.5 days. In 22 patients excluding 4 converted patients, intraoperative transesophageal echocardiogram (TEE) showed less than mild degree of AI in all except one who had not received intra-operative TEE in the beginning and showed moderate degree of AI at discharge. The mean duration of follow-up was $21.2\pm27.4$ months. All patients were alive except one who died during other departmental surgery. In 3 patients, more than moderate degree of AI was recurred, but there were no reoperation. Conclusion: Aortic valve-sparing procedures could be performed relatively safely in selected patients who had annuloaortic ectasia.

Aortic Root Reconstruction for Aortic Insufficiency Developed after Fontal Operation - 1 case - (Fontan 수술후 발생한 대동맥판막역류에 대한 aortic root의 재 건술 - 1례 보고 -)

  • Kyung, Mon-Chol;Whang, Song-Wok;Lee, Chol;Kim, Yung-Jin
    • Journal of Chest Surgery
    • /
    • v.35 no.2
    • /
    • pp.137-140
    • /
    • 2002
  • Aortic regurgitation in the pediatrics who had previous cardiac surgery is increased with their improved longterm survival rate and their complexity of heart disease. So the need of aortic valve surgery in pediatrics is also on the increase. A 10-year old boy was admitted for progressive cyanosis and dyspnea on exertion(DOE). The patient had been underwent lateral tunnel Fontan operation before. Echocardiography and cardiac catheterization study revealed hepatic vein drained to pulmonary atrium via intrahepatic collaterals, moderate atrioventricular regurgitation, and severe aortic regurgitation due to aortic root dilation. We report a case who had aortic root reconstruction, valvuloplasty of the atrioventricular valve, and hepatic vein ligation successfully Cyanosis and DOE was dramatically improved after the operation

Surgical treatment of Supravalvular Aortic Stenosis (판막상부 대동맥협착증의 외과적 요법)

  • 장우익;오삼세;이정렬;김용진;노준량;서경필
    • Journal of Chest Surgery
    • /
    • v.31 no.8
    • /
    • pp.763-769
    • /
    • 1998
  • Background: Supravalvular aortic stenosis is a rare form of congenital cardiac anomaly involving ascending aorta distal to coronary orifice. Materials and methods: We operated 12 cases of supravalvular aortic stenosis between July 1986 and March 1997. Age ranged from 4 to 17(mean 10.2) years and 11 of them were male. Nine patients had clinical features of Williams syndrome. We experienced two types of supravalvular aortic stenosis, including 10 hour glass type and 2 diffuse type. Results: Preoperative transaortic pressure gradient ranged from 40 to 180(mean 92) mmHg by cardiac catheterization. Pulmonary stenosis was associated in 5 and 2 of them required angioplasty. Operative techniques included 6 standard aortoplasty with elliptical patch, 4 extended aortoplasty with inverted Y shaped patch, and 2 modified Brom's repair. There were no operative deaths. Postoperative echocardiographic evaluation was done at a mean interval of 12 months. Grade I or II aortic regurgitation was found in 3 cases. Postoperative cardiac catheterization revealed a mean transaortic pressure gradient of 26 (range 0 to 75) mmHg. A mean pressure drop was 78(range 30 to 114) mmHg. All patients were followed up for a mean of 40(range 1 to 67) months with uneventful clinical course. Conclusions: Our data proved the low mortality and excellent hemodynamic improvement after surgical relief of supravalvular aortic stenosis in children.

  • PDF

Thoracoscopic Aortic Valve Replacement assisted with AESOP (Automated Endoscope System for Optimal Positioning) 3000 (AESOP 3000을 이용한 흉강경적 대동맥 판막 치환술)

  • Shin Hong Ju;Kim Hee Jung;Choo Suk Jung;Song Hyun;Chung Cheol Hyun;Song Meong Gun;Lee Jae Won
    • Journal of Chest Surgery
    • /
    • v.38 no.7 s.252
    • /
    • pp.507-509
    • /
    • 2005
  • Open heart surgery via right thoracotomy can be accomplished in atrial septal defects, and mitral valve diseases. Recently, thoracoscopic atrial septal defect closure, mitral valve repair, Maze operation, and minimal invasive direct coronary artery bypass (MIDCAB) are accomplished with AESOP 3000. However, there is no report of thoracoscopic aortic valve replacement in Korea. We report a successful thoracospic aortic valve replacement assisted with AESOP 3000 in a 31-year-old female patient.

Giant Pseudoaneurysm of Ascending Aorta complicating Recurrent Mediastinitis after Gardiac Surgery (반복된 종격동염 치료후 상행 대동맥에 발생한 거대 가성 대동맥류)

  • Kang, Jun-Gyu;Lee, Chul-Ju;Hong, Jun-Wha;Choi, Ho;So, Dong-Mun;Tak, Seung-Jae
    • Journal of Chest Surgery
    • /
    • v.34 no.3
    • /
    • pp.252-255
    • /
    • 2001
  • 본 30세 여환은 류마치스성 심장판막질환 진단하네 승모판막 및 대동맥판막 치환술 시행후 종격동염 발생하여 지속적 종격동 세척 및 3주간의 항생제 치료후 퇴원하였다. 외래 추적중 다시 감염 및 염증소견 보여 입원하여 혈액배양검사와 흉부전산화 단층촬영시행하였다. 검사상 종격동염의 이후 3주간의 항생제 치료에도 염증 소견이 지속되어 다시 시행한 흉부 전산화단층촬영상 상행대동맥에 거대 가성대동맥류소견보여 재개흉술을 시행하여 초저체온 완전 순환정지 하에 가성대동맥류를 절제한 후, 우심낭편을 이용하여 대동맥 성형술을 시행하였다. 수술후 환자는 순조롭게 회복하였으며 현재 외래에서 추적관리하고 있다.

  • PDF