• Title/Summary/Keyword: 대동맥판막, 수술

Search Result 223, Processing Time 0.021 seconds

A case of congenital ductus arteriosus aneurysm (Congenital ductus arteriosus aneurysm 1례)

  • Wang, Sheng Wen;Kim, Ji Eun;Lee, Young Seok;Lee, Young Ah
    • Clinical and Experimental Pediatrics
    • /
    • v.49 no.12
    • /
    • pp.1363-1366
    • /
    • 2006
  • Aneurysmal dilatation of the ductus arteriosis has been considered a rare but potentially fatal abnormality. The mechanism of ductal aneurysmal formation remains uncertain. Plain chest radiography has proven helpful in the diagnosis of ductus arteriosus aneurysm (DAA), before the application of transthoracic echocardiography. The transthoracic echocardiography is an important tool for the diagnosis and follow-up of DAA. We present a case of congenital ductus arteriosus aneurysm in a newborn, that was an incidental discovery. The diagnosis was made by echocardiography, three-dimensional surface rendering computed tomography (CT), and spontaneous regression after four weeks of follow-up.

Comparision of Inclusion TechnicRue with Open Technique in Patients with Bentall Procedures (Bentall수술에서 inclusion technique 과 open technique의 비교)

  • 김정택;문준호
    • Journal of Chest Surgery
    • /
    • v.30 no.5
    • /
    • pp.506-511
    • /
    • 1997
  • To understand the clinical results of aortic root replacement with either inclusion or open technique, we analysed 53 patients who underwent replacement of the aortic root with composite graft between October,1980, and May, 1995. Annuloaortic ectasia was the most common indication for operation(29 patients), follwed by aortic dissection(22 patients). Among 53 patients, 19(35%) had Marfan syndrome. Three patients died during hospitalization (Mortality: 5.5%). The follow up was possible in 48 patients(Follow-up rate; 94%,mean duration;37 months). The actuarial survival rate at 24 months was 95% in open technique group, and 87% in inclusion technique group. Late complications developed in 10 patients. Dissecting aneurysm in the remaining aorta was noted in 3 patients with inclu ion 1,schnique, and a pseudoaneurysm from coronary artery anastomosis site developed in a patient with inclusion technique. In conclusion, there was no statistical differences in survival for 24 months between inclusion technique and open technique group. But late problems in the remaining aorta or death from unknown cause occurred with moderate frequency : careful follow-up after aortic root replacement thought to be important for long term survival.

  • PDF

Membranous PTEE Monocusp Vlave on the Right Ventricular Outflow Tract (막형 PTEE 단엽판막을 이용한 우심실 유출로 확장수술)

  • 박영환;홍유선;이현성;이종균;조범구
    • Journal of Chest Surgery
    • /
    • v.34 no.4
    • /
    • pp.322-328
    • /
    • 2001
  • 배경: 우심실 유출로 재건술후에는 폐동맥판막부전이 우심실기능에 나쁜 영향을 미친다. 이를 막기 위해 여러 재료로 판막을 제조하여 사용하는데 가피 형성이 적은 막형 ePTEE(expanded polytetrafluoroethylene, Goretex) 단엽판막의 효과를 알아보고자 연구를 시행하였다. 대상 및 방법; 1996년 3월부터 1997년 2월까지 우심실유출로 재건술을 시행받고 수술 1일까지 우심실 압력을 측정할 수 있었던 47명중 막형 Goretex단엽판막을 사용한 환자(비교군) 19명, 사용하지 않은 환자(대조군) 28명에서 단엽판막의 유용성을 조사하였다. 두 군간에는 나이, 체중 그리고 McGoon ratio 등에는 통계학적 차이가 없었다.(p>0.05) 이전의 수술은 대조군에서 19번, 비교군에서 22번을 시행하였다. 우심실 유출로에 대한 수술은 대조군에서 REV수술 2예, 우심실폐동맥 연결수술 8예, 우심실 유출로 재개건술 2예, 우심실 유출로에 대한 수술은 대조군에서 16예였으며, 비교군에서는 REV 수술 5예, Rastelli 씨 수술 6예, 재우심실 유출로 재건술 5예, 그리고 우심실 재건술 3예였다. 결과: 대동맥 차단 시간이나 총심폐순환시간에는 두군간의 차이는 없었다. 또한 수술직후와 수술후 1일째 측정한 우심실 압력 및 좌심방압력의 차이도 두군간에는 차이가 없었으며 수술후 7일째 시행한 심에코도 결과 ejection fraction., 우심실/ 좌심실 압력비 , 그리고 우심실 유출로의 압력차, 강심제 투여일수, 호흡기 사용 기간 등에서도 두군간의 차이는 없었으나 흉관 삽입기간이 비교군에서 의미있게 짧았다. 추적 조사 기간 중 비교군 1예에서 사망을 하였으나. Goretex 단엽판막에 의한 것은 아니였으며 심초음파검사상 우심실 유출로 압력차이나 재수술은 두군간에 차이는 없었으나 폐동맥 폐쇄부전은 비교군에서 의미 있게 낮은 것을 보이고 있다. 결론; 막형 Goretex 단엽판막의 조기성적은 우수하였으며 폐동맥 폐쇄분전의 정도를 적게 하는 효과를 보이나 앞으로 이들이 성장함에 따라 우심실 유출로에 폐쇄를 일으키는지는 계속적인 추적관찰이 요구된다.

  • PDF

Opelative Risk and Results of Reoporation for Heart Valve Prostheses (인공심장판막 재치환술에 대한 수술 위험 인자 및 결과)

  • 김철환;김경훈
    • Journal of Chest Surgery
    • /
    • v.30 no.10
    • /
    • pp.973-978
    • /
    • 1997
  • We reviewed data of 64 patients who underwent reoperation because of prosthetic valve malfunction from January 1991 to December 1995. The indications for reoperation were prosthetic valve failure(primary tissue failure: 53 patients, 82.8%), prosthetic valve thrombosis(6 patients, 9.4%), paravalvular leak(3 patients, 4.7%), prosthetic valve endocarditis(2 patients, 3.6%). Prosthetic valve failure developed most frequently in mitral portion(40 patients, 75%), prosthetic valve thrombosis also in mitral portion(4 patients, 67%), paravalvular leak significantly in aortic portio (3 patients, 100%). Explant period was longest in prosthetic valve failure(mean 107.4 $\pm$ 24.6 months), shortest in prosthetic valve endocarditis with prosthetic valve thrombosis(1 patient, 1 month). Mean explant period, defined as from first valve replacement operation to redo-valve replacement operatopn, was 109.2$\pm$ 10.7 months in mitral portion, 97.8$\pm$ 10.4 months in aortic portion, 109.5$\pm$ 10.4 months in total. Overall hospital mortality was 9.38%. The most common cause of death was the low cardiac output(4 patients), other causes were bleeding(1 patient), CNS injury(1 patient). Preoperative NYHA class IV(P=0.011), emergency operation(P=0.011), prosthetic valve endocarditis(P=0.001) were the independent risk factors, but age, sex, explant period, ACC time, double valve replacement, valve position, second reoperation did not appear to be significant risk factors. Mean follow up period was 28.8 $\pm$ 17.8 months. Actuarial survival at 3 year was 92.0$\pm$6.2%, 2 year event-free survival w s 84.3$\pm$6.1%. We propose that patients undergoing reoperation because of prosthetic valve failure are carfully controlled and selected in regarding to above mentioned risk factors NYHA class IV, emergency operation, prosthetic valve endocarditis in preoperative state. About other risk factors possible, there is necessary of following study.

  • PDF

Acceptability of Low Intensity Anticoagulation Therapy after Mechanical Heart Valve Replacement (기계식 인공 심장판막 치환술 후 낮은 강도 항응혈 관리의 적정성에 관한 연구)

  • Kim, Jong-Woo;Rhie, Sang-Ho;Kim, Young-Chun;Yang, Jun-Ho;Jang, In-Seok;Choi, Jun-Young
    • Journal of Chest Surgery
    • /
    • v.42 no.2
    • /
    • pp.193-200
    • /
    • 2009
  • Background: The long-term administration of oral anticoagulant to the patients with a mechanical heart valve prosthesis is mandatory. However, the appropriate intensity of oral anticoagulant therapy to prevent thromboembolic or hemorrhagic complications is still controversial. We tried to apply low intensity anticoagulant therapy for which the International Normalized Ratios ranged between 1.5 and 2.5, and we analyzed the anticoagulation-related long term outcomes. Material and Method: From January 1992 to December 2002, 144 patients who underwent a single cardiac valve replacement were included in the study, and their ages ranged from 15 to 72 years (mean age: $47.4{\pm}15.1$): there were 49 aortic valve replacements (AVR) and 95 mitral valve replacements (AVR). The patients were followed up monthly or bi-monthly at the outpatient clinic with clinical examinations and measuring the prothrombin time to adjust the International Normalized Ratios (INRs) within the low-intensity target range between 1.5 and 2.5. Result: The follow-up period was 835.3 patient-years (mean: $5.9{\pm}3.5$) and the INRs of 7,706 measurements were available for evaluation. The mean INRs of the aortic and the mitral valve replacement groups were significantly different (p<0.01). All the patients' INRs were within the target range in 61.9% of the measurements. The mean INRs $(2.16{\pm}0.23)$ of the patients with atrial fibrillation, which was found in 30.3% of the patients, were definitely higher than those $(2.03{\pm}0.27)$ measured in the patients with regular rhythm (p<0.01). Thromboembolic episodes occurred in 9 patients with an incidence of 1.08%/patient-year. Major bleeding occurred in 2 patients (MVR) with an incidence of 0.24%/patient-year. The patients who displayed better compliance showed a lower incidence of complications (p=0.000). Conclusion: The anticoagulation therapy with a low-intensity target range after MVR or AVR seems to be effective and feasible, and increasing the patients’ compliance should be done for achieving more effective anticoagulation therapy.

Anatomical Structures of the Aortic Root in Koreans (한국인 대동맥 근부의 해부학적 구조)

  • Kang, Min-Woong;Yu, Jae-Hyeon;Lim, Seung-Pyung;Lee, Young;Kim, Si-Wook;Kim, Su-Il;Chung, In-Hyuk;Na, Myung-Hoon
    • Journal of Chest Surgery
    • /
    • v.40 no.5 s.274
    • /
    • pp.321-328
    • /
    • 2007
  • Background: It is very important to determine the surgical anatomy of the aortic root when performing spreading aortic root preserving heart surgery. This study focuses on the surgical aspect of the aortic root anatomy by performing dissection of Korean cadavers. Material and Method: The subjects were 62 cadavers. We measured the intercommissural distances, heights of the sinuses and the circumference of the sinotubular junction and the aortic annulus. Result: The mean age of death was 61.3 years. The intercommissural distance for the right coronary sinus was $0.73{\pm}2.23mm$, that for the non coronary sinus was $19.34{\pm}2.03mm$, and that for the left coronary sinus was $18.58{\pm}2.15mm$. The height of sinus was $20.59{\pm}2.48mm$ for the right coronary sinus, $18.61{\pm}2.26mm$ for the non coronary sinus and $17.95{\pm}19mm$ for the left coronary sinus. The circumference of the sinotubular junction was $70.73{\pm}5.94mm$ and that of the aortic annulus was $77.94{\pm}5.63mm$. There is no correlation between age and STJ, aortic annulus and the ratio of STJ of aortic annulus respectively (p=0.920, p=0.111, p=0.073). The tilting angle of the sinotubular junction and aortic annulus is from $2.03^{\circ}$ to $7.77^{\circ}$ $(mean=4.90^{\circ})$. Conclusion: The intercommissural distance and the height of the sinus were largest in the right coronary sinus, and the position of the sinotubular junction to the aortic annulus is obliquely tilted levo-posteriorly.

Infective Endocarditis with Patent Ductus Arteriosus at 60 Years Old Patient (동맥관개존증을 가진 60세 환자에서 발생한 심내막염)

  • Ryu, Dae Woong;Lee, Sam Youn
    • Journal of Chest Surgery
    • /
    • v.43 no.1
    • /
    • pp.89-91
    • /
    • 2010
  • Aortic and pulmonary valve endocarditis with patent ductus arteriosus (PDA) is uncommon in adult. A 60-year-old woman was diagnosed with aortic and pulmonary valve endocarditis and PDA. We describe our surgical experience for treating PDA with double valve endocarditis.

Long Term Experience of Mitral Valve Replacement (승모판치환수술의 장기 임상성적)

  • 조용길;류지윤
    • Journal of Chest Surgery
    • /
    • v.29 no.10
    • /
    • pp.1102-1110
    • /
    • 1996
  • Between Oct. 1985 and July 1995, 230 patients underwent mitral valve replacement. There were 77 men and 153 women whose mean age was 35.7 years, range 9 to 62 The concomitant operations were 40 aortic valve replacements(17.4%), 25 tricuspid annuloplasties(10.4%), 8 aortic valve replacements & tricuspid annuloplasties(3.5%), 2 tricuspid valve replacements(0.9%) and others, We used 139 mechanical (76 51. Jude medical, 33 CarboMedics, 30 Sorin) and 91 tissue 386 Carpentier-Edwards, 5 lonescu-Shiley) valves. The early postoperative complications occurred in 28 cases. There were 8 low cardiac output syndrome, 5 pleural effusion, 3 significant arrhythmia, 2 cardiac rupture and others. There were 6 early hospital deaths (2.6%) due to low cardiac output syndrome(2), arrhythmia(2) and ventricul r rupture(2). The cuAmulative notal follow-up period was 764. 4 patient-years with a mean of 4).9 months. The long term follow-up information was available for 212 patients(94.6%). There were 21 cases of valve-related complications. Prosthetic valve failure(10), anti-coagulation related bleeding (5), prosthetic valve endocarditis (4), and thromboembolism (2) occurred at rates of 1.3, 0.7, 0.5, and 0.3%Ipt-yr respectively. Late death occurred In 5 cases (0.7%/pt-yr) associated with prosthetic valve endocarditis (2), heart failure (2) and anti-coagulation related bleeding (1). There was no difference in the rate of freedom from prosthetic valve failure between the mechanical and tissue valve group at 6 years (100%), but there was significant difference at 9 years between the tissue (34.4%) and mechanical valve (100%) group (p=0.032). Actuarial survival rates were 98. 8% in tissue valve. 9).7% in mechanical valve group and 96.6% in total patients at 9 years.

  • PDF

A Successful Replacement of Ascending Aorta and Aortic Valve With a composite Graft (대동맥판막 및 상행대동맥 대치이식술 1례 - Bentall씨 수술 변형술 -)

  • 조경수
    • Journal of Chest Surgery
    • /
    • v.22 no.4
    • /
    • pp.693-697
    • /
    • 1989
  • A forty-eight-year-old female patient with ascending aortic aneurysm with aortic insufficiency underwent a modified Bentall operation. The ascending aorta and the aortic valve were replaced with a composite graft containing a St. Jude valve. The coronary orifices were anastomosed to the tubular Dacron prosthesis by means of a second smaller Gore-Tex tube, and a fistula between the aneurysmal sac and the right atrial appendage was created to drain oozing from the prosthesis. The postoperative course was uneventful and the patient was discharged without complication. She is doing well on the 14 months follow-up.

  • PDF

The Results of using the Cabrol Technique for Aortic Root Replacement (대동맥 근부치환술에 대한 Cabrol 술식의 성적)

  • Kim, Jeong-Won;Lee, Jong-Tae;Cho, Joon-Yong;Kim, Kyu-Tae;Kim, Gun-Jik
    • Journal of Chest Surgery
    • /
    • v.41 no.5
    • /
    • pp.573-579
    • /
    • 2008
  • Background: Composite valve graft replacement is currently the treatment of choice for a wide variety of the lesions of aortic root disease. The purpose of this study was to explore the results of aortic root replacement after using the Cabrol technique over a 13-year period at our institution, and we analyzed the results to help surgeons make better decisions when repairing aortic root disease. Material and Method: Between January 1994 and December 2006, twenty-five patients underwent a Cabrol technique operation at our institution. The mean patient age was $43.7{\pm}14.1$ years old (range: $6{\sim}65$ years) and the male and female ratio was 21:4 (84% : 16%). The patients' follow-up was 100% complete, and the mean follow-up period was $60.7{\pm}50.4$ (range:$1{\sim}162$) months. Annuloaortic ectasia (n=18) was the most frequent cause of aortic disease in this series, followed by aortic dissection (n=7). The mean cardiopulmonary bypass time was $177.2{\pm}44.9$ minutes and the mean aortic cross clamping time was $123.4{\pm}34.1$ minutes. Nine patients were checked with MDCT (Multidetector computed tomography) for evaluating a well functioning secondary graft and the coronary anastomosis site. Result: The early mortality rate was 4% (1 of 25 patients). A significant stenosis, kinking or occlusion of the secondary graft was detected by MDCT in 4 patients. The overall survival rate was 88%. Conclusion: The Cabrol technique demonstrated a significant incidence of long-term complications such as secondary graft stenosis or obstruction. It could be used when the modified Bentall technique is not feasible.