• Title/Summary/Keyword: 단지교정

Search Result 35, Processing Time 0.037 seconds

Site Calibration for the Wind Turbine Performance Evaluation (풍력발전기 성능실증을 위한 단지교정 방법)

  • Nam, Yoon-Su;Yoo, Neung-Soo;Lee, Jung-Wan
    • Journal of Industrial Technology
    • /
    • v.22 no.A
    • /
    • pp.49-57
    • /
    • 2002
  • The accurate wind speed information at the hub height of a wind turbine is very essential to the exact estimation of the wind turbine power performance testing. Several methods on the site calibration, which is a technique to estimate the wind speed at the wind turbine's hub height based on the measured wind data using a reference meteorological mast, are introduced. A site calibration result and the wind resource assessment for the Taekwanryung test site are presented using a one-month wind data from a reference meteorological mast and a temporal mast installed at the site of wind turbine. From this analysis, it turns out that the current location of the reference meteorological mast is wrongly determined, and the self-developed codes for the site calibration are working properly. Besides, an analysis on the uncertainty allocation for the wind speed correction using site calibration is performed.

  • PDF

Comparison of Bin Averaging Method and Least Square Method for Site Calibration (단지교정을 위한 빈평균방법과 최소자승법의 비교)

  • Yoo, Neung-Soo;Nam, Yun-Su;Lee, Jeong-Wan;Lee, Myeong-Jae
    • Journal of Industrial Technology
    • /
    • v.25 no.B
    • /
    • pp.157-164
    • /
    • 2005
  • Two methods, the bin averaging method and least square method, are often used in calibrating wind turbine test sites. The objective of this work was to determine a better method to predict the wind speed at wind turbine installing point. The calibration was done at the test site on a complex terrain located in Daegwallyeong, Korea. It was performed for two different cases based on the IEC 61400-12 power performance measurement standard. The wind speeds averaged for 10 minutes ranged between 4 m/s and 16 m/s. The wind-direction bins of each meteorological mast were 10 degrees apart, and only the bins having data measured for more than 24 hours were employed for the test site calibration. For both cases, the two methods were found to yield almost same results which estimated real wind speed very closely.

  • PDF

Introduction to Daegwallyeong Wind Turbine Test Site and Field Test Study (대관령 풍력실증단지 및 실증연구 소개)

  • Yoo Neung-Soo;Nam Yun-Soo;Lee Jung-Wan
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.5-8
    • /
    • 2005
  • This paper aims to introduce the Daegwallyeong wind turbine test site which is the first official wind turbine test site in Korea. The current status of test site, the characteristics, the projects performed and future plan of this test site are described. The results of wind condition measurements and monitoring system established by the Kangwon National University are presented. The importance of field test is also commented.

  • PDF

VD GOGO-구로구청

  • Korea Venture Business Association
    • Venture DIGEST
    • /
    • s.119
    • /
    • pp.12-15
    • /
    • 2008
  • 1980년 영등포구에서 분리된 구로구는 종전 제조업 위주의 구로공단의 칙칙한 이미지로 각인되었다. 하지만 이제 구로는 첨단 벤처단지로 거듭나면서, 디지털 단지를 중심으로 우리나라의 첨단산업을 이끄는 메카로 부상하고 있다. 4대 권역별 균형개발이란 청사진이 완료되면서, 가리봉동 일대 균형발전 촉진지구는 디지털 단지의 배후 기능도시로, 신도림동 일대는 상업복합화를 통해 상권 중심지로, 개봉역 일대는 영등포 교정시설 이전과 주거.문화가 어우러진 복합단지 건설로 생활중심권으로, 서남권 시계지역(오류동, 수궁동 지역)은 수목원과 도시자연공원이 어우러진 전원형 신도시로 변신중이다. 이같은 변화의 주체이며 조력자인 구로구청을 찾아 구로구 소재 중소.벤처기업의 포괄적 마케팅 지원 사업과 해외시장개척단 운영사업, 디지털산업 지원시책을 듣는다.

  • PDF

Surgical exposure of impacted tooth for orthodontic forced eruption : case report (교정적 견인을 위한 매복치의 수술적 노출 방법에 관한 증례보고)

  • Choi, Yongkwan
    • Journal of the Korean Academy of Esthetic Dentistry
    • /
    • v.28 no.2
    • /
    • pp.86-94
    • /
    • 2019
  • Tooth impaction make various problems which are pathologic changes, functional defect and esthetic troubles. Sometimes impacted tooth are extracted. But surgical exposure of impacted tooth and orthodontic forced eruption are usually used a lot to solve these problems. Impacted tooth for orthodontic treatment has two impacted patterns 1) Simple impaction outside alveolar bone covered soft tissue, 2) Fully impaction under alveloar bone. So I introduce way to exposure of impacted tooth for orthodontic treatment with various cases and literatures.

LONG-TERM EVALUATION OF A $SnF_2$ GEL FOR CONTROL OF GINGIVITIS AND DECALCIFICATION IN ADOLESCENT ORTHODONTIC PATIENTS (청소년 교정환자들의 치은염 및 치아탈회 조절을 위해 사용한 겔형 불화주석($SnF_2$ gel)의 장기간 평가)

  • Boyd, Robert L.;Chun, Youn-Sic
    • The korean journal of orthodontics
    • /
    • v.25 no.3 s.50
    • /
    • pp.235-245
    • /
    • 1995
  • The purpose of this paper is to review two recently reported, long-term studies of several chemical methods to control gingivitis and decalcification in adolescent orthodontic patients. The first study(gingivitis study) was designed to determine whether conventional toothbrushing and twice daily use of a brush-on 0.4 per cent $SnF_2$ gel containing more than 90 per cent available $Sn^{2+}$ would be more effective for controlling plaque accumulation and gingivitis in the presence of orthodontic appliances than conventional toothbrushing alone. The second study(decalcification study) was designed to compare the effectiveness of controlling decalcification in orthodontic patients with either a II00 ppm F tooth paste used alone, this same toothpaste and a 0.05 percent NaF rinse or this toothpaste and a 0.4 percent $SnF_2$ gel. In the gingivitis study, sixty-five consecutively treated adolescents who were to receive full-mouth fixed orthodontic appliances were assigned to two groups according to age and sex criteria. In the decalcification study an additional 30 subjects(95 total) were similarly assigned to a third group. The first group(control, n=35) used only toothbrushing with a standard fluoride(1100 ppm F) toothpaste. The second group used toothbrushing with a similar dentifrice supplemented with a 0.4 percent $SnF_2$ gel($SnF_2$ gel group, n=30) used twice daily for the entire 18-month study period. The third group(in the decalcification study only) used a similar toothpaste and 0.05 percent NaF rinse(NgF rinse group, n=30). Clinical assessments of plaque accumulation using the Plaque Index, gingival inflammation using the Gingival Index, and coronal staining were completed single-blinded before appliances were placed and 1, 3, 6, 9, 12 and 18 months after appliances were placed. Decalcification was assessed single blind on all labial surfaces of all erupted teeth before appliances were placed and 3 months after appliances were removed. The results of the gingivitis study indicated that the $SnF_2$ gel gorup had significantly lower scores for the Plaque Index(p<0.01) and Gingival Index(p<0.001) at all examinations during orthodontic treatment than did the control group. In the $SnF_2$ gel group, one subject developed mild coronal staining and two subjects developed moderate staining. In the decalcification study, when pre-treatment levels of decalcification were subtracted from post-treatment values, significantly lower decalcification scores(p<0.05) were found for both whole mouth and first molars in the NaF rinse and gel groups as compared with the control gorup(toothpaste alone). Although the gel group consistently had less decalcification than the rinse group, this difference only approached statistical significance.

  • PDF

A study on the personality characteristics of orthognathic surgery patients through the MMPI. (MMPI를 이용한 악교정 수술환자의 인성에 관한 연구)

  • Park, Woo-Kyoung;Park, Je-Uk;Park, Soo-Byoung
    • The korean journal of orthodontics
    • /
    • v.28 no.5 s.70
    • /
    • pp.741-750
    • /
    • 1998
  • This study was designed to evaluate the Personality characteristics of orthognathic surgery patients preoperatively and postoperatively through the MMPI. Comparison was made between the personality characteritics of preoperative and postoperative groups. Motivation for undergoing orthognathic surgery and postoperative satisfaction were examined through the questionnaire. Subjects used in this study consisted of 50 patients under presurgical orthodontic treatment and 22 patients who had received orthognathic surgery. From this study, the results were followings. 1. In preoperative patients group, all T-scores were within the normal range except for K-scale. The T-score of K-scale is 57.7, this showed that these patients underwent some or less stress. 2. In postoperative patients group, all T-scores were within the normal range. 3. Only in K-scale, there was statistically significant increase after surgery (p<0.05). 4. In male patients group, all T-scores were within the normal range except for that of preoperative K-scale. Postoperatively, there were statistically significant increase in K and Hs scales(p<0.05) 5. In female patients group, all T-scores were within the normal range. 6. Motivation for undergoing orthognathic surgery could be divided into 4 categories. esthetic goal($28.2\%$), functional goal($32.1\%$), TMJ problem($9.0\%$), and psychosocial reason($30.7\%$). 7. The degree of postoperative satisfaction was quite high($85.7\%$). $14.3\%$ of all patients were very satisfied, $71.4\%$ were satisfied, $9.5\%$ were neither satisfied or dissatisfied, and $4.8\%$ were very dissatisfied.

  • PDF

Vision and Aging

  • Kim, In Suk;Hilz, Rudolf
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.7 no.1
    • /
    • pp.9-13
    • /
    • 2002
  • It is well known that the maximum amplitude of accommodation decreases with increasing age.(Presbyopia). With single vision lenses presbyopia can be corrected only for one viewing distance. With progressive power lenses presbyopia can be corrected for all viewing distances. But there are some other changes in the visual system with age which can not be corrected by spectacle lenses. Pupillary diameter decreases and the light transmission of the ocular media decreases. Therefore old people need more light, they need better illumination. Cone density in the retina decreases, this is only one example for changes in the sensory system. These changes in the visual system cause changes in visual functions. At the age of 80 visual acuity has decreased to half. Contrast sensitivity for gratings decreases mainly for high spatial frequencies very important is the increase of stray light in the ocular media and therefore the increase of glare. Veiling luminance increases by a multiple of approximately 4, Dark adaptation gets slower and light sensitivity is approximately 2 log units (factor 100) less when the eye is completely dark adapted. Also colour vision gets worse, especially at low luminances. Elderly people have problems with visual tasks which require divided attention between foveal and peripheral vision. An example is the measurement of the useful field of view. This useful field of view be expanded (improved) by visual training.

  • PDF

A Study on Sewage Characteristics in Hanam City (하남시 오수발생특성에 대한 연구)

  • Choi, Gye-Woon;Hyun, Ji-Hwan;Lee, Ho-Sun
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2005.05b
    • /
    • pp.1317-1322
    • /
    • 2005
  • 하수관거 설계시나 단지개발사업, 그리고 하수관거정비사업과 같이 오수처리시설의 적정 규모 결정을 위해서는 정확한 상수사용량 및 오수발생량 원단위가 요구되지만 국내의 경우 이러한 원단위에 대한 기초자료 부족과 자료의 신빙성 결여로 인해 적정 원단위를 결정하는데 어려움이 있다. 이러한 관점에서 단지개발이 이루어지는 도시에서는 도시의 규모, 입지조건, 기후조건, 생활양식 등 다양한 요인들이 고려된 오수발생패턴 및 발생량 조사가 필요하며, 조사된 원단위는 오수처리시설의 적정 규모 결정뿐 아니라 침입수/유입수 분석 및 하수관거정비에 대한 성과예측에도 활용될 수 있다. 본 연구에서는 현재 단지개발 및 하수관거정비사업이 진행중인 하남시의 표본이 될 수 있는 대표구역을 선정하고 그 지역에서 조사지역을 세부적으로 분류하여 각 지역별 오수발생특성을 분석하였다. 대상지역인 하남시는 총면적의 $97\%$가 자연녹지 및 생산녹지이며, 나머지 $3\%$는 일반주거지역 및 일반 상업지역으로 나뉜다. 그리고 도시계획상 공장지역으로 편성된 부분이 없어 앞으로도 하남시 대부분의 면적이 녹지와 주거/상업지역으로 구성될 것이다. 이러한 하남시의 특성을 고려하여 조사지역은 공장지역을 제외한 일반주거지역, 밀집주거지역, 영업지역으로 분류하였으며 이렇게 분류된 지역은 각각 오수발생패턴 및 오수농도에 대한 조사를 실시하여 오수발생특성을 분석하였고, 조사지역별 인구수 조사와 연계하여 원단위 자료를 추출하였다. 이렇게 조사된 자료들을 통해 침입수/유입수 분석에 요구되는 오수전환율, 야간생활하수량 비율을 산정하였으며, 차후 단지개발 및 관거정비 후에 발생하는 오수 발생특성과 비교분석을 통하여 하남시 지역의 오수발생특성에 대한 신뢰성 있는 자료로 활용될 것으로 기대된다. RMA2 모형을 이용하여 충주댐에서의 물의 흐름을 해석한 결과 옥순대교$\~$청풍대교 구간 사이에 댐 및 지형적 영향으로 인해 잘 발달된 와류가 하도 전체를 통하여 발생되고 있었고 이는 댐 부유물 정체현상이 나타나는 지점과 잘 일치하고 있었다.정함 후 감마분석에 의하여 구하였다. CF:CS 연령모델을 적용한 결과 깊이에 따른 supported $^{210}Pb$와 퇴적 속도는 0.91cm/year 인 것으로 산정 되었다.RS is a more advanced content-based image retrieval system than other systems which support only concepts or image features.방하는 것이 선계기준에 적합한 것으로 나타났다. 밸브 개폐에 따른 수압 변화를 모의한 결과 밸브 개폐도를 적절히 유지하여 필요수량의 확보 및 누수방지대책에 활용할 수 있을 것으로 판단된다.8R(mm)(r^2=0.84)$로 지수적으로 증가하는 경향을 나타내었다. 유거수량은 토성별로 양토를 1.0으로 기준할 때 사양토가 0.86으로 가장 작았고, 식양토 1.09, 식토 1.15로 평가되어 침투수에 비해 토성별 차이가 크게 나타났다. 이는 토성이 세립질일 수록 유거수의 저항이 작기 때문으로 생각된다. 경사에 따라서는 경사도가 증가할수록 증가하였으며 $10\% 경사일 때를 기준으로 $Ro(mm)=Ro_{10}{\times}0.797{\times}e^{-0.021s(\%)}$로 나타났다.천성 승모판 폐쇄 부전등을 초래하는 심각한 선천성 심질환이다. 그러나 진단 즉시 직접 좌관상동맥-대동맥 이식술로 수술적 교정을 해줌으로써 좋은 성적을 기대할 수 있음을 보여주

  • PDF

Establishment of the Monoenergetic Fluorescent X-ray Radiation Fields (교정용 단일에너지 형광 X-선장의 제작)

  • Kim, Jang-Lyul;Kim, Bong-Hwan;Chang, Si-Young;Lee, Jae-Ki
    • Journal of Radiation Protection and Research
    • /
    • v.23 no.1
    • /
    • pp.33-47
    • /
    • 1998
  • Using a combination of an X-ray generator Installed in radiation calibration laboratory of Korea Atomic Energy Research Institute (KAERI) and a series of 8 radiators and filters described in ISO-4037, monoenergetic fluorescent X-rays from 8.6 keV to 75 keV were produced. This fluorescent X-rays generated by primary X-rays from radiator were discriminated $K_{\beta}$ lines with the aid of filter material and the only $K_{\alpha}$ X-rays were analyzed with the high purity Ge detector and portable MCA. The air kerma rates were measured with the 35 co ionization chamber and compared with the calculational results, and the beam uniformity and the scattered effects of radiation fields were also measured. The beam purities were more than 90 % for the energy range of 8.6 keV to 75 keV and the air kerma rates were from 1.91 mGy/h (radiator : Au, filter : W) to 54.2 mGy (radiator : Mo, filter : Zr) at 43 cm from center of the radiator. The effective area of beam at the measurement point of air kerma rates was 12 cm ${\times}$ 12 cm and the influence of scattered radiation was less than 3 %. The fluorescent X-rays established in this study could be used for the determination of energy response of the radiation measurement devices and the personal dosemeters in low photon energy regions.

  • PDF