• Title/Summary/Keyword: 대동맥성형술

Search Result 104, Processing Time 0.024 seconds

Surgical treatment of Supravalvular Aortic Stenosis (판막상부 대동맥협착증의 외과적 요법)

  • 장우익;오삼세;이정렬;김용진;노준량;서경필
    • Journal of Chest Surgery
    • /
    • v.31 no.8
    • /
    • pp.763-769
    • /
    • 1998
  • Background: Supravalvular aortic stenosis is a rare form of congenital cardiac anomaly involving ascending aorta distal to coronary orifice. Materials and methods: We operated 12 cases of supravalvular aortic stenosis between July 1986 and March 1997. Age ranged from 4 to 17(mean 10.2) years and 11 of them were male. Nine patients had clinical features of Williams syndrome. We experienced two types of supravalvular aortic stenosis, including 10 hour glass type and 2 diffuse type. Results: Preoperative transaortic pressure gradient ranged from 40 to 180(mean 92) mmHg by cardiac catheterization. Pulmonary stenosis was associated in 5 and 2 of them required angioplasty. Operative techniques included 6 standard aortoplasty with elliptical patch, 4 extended aortoplasty with inverted Y shaped patch, and 2 modified Brom's repair. There were no operative deaths. Postoperative echocardiographic evaluation was done at a mean interval of 12 months. Grade I or II aortic regurgitation was found in 3 cases. Postoperative cardiac catheterization revealed a mean transaortic pressure gradient of 26 (range 0 to 75) mmHg. A mean pressure drop was 78(range 30 to 114) mmHg. All patients were followed up for a mean of 40(range 1 to 67) months with uneventful clinical course. Conclusions: Our data proved the low mortality and excellent hemodynamic improvement after surgical relief of supravalvular aortic stenosis in children.

  • PDF

Reduction Aortoplasty with Suture Plication Technique for Dilatation of the Ascending Aorta associated with Aortic Valve Disease (대동맥판막 질환과 동반된 상행대동맥 확장에 대한 봉합봉축법에 의한 대동맥 축소성형술)

  • Na Chan-Young;Oh Sam-Sae;Lee Chang-Ha;Whang Seong Wook;Lee Cheol;Lim Hong Gook;Kim Jae Hyun;Seo Hong Ju;Kim Gun Gyk;Baek Man-Jong
    • Journal of Chest Surgery
    • /
    • v.38 no.3 s.248
    • /
    • pp.221-228
    • /
    • 2005
  • Reduction aortoplasty has been advocated for dilatation of the ascending aorta associated with aortic valve disease in older, high-risk patients. We report our results with modification of reduction aortoplasty and aortic valve replacement. Material and Method: Between July 2001 and December 2002, 14 consecutive patients who underwent modification of reduction aortoplasty, suture plication technique without excision of the dilated aortic wall, were reviewed. The mean age was 63.7$\pm$6.7 (50 to 75) years. Ten patients had congenital bicuspid aortic valve, Twelve patients had severe aortic valve stenosis and 6 had regurgitation of grade III$\~$IV. The diameter of the ascending aorta was measured before and immediately after surgery and 6 and 12 months postoperatively using echocardiography or computed tomography. Follow-up was complete in an average of 14.7$\~$5.4 (7 to 24) months. Result: There were no early postoperative deaths and no bleeding complications. Reduction aortoplasty with suture plication technique decreased the diameter of ascending aorta from 49.4$\pm$3.5 mm preoperatively to 33.2$\pm$3.4 mm postoperatively (p <0.001). During follow-up, there were no late deaths and no aneurysm recurrence on the ascending aorta. Conclusion: Suture plication technique of reduction aortoplasty without excision of the dilated aortic wall offers good early and short-term results in older, high-risk patients with dilatation of the ascending aorta associated with aortic valve disease. Surgical long-term results of our technique should be evaluated in further studies.

Aortic Valvuloplasty Using Leaflet Extension Technique (판막첨 연장술을 이용한 대동맥판막 성형술의 중기성적 평가)

  • Ahn, Hyuk;Kim, Hyun-jo
    • Journal of Chest Surgery
    • /
    • v.30 no.7
    • /
    • pp.656-662
    • /
    • 1997
  • Aortic valvuloplasty has recently gained attention as an attractive alternative procedure for aortic valvular disease. Between March 1995 to August 1996, 14 patients with pure aortic regurgitation(AR) underwent aortic alvuloplasty using leaflet extension with glutaraldehydepreserved autologous pericardium. There were 11 males and 3 females, and the mean age was 34.8 $\pm$ 15.3 years. Preoperative echocardiography and cardiac catheterization revealed that the degree of AR was mean 3.4$\pm$0.65, and more than moderate degree of mitral regurgitation(MR) were detected in 4 patients. In 12 patients, 3 leaflets were extended and in another 2 patients only one deformed leaflet was extended. Concomitant mitral valvuloplasty (MVP) was performed in 4 patients. The competency of the aortic valve after completion of repair was evaluated by the transesophageal echocardiography in operating theater, and there was no aortic and mitral stenosis or regurgitation. In an early postoperative echocardiography, trivial AR was detected in 3 patients and mild MR in 1 patient. The end-systolic and end-diastolic dimensions of the left ventricle were decreased significantly(p<0.05) as compared with those of preoperative values. T ere was no mortality and no significant postoperative complication encountered. Late complication developed in 2 patients during the follow-up period(mean 7.9$\pm$ 5.9 months). One patient underwent AVR on postoperative 7th month due to endocarditis, and the another patient with Behcet's disease underwent Ross operation at postoperative 4th month. In conclusion, AVP of leaflet extension technique offers an excellent early clinical result and represents a good alterna!ivy surgical treatment for the pure AR especially in young age group, although long-term follow-up is necessary to determine the durability of glutaraldehyde-preserved autologous pericardium as a valve leaflet.

  • PDF

Small Aortic Annulus in Aortic Valve Replacement; Comparison between Aortic Annular Enlargement Group and Patient-prosthesis Mismatch Group (협소한 대동맥판륜 환자에서의 대동맥판막 치환술; 대동맥판륜 확장술군과 환자-인공판막 부조화군의 비교)

  • Kim, Jae-Hyun;Oh, Sam-Sae;Yie, Kil-Soo;Shin, Sung-Ho;Baek, Man-Jong;Na, Chan-Young
    • Journal of Chest Surgery
    • /
    • v.40 no.3 s.272
    • /
    • pp.200-208
    • /
    • 2007
  • Background: The effect of patient-prosthesis mismatch (PPM) on the clinical outcome following aortic valve replacement (AVR) remains controversial. This study compared the surgical outcomes of AVR between patients with a patient-prosthesis mismatch and those having undergone an aortic annular enlargement. Material and Method: Six hundred and twenty seven adult patients, who underwent AVR with stented bioprosthetic or mechanical valves, between January 1996 and February 2006, were evaluated. PPM was defined as an indexed effective orifice area (iEOA) ${\leq}0.85cm^2/m^2$, and Severe if the iEOA${\leq}0.65cm^2/m^2$ PPM was present in 103 (16.4%, PPM group) patients, and severe in 11 (1.8%, SPPM group). During the period of the study, 21 patients underwent an AVR with annular enlargement (AE group). Result: The mean iEOA of the AE group was larger than that of the PPM group ($0.95\;vs.\;0.76cm^2/m^2,\;p=0.00$). The AE group had longer CPB, ACC and operation times than the PPM group, and showed a tendency toward higher operative mortality (14.3% vs. 2.9%, p=0.06). The SPPM group had higher AV pressure gradients (peak/mean) than the AE group (72/45 mmHg vs. 38/25 mmHg, p=0.02/0.06) and suffered more AV related events (AV reoperation or severe aortic stenosis)(45.5% vs. 9.5%, p=0.03). LV masses were not regressed in the patients who experienced an AV related event. Conclusion: During AVR in patients with a small aortic annulus, annular enlargement should be carefully applied taking into account the high risk of operative mortality due to annular enlargement and co-morbidities of patients. Aortic annular enlargement; however, should be considered as an alternative method in patients expected to have a severe PPM after an AVR.

Surgical Treatment for Multivalvular Heart Disease (중복 심장판막 질환의 외과적 치료)

  • Kim, Jin; Jo, Jung-Ku;Kim, Kong-Soo
    • Journal of Chest Surgery
    • /
    • v.29 no.8
    • /
    • pp.875-882
    • /
    • 1996
  • Multlvalvular heart surgery was performed In 78 cases, in the Department of Thoracic & Cardiovascu far Surgery of Chonbuk national University Hospital from november 1983 to March 1994. There Where 31 men and 47 women. whose ranged from 14 to 63 years. The causes of the valvular lesions were 57 rheumatic origin, 18 degenerative, 1 previous endocarditls, 1 prosthetic valve mal-function. There were 25 double valve replacement with or wit out tricuspid valve repair, i M VR and aortic valve repair, 18 MVR and tricuspid valve repair, 1 MVR and aortic and tricuspid valve repair, 10 AVR and mi- tral valve repair, 1 AVR and tricuspid valve repair, 8 mitral aortic valve repair, 13 mitral and tricuspid valve repair. They were improved mean New York Heart Association functional cldss, from 2.72% 121 Early deaths were 5 cases(6.4%). The cause of death wet'e low cArdiac output syndrome. veritricular tachycardia, massive bleeding and cerebral thromboembolism. All the survivors belonged to New York Heart Association functional class I or ll at discharge. The patients who had had valve replacement operation were medicated with warfarin to maintain the level of 30∼ 50% of normal prothrombin time. During follow-up(93.6%, mean 49.9 months), 2 late deaths were developed. One was due to intracranial hemorrhage and the other congestive heart failure. The pre-operative New York Heart Association Functional class IV was statistically sig ificant operat- ive risk factors(p< 0.05).

  • PDF

Composite valve graft Replacement of the Aortic Root (Composite valve graft를 이용한 대동맥근부 치환술)

  • 백만종;나찬영;김웅한;오삼세;김수철
    • Journal of Chest Surgery
    • /
    • v.35 no.2
    • /
    • pp.102-112
    • /
    • 2002
  • This study was undertaken to analyze the outcome of composite valve graftreplacement(CVGR) for the treatment of aneurysms of the ascending aorta involving the aortic root. Material and Method: Between April 1995 and June 2001, 56 patients had replacement of the ascending aorta and aortic root with a composite graft valve and were reviewed retrospectively. Aortic regurgitation was present in 50 patients(89%), Marfan's syndrome in 18 patients(32%), and bicuspid aortic valve in 7(12.5%). The indications for operation were annuloaortic ectasia(AAE) in 30 patients(53.6%), aortic dissection in 13(23.2%), aneurysms of the ascending aorta involving aortic root in 11(19.6%), and aortitis in 2(3.6%). Cardiogenic shock due to the aortic rupture was present in 2 patients. Nine patients(16%) had previous operations on the ascending aorta or open heart surgery. The operative techniques used for CVGR were the aortic button technique in 51 patients(91%), the modified Cabrol technique in 4, and the classic Bentall technique in 1. The concomitant procedures were aortic arch replacement in 24 patients(43%), coronary artery bypass graft in 8(14.3%), mitral valve repair in 2, redo mitral valve replacement in 1, and the others in 7 The mean time of circulatory arrest, total bypass, and aortic crossclamp were 21$\pm$14 minutes, 186$\pm$68 minutes, and 132$\pm$42 minutes, respectively. Result: Early mortality was 1.8%(1/56). The postoperative complications were left ventricular dysfunction in 16 patients(28.6%), reoperation for bleeding in 7(12.5%), pericardial effusion in 2, and the others in 7. Fifty-three patients out of 55 hospital survivors were followed up for a mean of 23.2 $\pm$ 18.7 months(1-75 months). There were two late deaths(3.8%) including one death due to the traumatic cerebral hemorrhage, and CVGR-related late mortality was 1.9%. The 1- and 6-year actuarial survival was 98.1$\pm$1.9% and 93.2$\pm$5.1%, respectively. Two patients required reoperation for complication of CYGR(3.8%) and two other patients required subsequent operations for dissection of the remaining thoracoabdominal aorta. The 1- and 6-year actuarial freedom from reoperation was 97.8$\pm$2.0% and 65.3$\pm$26.7%, respectively.

Early Results of Aortic Valve-sparing Procedures in Patients with Annuloaortic Ectasia (대동맥륜대동맥확장(Annuloaortic Ectasia) 환자에서 대동맥판막을 보존하면서 시행된 대동맥근부 및 상행대동맥 치환술의 단기 성적)

  • Sung Kiick;Park Kay-Hyun;Lee Young Tak;Jun Tae-Gook;Yang Ji-Hyuk;Kim Su Wan;Kim Jin Sun;Cho Sung Woo;Kim Si Wook;Choi Jin Ho;Park Pyo Won
    • Journal of Chest Surgery
    • /
    • v.38 no.7 s.252
    • /
    • pp.483-488
    • /
    • 2005
  • Aortic valve-sparing procedures could reduce valve-related morbidity, but may increase operative risks; therefore, these procedures could not be performed routinely. We attempted to find out the early results while focusing on the operative risks associated with these procedures in our hospital. Material and Method: From May 1996 to July 2003, 26 patients underwent these procedures including 15 patients with Marfan syndrome and 1 patient with Behcet disease. There were 17 men and 9 women with mean age of $37.9\pm19.2$ years (range: 6 months-74 years). Ten patients had ascending aortic dissection, 18 patients had more than moderate degree of aortic valve insufficiency (AI). Two types of valve-sparing procedures were performed: valve reimplantation in 14 and root remodeling in 12 patients. Associated procedures were performed as follows: aortic valve plasty in 6, mitral valve plasty in 5, hemi-arch replacement in 4, total arch replacement in 2, coronary artery bypass surgery in 1 and Maze procedure in 1 patient(s). Result: In four patients, valve-sparing procedures were converted to Bentall procedures during operation. Including these patients, there was no operative deaths, 3 patients underwent re-operation due to bleeding, 1 patient had permanent pacemaker. The median duration of ICU stay was 45.5 hours, the median duration of hospital stay was 10.5 days. In 22 patients excluding 4 converted patients, intraoperative transesophageal echocardiogram (TEE) showed less than mild degree of AI in all except one who had not received intra-operative TEE in the beginning and showed moderate degree of AI at discharge. The mean duration of follow-up was $21.2\pm27.4$ months. All patients were alive except one who died during other departmental surgery. In 3 patients, more than moderate degree of AI was recurred, but there were no reoperation. Conclusion: Aortic valve-sparing procedures could be performed relatively safely in selected patients who had annuloaortic ectasia.

Composite Graft Aortic Root Replacement with Coronary Button Reimplantation: The Early and Mid-Term Results (Composite graft를 이용한 대동맥근부 치환술: Button 술식의 중단기 결과)

  • 나찬영;백만종;김웅한;오삼세;김수철
    • Journal of Chest Surgery
    • /
    • v.35 no.5
    • /
    • pp.356-364
    • /
    • 2002
  • Background: This study was undertaken to investigate the outcome of composite graft aortic root replacement using coronary button reimplantation technique for the treatment of aneurysms of the ascending aorta involving the aortic root. Material and Method: Between April 1995 and September 2001, 54 patients having aortic root replacement with a composite valve graft using direct coronary button reimplantation were reviewed retrospectively. Left ventricular dysfunction was present in 14 patients(25.9%), aortic regurgitation in 48(89%), and Marfan's syndrome in 17(31.5%). The indications for operation were annuloaortic ectasia in 29 patients(53.7%), aortic dissection in 11(20.4%), aneurysms of the ascending aorta involving aortic root in 12(22.2%), and aortitis in 2(3.7%). Six patients(11.1%) had previous cardiac or ascending aortic operations. Concomitant procedures were arch replacement in 21 patients(38.9%), coronary artery bypass graft in 7(13%), mitral valve repair or replacement in 4(7.4%), and others in 6. The mean time of circulatory arrest, total bypass, and aortic crossclamp were 18 $\pm$ 9 minutes, 177 $\pm$ 42 minutes, and 127 $\pm$ 31 minutes, respectively. Result: There was 1 early death(1.9%). Mean follow-up was 24.6$\pm$ 19.5 months. There were two late deaths(3.8%) including one death due to the traumatic cerebral hemorrhage. The Kaplan-Meier survival rate was 98.0 $\pm$ 2.0% and 93.1 $\pm$ 5.1% at 1 and 6 years, respectively. Two patients required reoperation owing to a false aneurysm at the root anastomosis site and a malfunction of prosthetic aortic valve(3.8%). Staged operation for dissection of the remaining thoracoabdominal aorta was performed in 1 patient. The freedom rate from reoperation was 97.8 $\pm$ 2.0% and 65.3 $\pm$ 26.7% at 1 and 6 years, respectively.

Aortic Root Reconstruction for Aortic Insufficiency Developed after Fontal Operation - 1 case - (Fontan 수술후 발생한 대동맥판막역류에 대한 aortic root의 재 건술 - 1례 보고 -)

  • Kyung, Mon-Chol;Whang, Song-Wok;Lee, Chol;Kim, Yung-Jin
    • Journal of Chest Surgery
    • /
    • v.35 no.2
    • /
    • pp.137-140
    • /
    • 2002
  • Aortic regurgitation in the pediatrics who had previous cardiac surgery is increased with their improved longterm survival rate and their complexity of heart disease. So the need of aortic valve surgery in pediatrics is also on the increase. A 10-year old boy was admitted for progressive cyanosis and dyspnea on exertion(DOE). The patient had been underwent lateral tunnel Fontan operation before. Echocardiography and cardiac catheterization study revealed hepatic vein drained to pulmonary atrium via intrahepatic collaterals, moderate atrioventricular regurgitation, and severe aortic regurgitation due to aortic root dilation. We report a case who had aortic root reconstruction, valvuloplasty of the atrioventricular valve, and hepatic vein ligation successfully Cyanosis and DOE was dramatically improved after the operation