• Title/Summary/Keyword: 대동맥판막치환술

Search Result 144, Processing Time 0.038 seconds

Risk Factors of Redo-valve Replacement (판막재치환술의 위험인자)

  • 최강주;조광현;김성룡;이상권;전희재;윤영철;이양행;황윤호
    • Journal of Chest Surgery
    • /
    • v.35 no.11
    • /
    • pp.785-791
    • /
    • 2002
  • The results of reoperative valve replacement can be improved if appropriate analysis for the risk of reoperation was achieved. The purpose of our study was to analyze the results of reoperations for failure of bioprosthesis, and to define the risk factors in high-risk populations for reoperative procedures. Material and Method The series of 46 consecutive patients who had undergone first reoperative replacement for failed bioprosthesis between 1993 and 2001 were reviewed retrospectively. Mean age was 42 $\pm$ 12 years, mean body surface area was 1.52 $\pm$0.15 $m^2$. The reoperative procedure comprised of 36 MVR, 8 DVR, and 2 AVR. The first operation comprised of 2 DVR, 1 AVR, and 43 MVR. Factors which were choose to assess a predictor of results in reoperative valve replacement were sex, old age(>60 years), early age at first operation(<30 years), long interval between first and redo operation(.15years), poor NYHA functional class(>3), LV dysfunction(LVEF<45%), long operation time(>8hours), endocarditis, combined procedures, and renal insufficiency, Result : Overall mortality was 4.3%(2 cases). The risk factors that influenced postoperative complications and unexpected postoperative results were lower ejection fraction(p=0.012), older age(p=0.045), endocarditis(p=0.023), long operation time above 8 hours(p=0.027). There was no statistically significant factor influencing hospital mortality. Conclusion : No factor influenced the mortality. Better results could be achieved if reoferation was performed carefully in poor left ventricular function, old aged patient, and with endocarditis. Effort to shorten the operation time would be helpful on postoperative results.

Clinical Experiences of Open Heart Surgery (개심술(開心術) 2,000례의 임상적 고찰)

  • 김하늘루;박경택;곽기오;한일용;소영환;최강주;이양행;조광현
    • Journal of Chest Surgery
    • /
    • v.31 no.12
    • /
    • pp.1183-1194
    • /
    • 1998
  • Background: From Sept. 1985 to Sept. 1997, 2,000 cases of open heart surgery(OHS) were performed in the Department of Thoracic & Cardiovascular Surgery, Pusan Paik Hospital, College of Medicine, Inje University. Material and Method: Among the total of 2,000 cases of OHS, 1532 cases were congenital heart disease(CHD) and 468 cases were acquired heart disease(AHD). The age distribution was 9 days(4.0kg) to 68 years in CHD and 11 to 66 years in AHD. In 1532 cases of CHD, there were 1403 acyanotic cases and 129 cyanotic cases. Result: The CHD cases consisted of 940 ventricular septal defects(61.4%), 324 atrial septal defects(21.1%), 112 tetralogy of Fallot(7.3%), 46 pulmonary stenosis(3%), 38 endocardial cushion defects(2.5%), 15 valsalva sinus ruptures(1%), 4 transposition of great arteries (0.3%), 4 double outlet right ventricles(0.3%), and etc. Corrective operations were applied for congenital heart disease with a result of 3.1% hospital mortality. Of 468 AHD, 381 cases were valvular heart diseases, 48 ischemic heart diseases, 12 cardiac tumors, 8 annuloaortic ectasias, 16 dissecting aortic aneurysms and etc. In the 381 valvular heart diseases, there were 226 single valve replacements(36 aortic valve replacements(AVR), 188 mitral valve replacements(MVR), and 2 tricuspid valve replacements(TVR), among these were 71 cases of double valve replacements(AVR & MVR), 54 cases of MVR with tricuspid valve annuloplasty(TVA), and 18 cases of AVR, MVR with TVA. The total implanted prosthetic valves were 466. In MVR, 123 St. Jude Medical valves, 90 Carpentier-Edwards valves, 65 CarboMedics valves, 42 Sorin valves and 16 other valves were used. In AVR, 68 St. Jude Medical valves, 36 CarboMedics valves, 14 Carpentier-Edwards valves and 9 other valves were used. Coronary Artery Bypass Surgery(CABG) were performed in 48 cases. The patterns of bypass graft were 14 patients of single vessel graft, 21 patients of two vessels graft, 10 patients of three vessels graft and 3 patients of four vessels graft. Conclusion: The hospital operation mortality rate of congenital acyanotic, cyanotic and acquired heart diseases were 2.0%, 15.5%, and 5.1% respectively. The overall mortality rate was 3.6%(72/2,000).

  • PDF

Regression of Left Ventricular Hypertrophy after AVR in Aortic Valvular Stenosis (대동맥판막협착증 환자에서 판막치환 후 좌심실심근비후의 변화)

  • 이재원;최강주;송명근
    • Journal of Chest Surgery
    • /
    • v.31 no.6
    • /
    • pp.586-590
    • /
    • 1998
  • Background: The regression of the left ventricular hypertrophy after prosthetic valve replacement in patients with aortic valvular stenosis is an important factor to determine the appropriateness of the replaced prosthetic valvular size. Methods: To assess the regression of myocardial hypertrophy, a retrospective analysis of Doppler echocardiographic and electrocardiographic data was undertaken before, soon after(7.5$\pm$2.1 day), and late after(10.7$\pm$1.8 months) surgery in 36 patients(22 males, 14 female, mean age 54$\pm$12.1 years, mean BSA 1.61$\pm$0.15m2) with predominant aortic valvular stenosis. The patients underwent St. Jude Medical aortic valve replacement. By the size of the valves used, the patients were divided into three groups(19, 21 and 23+). Results: The mean body surface area(1.48$\pm$0.13) in the patients with the 19 mm valve was smaller than that in the other groups(1.63$\pm$0.12)(p<0.05). No significant changes of ejection fraction were detected in all groups over time. Left ventricular muscle mass index(gm/m2) was reduced significantly in the 21 and 23+ groups over time(p<0.05), but there were no significant changes in the 19 mm valve group. The electric voltage height on EKG at the period of late after surgery was reduced significantly in all groups(p<0.05). Conclusion: Despite clinical improvement, the LVH was not reduced significantly in 19 mm valve group. Thus we suggest that more attention and additional procedures such as annular enlargement should be taken in patients who will undergo the replacement of 19 mm prosthetic valve.

  • PDF

Modified Bentall Operation and the Double Sewing Ring Technique -2 case reports- (변형식 벤탈수술; 이중봉합링 수술법 - 2예 치험 -)

  • Kim, Tae-Yun;Lee, Jung-Moon;Choi, Jong-Bum;Kim, Min-Ho;Jo, Jung-Ku
    • Journal of Chest Surgery
    • /
    • v.43 no.2
    • /
    • pp.156-160
    • /
    • 2010
  • The Bentall-DeBono operation is the technique of choice for aortic root replacement. When the patients have contraindications for lifelong anticoagulation, the biologic Bentall operation may be a good option. However, complex reoperation may be required when bioprosthetic degeneration occurs. For this reason, a new technique for simple reoperation after the Bentall operation has recently been performed by some surgeons. We performed a similar technique in two patients with aortic root dilation and for whom aortic valve sparing techniques could not be performed because of an unrepairable valve contour, we think this modification seems to be simple and reproducible for reoperation.

Composite valve graft Replacement of the Aortic Root (Composite valve graft를 이용한 대동맥근부 치환술)

  • 백만종;나찬영;김웅한;오삼세;김수철
    • Journal of Chest Surgery
    • /
    • v.35 no.2
    • /
    • pp.102-112
    • /
    • 2002
  • This study was undertaken to analyze the outcome of composite valve graftreplacement(CVGR) for the treatment of aneurysms of the ascending aorta involving the aortic root. Material and Method: Between April 1995 and June 2001, 56 patients had replacement of the ascending aorta and aortic root with a composite graft valve and were reviewed retrospectively. Aortic regurgitation was present in 50 patients(89%), Marfan's syndrome in 18 patients(32%), and bicuspid aortic valve in 7(12.5%). The indications for operation were annuloaortic ectasia(AAE) in 30 patients(53.6%), aortic dissection in 13(23.2%), aneurysms of the ascending aorta involving aortic root in 11(19.6%), and aortitis in 2(3.6%). Cardiogenic shock due to the aortic rupture was present in 2 patients. Nine patients(16%) had previous operations on the ascending aorta or open heart surgery. The operative techniques used for CVGR were the aortic button technique in 51 patients(91%), the modified Cabrol technique in 4, and the classic Bentall technique in 1. The concomitant procedures were aortic arch replacement in 24 patients(43%), coronary artery bypass graft in 8(14.3%), mitral valve repair in 2, redo mitral valve replacement in 1, and the others in 7 The mean time of circulatory arrest, total bypass, and aortic crossclamp were 21$\pm$14 minutes, 186$\pm$68 minutes, and 132$\pm$42 minutes, respectively. Result: Early mortality was 1.8%(1/56). The postoperative complications were left ventricular dysfunction in 16 patients(28.6%), reoperation for bleeding in 7(12.5%), pericardial effusion in 2, and the others in 7. Fifty-three patients out of 55 hospital survivors were followed up for a mean of 23.2 $\pm$ 18.7 months(1-75 months). There were two late deaths(3.8%) including one death due to the traumatic cerebral hemorrhage, and CVGR-related late mortality was 1.9%. The 1- and 6-year actuarial survival was 98.1$\pm$1.9% and 93.2$\pm$5.1%, respectively. Two patients required reoperation for complication of CYGR(3.8%) and two other patients required subsequent operations for dissection of the remaining thoracoabdominal aorta. The 1- and 6-year actuarial freedom from reoperation was 97.8$\pm$2.0% and 65.3$\pm$26.7%, respectively.

Double Valve Replacement via Ministernotomy -A Case Report- (소흉골절개술을 통한 이중판막치환술 -1례 보고-)

  • 백완기;김현태;심상석;조상록;박현희
    • Journal of Chest Surgery
    • /
    • v.31 no.1
    • /
    • pp.52-54
    • /
    • 1998
  • Recently, several versatile approaches via limited incision have been developed for minimally invasive cardiac surgery. As the incision is limited, it is often dfficult to get a satisfactory operative field, especially for the manipulation of two separate lesions such as simultaneous mitral and aortic valve disease with a single limited incision. Here, we describe a case of successful double valve replacement via ministernotomy, which was followed by two cases of minimally invasive aortic valve replacement via transsternal approach. The operative field was unexceptionally satisfactory and the postoperative patient's acceptance was high. The methodology is described with a review of the relevant literatures.

  • PDF

Hemolytic Anemia due to Tiny Prosthetic Paravalvular Leakage (작은 인공판막주위 누출에 의한 용혈성 빈혈)

  • 문광덕;김대영
    • Journal of Chest Surgery
    • /
    • v.29 no.4
    • /
    • pp.444-448
    • /
    • 1996
  • Hemolytic anemia due to tiny prosthetic paravalvular leakage is one of a complication of prosthetic valve replacement. Mild Hemolysls usually occurs after aortic valve replacement with mechanical valve but rarely occurs in mitral valve position especially in case of tissue valve. Cardiac valves fabricated from biologic material are associated with a reduced incidence of hemolytic anemia. Hemolysis was reported in patients with an lonescu-Shiley bovine pericardial xenograft prosthesis in the aortic position but not in the mitral site. A 41-year-old female patient was admitted due to sudden development dark colored urine. About 10 years ago the patient was underwent MVR (Mitral Valve Re lacement) with fTmm lonescu-Shiley valve due to MR (Mitral regurgitation). Echocardiographic examination showed mild degree of mitral regurgitation with valvular thickening. However, there was no definitive evidence of paravalvular leakage. The peripheral blood smear showed nomochromic normocytic anemia, but the hematologic and urinary examination revealed severe hemolytic evidence. Mitral valve replacement with St. Jude Medical valve (27mm) was done and intraoperatively, a tiny paravalvular leakage was found which was regarded as the point of hemolysis. The hemolytic evidence completely disappeared. We are reporting a case of severe hemolytic anemia due to tiny prosthetic paravalvular leakage with a review of the literature.

  • PDF

Composite Graft Aortic Root Replacement with Coronary Button Reimplantation: The Early and Mid-Term Results (Composite graft를 이용한 대동맥근부 치환술: Button 술식의 중단기 결과)

  • 나찬영;백만종;김웅한;오삼세;김수철
    • Journal of Chest Surgery
    • /
    • v.35 no.5
    • /
    • pp.356-364
    • /
    • 2002
  • Background: This study was undertaken to investigate the outcome of composite graft aortic root replacement using coronary button reimplantation technique for the treatment of aneurysms of the ascending aorta involving the aortic root. Material and Method: Between April 1995 and September 2001, 54 patients having aortic root replacement with a composite valve graft using direct coronary button reimplantation were reviewed retrospectively. Left ventricular dysfunction was present in 14 patients(25.9%), aortic regurgitation in 48(89%), and Marfan's syndrome in 17(31.5%). The indications for operation were annuloaortic ectasia in 29 patients(53.7%), aortic dissection in 11(20.4%), aneurysms of the ascending aorta involving aortic root in 12(22.2%), and aortitis in 2(3.7%). Six patients(11.1%) had previous cardiac or ascending aortic operations. Concomitant procedures were arch replacement in 21 patients(38.9%), coronary artery bypass graft in 7(13%), mitral valve repair or replacement in 4(7.4%), and others in 6. The mean time of circulatory arrest, total bypass, and aortic crossclamp were 18 $\pm$ 9 minutes, 177 $\pm$ 42 minutes, and 127 $\pm$ 31 minutes, respectively. Result: There was 1 early death(1.9%). Mean follow-up was 24.6$\pm$ 19.5 months. There were two late deaths(3.8%) including one death due to the traumatic cerebral hemorrhage. The Kaplan-Meier survival rate was 98.0 $\pm$ 2.0% and 93.1 $\pm$ 5.1% at 1 and 6 years, respectively. Two patients required reoperation owing to a false aneurysm at the root anastomosis site and a malfunction of prosthetic aortic valve(3.8%). Staged operation for dissection of the remaining thoracoabdominal aorta was performed in 1 patient. The freedom rate from reoperation was 97.8 $\pm$ 2.0% and 65.3 $\pm$ 26.7% at 1 and 6 years, respectively.

Relation of Neoaortic Root Dilation and Aortic Insufficiency after Arterial Switch Operation (동맥전환술 후의 신생대동맥근부 확장과 대동맥판막폐쇄부전의 관계)

  • 박한기;김도균;홍유선;이종균;최재영;조범구;박영환
    • Journal of Chest Surgery
    • /
    • v.36 no.12
    • /
    • pp.921-927
    • /
    • 2003
  • Arterial switch operation (ASO) has been the most effective surgical option for transposition of the great arteries. But, the inappropriate dilation of the neoaortic root has been reported and its effect on neoaortic valve function and growth of aorta has not been well documented. Material and Method: Forty-eight patients who underwent cardiac catheterization during follow up after arterial switch operation were included in this study. Arterial switch operation was performed at a median age of 18 days (range 1∼211 days). Preoperative cardiac catheterization was performed in 26 patients and postoperative catheterization was performed in all patients at 15.8$\pm$9.6 months after ASO. Postoperative ratios of the diameters of neoaortic annulus, root and aortic anastomosis against the descending aorta were compared to the size of preoperative pulmonary annular, root and sinotubular junction. Preoperative and operative parameters were analyzed for the risk factors of neoaortic insufficiency. Result: There were two clinically significant neoaortic insufficiencies (grade$\geq$II/IV) during follow up, one of which required aortic valve replacement. Another patient required reoperation due to aortic stenosis on the anastomosis site. Post-operatively, neoaortic annulus/DA ratio increased from 1.33$\pm$0.28 to 1.52$\pm$.033 (p=0.01) and neoaortic root/DA ratio increased form 2.02$\pm$0.40 to 2.56$\pm$0.38 (p<0.0001). However, the aortic anastomosis/DA ratio showed no statistically significant difference (p=0.06). There was no statistically significant correlation between the occurrence of neoaortic insufficiency and neoaortic annulus/DA ratio and neoaortic root/DA ratio. Non-neonatal repair (age>30days) (p=0.02), preopeative native pulmonaic valve stenosis (p=0.01), and bisuspid pulmonic valve (p=0.03) were the risk factors for neoaortic insufficiency in univariate risk factor analysis. Conclusion: After ASO, aortic anastomosis site showed normal growth pattern proportional to the descending aorta, but neoaortic valve annulus and root were disproportionally dilated. Significant neoaortic valve insufficiency rarely developed after ASO and neoaortic annulus and root size do not correlate with the presence of postoperative neoarotic insufficiency. ASO after neonatal period, preoperative native pulmonary valve stenosis, and bicuspid native pulmonic valve are risk factors for the development of neoaortic insufficiency.